WESTERMO Ibex-RT-310 Series WLAN Client Bridge Access Point User Manual
- June 9, 2024
- westermo
Table of Contents
WESTERMO Ibex-RT-310 Series WLAN Client Bridge Access Point User Manual
General Information
Legal Information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com.
About This Guide
This guide is intended for installation engineers and users of the Westermo products.
It includes information on safety and regulations, a product description, installation instructions and technical specifications.
Software Tools
Related software tools are available at https://www.westermo.com/support/productsupport.
License and Copyright for Included FLOSS
This product includes software developed by third parties, including Free/Libre Open Source Software (FLOSS). The specific license terms and copyright associated with the software are included in each software package respectively. Please visit the product web page for more information.
Upon request, the applicable source code will be provided. A nominal fee may be charged to cover shipping and media. Please direct any source code request to your normal sales or support channel.
Safety and Regulations
Warning Levels
Warning signs are provided to prevent personal injuries and/or damages to the product. The following levels are used:
Level of warning| Description| Consequence personal injury|
Consequence material damage
---|---|---|---
WARNING| Indicates a potentially hazardous situation| Possible death or
major injury| Major damage to the product
CAUTION| Indicates a potentially hazardous situation| Minor or moderate
injury| Moderate damage to the product
NOTICE| Provides
information in order to avoid misuse of the product, confusion or
misunderstanding| No personal injury| Minor damage to the product
NOTE| Used for highlighting
general, but important information| No personal injury| Minor damage to the
product
Table 1. Warning levels
Safety Information
Before installation:
Read this manual completely and gather all information available on the product. Make sure it is fully understood. Check that your application does not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and installed into an apparatus cabinet or similar, where access is restricted to service personnel only. For Ibex products, outdoor installation is allowed.
During installation, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross-sectional area of at least 4 mm2
Upon removal of the product, ensure that the protective earthing conductor is disconnected last.
HAZARDOUS VOLTAGE
Do not open an energised product. Hazardous voltage may occur when connected to a power supply
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused.
It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
Replacing the internal fuse must only be performed by Westermo qualified personnel.
POWER SUPPLY CONNECTION
There are safety regulations governing the power source that can be used in
conjunction with the product. Refer to chapter Interface Specifications.
RADIO PRODUCTS
Observe the usage limitations of radio products at filling stations, in chemical plants, in systems with explosives or potentially explosive locations.
The product may not be used in airplanes. Exercise particular caution near personal medical aids, such as pacemakers and hearing aids. Never perform work on the antenna system during a thunderstorm.
To fulfill human safety, a minimum separation distance of 20 cm or more should be maintained between the antenna of the product and personnel during operation.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product’s relevant electrical safety standard.
This product complies with Touch Temperature Limits throughout its operational temperature range.
CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to avoid
corrosion attacks on the gold plated connector pins.
CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the cable to
be connected to the field wiring terminals, see chapter Interface
Specifications.
Care Recommendations
Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.
NOTE
Devices not used shall be kept in the factory sealed moisture barrier bag.
Open, unsealed devices should not be kept unpowered for more than 30 days.
Product Disposal
This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.
By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.
Figure 1. WEEE symbol for treatment of product disposal
Compliance Information
REGULATORY NOTICE
Any changes or modifications shall be approved by the party responsible for
compliance. If not, users could void the user’s authority to operate the
equipment. Country code and antenna gain need to be set properly for correct
functionality in the installed country.
Agency Approvals and Standards Compliance
Approvals and Standards
Climate|
- EN 50155, class OT4 Railway applications – Electronic equipment used on rolling stock
- EN 50125-3, Railway applications – Environmental conditions for equipment, Part 3: Equipment for signalling and telecommunications
EMC|
- EN 50155, Railway applications – Electronic equipment used on rolling stock
- EBA EMV 06, German Federal Railway Authority, Radio compatibility of rail vehicles (valid for LV models only)
- EN 50121-3-2, Railway applications – Electromagnetic compatibility, Part 3-2: Rolling stock – Apparatus
- EN 50121-4, Railway applications – Electromagnetic compatibility. Part 4: Emission and immunity of the signalling and telecommunications apparatus
- ETSI EN 301 489-1, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services – Part 1: Common technical requirements
- ETSI EN 301 489-17, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment – Part 17: Specific conditions for Broadband Data Transmission Systems
- ECE E-Mark, Road Vehicles, E13 10R-06 15771 (valid for LV models only)
Mechanical (Shock and vibration)|
- EN 61373, category 1, class A and B
- EN 50125-3, Outside the track
Insulation (Coordination and test)|
- EN 50124-1, Railway applications – Insulation coordination
- EN 50155, Railway applications – Electronic equipment used on rolling stock
Radio communication|
- ETSI EN 300 328, Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques
- ETSI EN 301 893, 5 GHz RLAN
- IEEE802.11, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications
- FCC-47-15, Radio frequency devices
- SRRC certificate (China), Radio Transmission Equipment
Safety|
- EN/IEC 62368-1, Safety Requirements for audio/video, information and communication technology equipment
- EN 45545-2, Fire protection on railway vehicles
- NFPA 130, Fire protection for fixed guideway transit and passenger rail system
United States – FCC
The enclosed product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this product may not cause harmful interference and
- this product must accept any interference received, including interference that may cause undesired operation.
To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this product and persons during operation. To ensure compliance, operations at closer distances than this are not recommended.
This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications
However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the unit and receiver
- Connect the product into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
NOTE
This product contains FCC ID 2AEJD-103902-DT50RF.
NOTE
The Ibex-RT-320-LV is registered for 4.9 GHz public safety band with the FCC
ID 2AEJD-3623-0720
United States – AREMA
The product has been tested according to AREMA Part 11.5.1 environmental class J and C and AREMA Part 11.5.2 exposure class Internal.
Canada – IC
This product complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:
- This product may not cause interference.
- This product must accept any interference, including interference that may cause undesired operation of the product.
NOTE
This product contains the IC Certification number 9301A-103902DT50.
NOTE
The Ibex-RT-320-LV is registered for 4.9 GHz public safety band with the IC
Certification numbers 9301A-36230720
Certified Antennas for FCC and IC
The following antennas can be used with the product (the antenna type ID has to be set to the right value):
Type| Part no.| Manufacturer| Gain| Chains|
Antenna type ID
---|---|---|---|---|---
Dipole| F51-N| Tekfun| 2 GHz: 4.5 dBi max5 GHz: 7 dBi max| 1, 2, 3| 1001
Patch| SPA 2400/75/8/0/V| Huber & Suhner| 2 GHz: 8 dBi max| 1, 2, 3| 1000
Patch| SPA-5600/40/14/0/V_2| Huber & Suhner| 5 GHz: 14 dBi max| 1, 2| 1002
Patch| SPA-5600/65/9/0/MIMO| Huber & Suhner| 5 GHz: 9 dBi max| 1, 2, 3| 1003
Shark| SPA-5600/45/12/10/V| Huber & Suhner| 5 GHz: 12 dBi max| 1, 2| 1004
Shark| SPA-5600/45/12/10/V| Huber & Suhner| 4 GHz: 12 dBi max| 1, 2| 1009
Table 2. Certified antennas for FCC and IC
Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product- support.
Figure 2. The European Conformity and the UK Conformity Assessment markings
Product Description
Product Description
The Ibex-RT-310 and Ibex-RT-320 series can be configured as a WLAN Access
Point, Client or Bridge. It is designed for onboard and infrastructure Wi-Fi
installations in public transport and harsh environments. The 802.11 WLAN
radio is operating at 2.4 GHz and 5 GHz frequency bands.
Figure 3. Ibex-RT-330 block diagram
The Westermo configuration management tool, WeConfig, can be used for discovery and basic configuration and maintenance. The configuration can be done via SNMP or via WebGUI. The status information is available in local LED status indicators, and through SNMP/WebGUI.
The Ibex-RT-310 och Ibex-RT-320 is designed to withstand tough environmental conditions and can be remotely managed using web browser or SNMP management tools. Integrating hardware, software and network design support tools, this router platform offers advanced capabilities, the lowest total cost of ownership and will create the most reliable and resilient networks.
The product is engineered to maintain uninterrupted data communication, even in exceptionally harsh environments. Tested and certified to withstand extreme temperatures, vibrations and shocks, these routers only use industrial grade components which contributes towards a market leading mean time between failure (MTBF), maximized service life, and reduced operational and life cycle costs.
Available models
Art. no.| Model| Region| PoE Port| Rated
current
---|---|---|---|---
3623-071001| Ibex-RT-310-LV EU| Europe| X2| 24 VDC
3623-071002| Ibex-RT-310-LV NA| North America| X2| 24 VDC
3623-072001| Ibex-RT-320-LV EU| Europe| X2| 24 VDC
3623-072002| Ibex-RT-320-LV NA| North America| X2| 24 VDC
3623-072101| Ibex-RT-320-HV EU| Europe| –| 72-110 VDC
3623-072102| Ibex-RT-320-HV NA| North America| –| 72-110 VDC
Table 3. List of available models
Hardware Overview
Frontside Overview
No.| Description| |
---|---|---|---
1| LED indicators| 2| Gigabit Ethernet ports X1 and X2
3| Protective earth terminal| 4| Power input DC
5| Frontside label| 6| Warning symbol for surface temperatures above +60°C
7| Antenna ports A1 to A3| |
Table 4. Location of interface ports and LED indicators
Front Side Label
No. | Description | Remarks |
---|---|---|
1 | Article number | Example of article number |
2 | Serial number | Example of serial number |
3 | Manufacturing date | The Date Format is: YYWW YY = Manufacturing Year WW = |
Manufacturing Week
4| QR code| The data matrix is: AAAAAAAAARR-1-VV-SSSSSSSS-YYWW AAAAAAAAA =
Article numberRR = Region codeVV = Product revision SSSSSSSS = Serial number
YY = Manufacturing Year WW = Manufacturing Week
Table 5. Front side label
Interface Ports View
No. | Description | No. | Description |
---|---|---|---|
1 | Antennas | 2 | 1000Base-T |
3 | Grounding point | 4 | Power |
Table 6. Interface ports view
Connector Information
Power Input Connection
Marking| Position| Direction| Description|
---|---|---|---|---
DC| 1| +DC| Positive terminal| ****
2| –|
3| -DC| Negative terminal
4| –|
Housing| Shield| Chassis of product (ground)
Table 7. M12 A-coded 4-pin male power connector according to IEC 61076-2-101
NOTE
If the product is powered by PoE, the protective dust cap which is part of the
delivery must be closed to protect the power interface from water or dust
ingress
Ethernet Ports
The product includes two Ethernet ports X1 and X2 which supports auto negotiated 10 Mbit/s, 100 Mbit/s and 1000 Mbit/s operation. Automatic MDI/MDIX crossover is supported for 10BASE-T, 100BASE-T, 1000BASE-T operation.
Marking| Position| Direction| Description|
---|---|---|---|---
X1/X2| 1| In/Out| DA+|
2| In/Out| DA-
3| In/Out| DB+
4| In/Out| DB-
5| In/Out| DD+
6| In/Out| DD-
7| In/Out| DC-
8| In/Out| DC+
Housing| Shield| Chassis of product (ground)
Table 8. M12 X-coded 8-pin female Ethernet connector according to IEC 61076-2-109
Position | Device mode A | Device mode B |
---|---|---|
1 | +DC | |
2 | +DC | |
3 | -DC | |
4 | -DC | |
5 | -DC | |
6 | -DC | |
7 | +DC | |
8 | +DC |
Table 9. Ethernet PoE connection on X2 (LV-model only)
NOTE
PoE is supported on X2 for the LV product variant only.
NOTE
If the Ethernet function is not used, the protective dust cap which is part of
the delivery must be closed to protect the interface from water or dust
ingress.
Antenna Ports
The antenna connectors are identified on the product with A1 to A3. QMA industrial standard connector is used.
A1 to A3 are used for WLAN communication. At least A1 must be connected to an external WLAN antenna. The antenna configuration is made through the software interface.
NOTICE
Any unused antenna ports must be properly terminated with 50 Ohm, otherwise
the product might be damaged when power is applied to a non-terminated antenna
port.
NOTE
To ensure specified IP protection, suitable QMA connectors/cables and
terminations must be used.
LED Indicators
- **DC
**
- **OPR
**
- **ERR
**
-
X1
-
**X2
**
Figure 4. LED indicators
LED | Description |
---|---|
DC | Power status |
OPR | Operation status |
ERR | Error status |
X1 | Ethernet status for X1 port |
X2 | Ethernet status for X2 port |
Table 10. LED indicators
NOTE
Refer to management guide for detailed LED status indication.
Dimensions
Dimensions are stated in mm and are regardless of variants.
Figure 5. Dimensional drawing
Installation
Mounting
The product is fixed with the four fixing points located at the corners of the product. M5 or M6 screws are used for the fixation of the product. The screws are tightened with min. 3.0 Nm (fixing screw ISO 898/1, quality class 8.8).
NOTICE
All four specified fixing points must be used for fixing. The installation
surface should be flat to have all fixing points connected to the surface.
NOTE
For indoor installation, consider additional protection against dust to ensure
proper heat dissipation.
NOTE
For outdoor installation, consider additional protection against sun
radiation, dust and dirt to optimize ambient temperature range.
NOTE
Unused connectors must be covered by a protective cap (delivered with the
product), tightened to the specified torque in order to fulfill the specified
ingress protection code.
Factory Reset
To reset the product into factory default settings, a reset adapter is needed which is plugged into one of the Ethernet ports X1 or X2 during startup
Art. no. | Description |
---|---|
3623-0799 | Factory Reset Plug, X-coded |
Factory reset procedure
- Plug the factory reset adapter to one of the Ethernet interfaces.
- Power the product.
- Wait until factory reset adapter is detected. This is indicated by solid ORANGE OPR LED and RED ERR LED.
- Remove factory reset adapter within 15 seconds.
- Successful initiation of the factory reset is indicated by blinking ORANGE OPR LED and RED ERR LED.
Earth connection
For correct function, the earth connection at the grounding point needs to be
properly connected to a solid ground. An M5 grounding screw at the housing is
used for grounding. A short wire with a cross section of at least 4 mm2 shall
be used. The grounding wire is set below the rip-lock washer. The nut is fixed
for good reliable grounding contact. The tightening torque of the nut shall be
2.0 Nm.
Figure 6. Earth connection
NOTICE
Do not use equipment without protective earth connection.
Connection of Cables
Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections are screw connections.
When connecting the power cable, ensure that the pins are connected correctly before tightening the power cable to the unit.
NOTE
This product has no replaceable fuse and should be connected via an external
fuse for protection.
Cooling
This product uses convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the product.
It is recommended to install the product in areas where the natural convection airflow is not blocked and that there is enough spacing around the product.
Figure 7. Installation with reduced natural convection airflow
Figure 8. Installation with natural convection airflow
When operating the product at high ambient temperatures, it is recommended to mount the product to a metallic base plate to improve the heat dissipation. The base plate increases the surface to spread the heat.
Figure 9. Improved heat transfer based on fixing plate and natural
convection
NOTICE
Limited air flow is rising the product temperature and may lower the upper
limit of the operating temperature range.
NOTICE
Temperature is dependent on the operational parameters, like RF output power,
amount of traffic.
NOTICE
This product has integrated temperature sensors for monitoring the internal
device temperatures. If temperature limits are exceeded, alarms are sent
through the SW interface.
NOTICE
The operating conditions shall be ensured so that the normal operation does
not cause temperature alarms. Improve installation conditions or RF parameters
in case of any temperature alarms
Replacement of Product
Disconnect all cables and unscrew the product from the wall. Mount the replacement product and reconnect all cables, observing the instructions in Connection of Cables. MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 10 minutes.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed Touch Temperature Limit
according to the product’s relevant electrical safety standard.
This product complies with Touch Temperature Limits throughout its operational temperature range.
Specifications
Interface Specifications
DC, Power port
| Ibex-RT-310-LV and Ibex-RT-320- LV:| Ibe
x-RT-320-HV:
Connector| M12 A-coded male
Rated voltage| 24 VDC| 72 to 110 VDC
Operating voltage| 16 to 30 VDC| 50 to 138 VDC
Rated current| 0.6 A| 0.2 A
Rated frequency| DC
Inrush current| 39 mA2s at 24 VDC| 4 mA2s at 72 VDC13 mA2 at 110 VDC
Startup current| 2 x rated current
Polarity| Reverse polarity protected
Redundant power input| No
Conductor cross section (flexible)| > 0.5 mm² (AWG 20)
Cable temperature rating| -40 to +70°C
Shielded cable| Not required
PoE (PoE powered product – Ibex-RT-310-LV and Ibex-RT-320-LV only on X2)
Connector| M12 X-coded female
Device mode| A and B
Rated voltage| 48 VDC
Operating voltage| 37 to 57 VDC
Power classification| Class 3
Ethernet TX
Connector| M12 X-coded female
Electrical specification| IEEE std 802.3
Data rate| 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Duplex| Full or half, manual or auto
Transmission range| Up to 100 m with CAT5e cable or better
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
NOTE
The product is to be connected to internal Ethernet networks without exiting a
facility and being subjected to TNVs.
NOTICE
To avoid damages on the Ethernet interfaces, ensure that the far end side of
the Ethernet cable shield itself is connected to protective earth.
Antenna WLAN (A1, A2, A3)
Connector| QMA female
Direction| Transmit and receive
Cabling| 50 Ohm coaxial cable and WLAN antenna required
Conductive chassis| Yes
WLAN interface| High power 3×3 MIMO 802.11n Access Point/Client
WLAN frequency bands| 2.400 to 2.4835 GHz, 4.940 to 4.990 GHz, 5.150 to
5.350 GHz, 5.470 to5.725 GHz, 5.725 to 5.850 GHz
Transmitting power Ibex-RT-310| Max. conducted combined transmit
power within the whole frequency range:802.11b/g/n, up to +18 dBm for all data
rates 802.11a/n, up to +18 dBm for all data rates
Transmitting power Ibex-RT-320| Max. conducted combined transmit
power within the whole frequency range:802.11b/g/n, up to +27 dBm for all data
rates 802.11a/n, up to +27 dBm for all data rates
NOTICE
Depending on the installation country there are frequency/band restrictions
and output power limitations.
NOTICE
Unused antenna port must be terminated with 50 Ohm terminations.
NOTICE
To avoid damages on the antenna interfaces, ensure that the far end side of
the antenna cable and/or the antenna itself is connected to protective earth.
Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| DC power port| ± 2 kV, direct coupling
Ethernet ports| ± 2 kV, capacitive coupling clamp
Antenna ports
Surge| EN 61000-4-5| DC power port| L-E: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs L-L: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs L-L: ±
2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
Ethernet ports| L-E: ± 1 kV, 2 Ω, 18 µF, 1.2/50 µs
Antenna ports
Power frequency magnetic field| EN 61000-4-8| Enclosure| 300 A/m
continues, DC, 16.7 Hz, 50 Hz,60 Hz
Pulsed magnetic field| EN 61000-4-9| Enclosure| 300 A/m
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m, 80% AM (1
kHz) at 80 MHz to 2.7 GHz3 V/m, 80% AM (1 kHz) at 2.7 GHz to 6 GHz30 V/m, PM
200 Hz square at 380 MHz to 385 MHz30 V/m, PM 200 Hz square at 390 MHz to 395
MHz
Conducted RF immunity| EN 61000-4-6| DC power port| 10 V, 80% AM
(1 kHz) from 0.15 to 80MHz
Ethernet ports
Antenna ports
Radiated RF emission| CISPR 16-2-3| Enclosure| Class BFCC Part 15 B,
Class B
Conducted RF emission| CISPR 16-2-1| DC power port| Ibex-
RT-310-LV and Ibex-RT-320-LV: Class B ** Ibex-RT-320-HV: Class A
Ethernet ports
Insulation resistance| EN 50155| Power port (DC) to all other ports| >
100 MOhm
Dielectric strength| EN 50155| Power port (DC) to all other ports| Ibex-
RT-310-LV and Ibex-RT-320-LV: 750 VDC, 60 sIbex-RT-320-HV: 2250 VDC, 60 s
Temperatures| EN 60068-2-1EN 60068-2-2EN 60068-2-14| Operational| -40 to
+70°C (-40 to +158°F)a
**| | Storage and transport| -55 to +85°C (-67 to +185°F)
Humidity| EN 60068-2-30| Operational| 5-95% relative humidity
**| | Storage and transport|
Altitude| | Operational| 3000 m
MTBF| IEC TR 62380| | 370,000 hours
Vibration| MIL STD 810,M514.7 (sine)| Operational| 5 to 10 Hz, 5.08 mm
p-p10 to 200 Hz, 2 g20 sweep cycles in each axis, 0.9 octave/min
**| EN 60068-2-64(random)| Operational, endurance test| 11.44 m/s2 random,
5 to 150 Hz, 3 x 5 h2.3 m/s2 random, 5 to 2000 Hz, 3 x 4 h
Shockb| EN 60068-2-27| Operational| 100 m/s2, 30 ms, 3 x 6 shocks (half
sine)
**| MIL STD 810, M516.7| | 20 g, 11 ms, 3 x 6 shocks (saw tooth)
Weight| | | 1100 gr
Degree of protection| EN 60529| Enclosure| IP66c
Cooling| | | Convection
Pollution degree| EN 62368-1| | PD2
Conformal coating type**| IPC-A-610| Electronic modules| AR (Acrylic)
Refer to “Safety and Regulations” chapter regarding touch temperature
b The power and Ethernet cables need to be fastened 200 mm or closer to the
unit. The same recommendation applies to the Antenna cables. cProvided all
connectors are connected with IP66 cabling or fitted with protective caps
(delivered with the unit) and tightened to the specified torque
Table 12. Environmental and mechanical conditions
Abbreviations and Terms
Abbreviation | Description |
---|---|
AM | Amplitude Modulation |
AREMA | American Railway Engineering and Maintenance-of-Way Association |
AWG | American Wire Gauge |
BPSK | Binary Phase Shift Keying |
CAT5e | Category 5 Enhanced Cable |
CE | Conformité Européenne |
CPU | Central Processing Unit |
DC | Direct Current |
EMC | Electromagnetic Compatibility |
EN | European Standard |
ERR | Error |
ESD | Electro Static Discharge |
ETSI | European Telecommunications Standards Institute |
FCC | Federal Communication Commission |
FLOSS | Free/Libre Open Source Software |
HV | High Voltage |
IEC | International Engineering Consortium |
IC | Industry Canada |
ID | Identification |
I/O | Input / Output |
IP | Ingress Protection |
ISO | International Standardization Organisation |
LAN | Local Area Network |
LED | Light Emitting Diode |
LV | Low Voltage |
MIMO | Multiple Input, Multiple Output |
MTBF | Mean Time between Failure |
MTTR | Mean Time to Repair |
OPR | Operation |
PM | Pulse Modulated |
PoE | Power over Ethernet |
QMA | Quick-connect RF Connectors |
QR | Quick Response |
RF | Radio Frequency |
TNV | Telephone Network Voltage |
SN | Serial Number |
SNMP | Simple Network Management Protocol |
VPN | Virtual Private Network |
WebGUI | Web Graphical User Interface |
WeConfig | Westermo Configuration Tool |
WEEE | Waste Electrical and Electronics Equipment |
WLAN | Wireless Local Area Network |
Table 13. Abbreviations and terms
Revision Notes
Revision | Date | Change description |
---|---|---|
Rev. H | 2022-12 | 2.5.2 Agency approvals updated; SRRC certificate added, |
removed old chapter 3.3. Rear Side Label.
Rev. G| 2021-10| (User guide migrated to CMS tool), 2.2 Safety Information;
information on cooling moved to chapter 4.5 Cooling, 2.5.1 Agency Approvals
and Standards Compliance updated, 3.3.2 Front Side Label; callouts reversed
order, 3.5 Led Indicatiors; illustration added, 4.2 Factory Reset moved from
old chapter 3.6, 4,5 Cooling; illustrations updated.
Rev. F| 2021-06| 3.4.2 Updated (D-code > X-code)
Rev. E| 2021-05| Regulatory statements updated for public safety band in
chapter 2.5.2, 2.5.4, 2.5.5 and table 13. Note in chapter 2.3 updated.
Rev. D| 2021-03| Product illustrations updated to blue, text in illustrations
removed, Westermo address updated, chapter 2.5.5 updated
Support
Westermo Metallverksgatan 6, SE-721 30 Västerås, Sweden Tel +46 16 42 80 00
Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Product support, user guides and software downloads ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>