GEORGE KOVACS P2264-084-L Double Take 150-Watt Equivalence Integrated LED Brushed Nickel Pendant Installation Guide

May 21, 2024
GEORGE KOVACS

GEORGE KOVACS logo P2264-084-L Double Take 150-Watt Equivalence
Integrated LED Brushed Nickel Pendant
Installation Guide

 P2264-084-L Double Take 150-Watt Equivalence Integrated LED Brushed

Nickel Pendant

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

MOUNTING THE FIXTURE (Fig. 1)

  1. Shut off power at the fuse box or circuit breaker box. If necessary remove the existing fixture and its mounting hardware.

  2. Carefully remove the new fixture from the carton and check that all parts are included as shown in the illustration.

  3. Rotate rings (R) and (Q) to the desired positions.

  4. Attach mounting plate (C) to junction box (A) (not included)using mounting screws (E) (Size: #8-32*1/2”L). The side of the mounting plate marked “GND” must face out.

  5. Determine the desired hanging height and thread rods (K2and K1) to all thread on top of fixture body (M). Attach canopy(J) by screwing onto rod (K1). Carefully pass the wires through each rod during assembly. Note: Remove all thread if installing with one 6” rod only.

  6. There are two drivers inside the canopy, connect driver output wire to LED wire with wire nuts (F) as below:
    -Red driver output wire (labeled 350mA Output+) to red LED wire (labeled 350mA LED+)
    -Black driver output wire (labeled 350mA Output-) to black LED wire (labeled 350mA LED-)
    -Red driver output wire (labeled 450mA Output+) to red LED wire (labeled 450mA LED+)
    -Black driver output wire (labeled 450mA Output-) to black LED wire (labeled 450mA LED-)
    CONNECTION THE WIRES (Fig. 2)

  7. Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box (A) has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly  to the mounting plate (C) using the green screw provided. After the wires are connected, tuck them carefully into the junction box (A).
    FINISHING THE INSTALLATION (Fig. 1)

  8. Align canopy (J) to mounting plate (C) and secure with screws (G).
    Your installation is now complete. Return power to the junction box and test the fixture.
    CAUTION / ATTENTION: When handling the fixture, donor apply pressure to the LEDs. Hold the fixture byte base or fixture body only.

Dimmable with ELV and/or LED compatible wall dimmer switch.

Fig. 1
A-021-125D for P2264-084-L
-Mounting plate (C)
-Ground screw (N)
-Mounting screw*2 (E)

GEORGE KOVACS P2264 084L Double Take 150 Watt Equivalence Integrated LED
Brushed Nickel PendantGEORGE KOVACS P2264 084L Double Take 150 Watt
Equivalence Integrated LED Brushed Nickel Pendant - fig

IMPORTANT: Fixture should be installed by a qualified electrician to ensure proper wiring and installation.