ECCOTEMP 7GB-LP Whole Home Tankless Hot Water Heater Instruction Manual
- June 1, 2024
- Eccotemp
Table of Contents
- ECCOTEMP 7GB-LP Whole Home Tankless Hot Water Heater
- AUTOMATIC INSTANTANEOUS WATER HEATER
- Use & Care Manual
- Tankless Water Heater
- ___
- ___
- IMPORTANT SAFETY INFORMATION
- INSTALLING THE 7GB WATER HEATER
- CLEARANCES FOR OUTDOOR WATER HEATER INSTALLATION LOCATIONS
- PERFORMANCE FEATURES
- PRODUCT DIMENSIONS
- TECHNICAL DATA AND DIMENSIONS
- WATER HEATER INSTALLATION
- PLUMBING NOTES
- CONNECTING THE WATER
- CONNECTING THE GAS
- PRESSURE AND GAS LEAK TESTING
- PRESSURE RELIEF VALVE
- CONNECTING THE ELECTRIC
- REMOTE CONTROLLER
- REMOTE CONTROLLER INSTALLATION
- INITIAL OPERATION
- NORMAL OPERATION
- NORMAL OPERATION WITH MULTIPLE REMOTES
- MAINTENANCE AND SERVICE
- TROUBLESHOOTING
- PCB ERROR CODES
- THE FOLLOWING CONDITIONS ARE NOT A FAULT
- WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ECCOTEMP 7GB-LP Whole Home Tankless Hot Water Heater
7 GB BUILDER SERIES OUTDOOR MANUAL
WHOLE HOME TANKLESS HOT WATER HEATER INSTALLATION, USE AND CARE INSTRUCTIONS
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
- WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliances.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
AUTOMATIC INSTANTANEOUS WATER HEATER
Use & Care Manual
With Installation Instructions for the Installer
Tankless Water Heater
WARNING! This water heater may not be suitable for use in manufactured (mobile) homes! Please check local code restrictions pertaining to permanent/fixed installations in manufactured homes in your area. The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, to the owner-operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list. It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you don’t understand these instructions or any terms within it, seek professional advice.
- Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on If You Need Service.
- Do not destroy this manual. Please read carefully and keep in a safe place for future reference.
- Recognize this symbol as an indication of Important Safety Information!
- California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
- WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY!
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury, or death. Refer to this manual.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
DO NOT store or use gasoline or other flammable vapors or liquids or other
combustible materials in the vicinity of this or any other appliance. To do so
may result in an explosion or fire.
- WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliances.
- DO NOT touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- DO NOT return to your home until authorized by the gas supplier or fire department.
FOR YOUR RECORDS
Write the model and serial numbers here:
___
___
You can find them on a label on the water heater and/or packaging.
Staple sales slip or canceled check here.
Proof of the original purchase date is needed to obtain service under the
warranty.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your water
heater properly. A little preventive care on your part can save you time and
money over the life of your water heater. You’ll find many answers to common
problems in the Troubleshooting Guide. If you review the chart of
Troubleshooting Tips first, you may not need to call for service.
READ THE SAFETY INFORMATION
Your safety and the safety of others are very important. There are many
important safety messages in this manual and on your water heater. Always read
and obey all safety messages. This is the safety alert symbol. Recognize this
symbol as an indication of Important Safety Information! This symbol alerts
you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER”, “WARNING”, “CAUTION” or “NOTICE”.
These words mean:
- DANGER – An imminently hazardous situation that will result in death or serious injury.
- WARNING – A potentially hazardous situation that could result in death or serious injury and/or damage to property.
- CAUTION – A potentially hazardous situation that may result in minor or moderate injury.
- NOTICE – Attention is called to observe a specified procedure or maintain a specific condition.
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
Be sure to read and understand the entire Use and Care Manual before
attempting to install or operate this water heater. It may save you time and
money. Pay particular attention to the Safety Instructions. Failure to follow
these warnings could result in serious bodily injury or death. Should you have
problems understanding the instructions in this manual, or have any questions,
STOP, and get help from a qualified service technician, or the local gas
utility.
DANGER!
PROPERLY INSTALL WATER HEATER
Failure to properly install the water heater OUTDOORS as outlined in the
Installation Instructions in this manual can result in unsafe operation of the
water heater. To avoid the risk of fire, explosion, or asphyxiation from
carbon monoxide, never operate this water heater unless it is installed
properly and has an adequate air supply for proper operation. Be sure to
inspect the flue terminal for proper installation at initial start-up; and at
least annually thereafter. Refer to the Care and Cleaning section of this
manual for more information regarding flue terminal inspection.
WARNING!
Gasoline, as well as other flammable materials and liquids (adhesives,
solvents, paint thinners etc.), and the vapors they produce are extremely
dangerous. DO NOT handle, use or store gasoline or other flammable or
combustible materials anywhere near or in the vicinity of a water heater or
any other appliance. Be sure to read and follow the labels on the water
heater, as well as the warnings printed in this manual. Failure to do so can
result in property damage, bodily injury or death.
DANGER!
WATER TEMPERATURE SETTING
Safety and energy conservation are factors to be considered when selecting the water temperature setting. Water temperatures above 125°F can cause severe burns or death from scalding. The thermostat is adjusted to its lowest temperature position when shipped from the factory. Be sure to read and follow the warnings outlined on the label pictured below.
Water temperature over 125°F can cause severe burns instantly or death from scalds. Children, disabled and elderly are at highest risk of being scalded. See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available, see manual.
Time/Temperature Relationship in Scalds
- The chart shown above may be used as a guide in determining the proper water temperature for your home
- DANGER! Households with small children, disabled, or elderly persons may require a 120°F. or lower temperature setting to prevent contact with”HOT” water.
- Maximum water temperature occurs while burner is on. To find water temperature being delivered, turn on a hot water faucet and place a thermometer in the water stream and read the thermometer.
- The temperature of the water at the outlet of the water heater can be regulated by setting the temperature on Remote Control. The remote control was set at 110°F before it was shipped from the factory.
- The illustration to the bottom left illustrates the Remote Control and how to adjust the water temperature.
- NOTICE: When this water heater is supplying general purpose hot water requirements for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a
- licensed plumber or the local plumbing authority for further information.
- NOTICE: The factory recommended operating temperatures are between 90°F and 140°F.
DANGER!
NATURAL GAS AND LIQUEFIED PETROLEUM MODELS
Both liquid propane gas (LPG) and natural gas (NG) have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LPG or NG, ask the gas supplier. Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak. Always check with commercial leak detector or soapy water.
- Gas detectors are recommended in LPG and NG applications and their installation should be in accordance with the detector manufacturer’s recommendations and/or local laws, rules, regulations or customs.
- Water heaters utilizing LPG are different from NG models. A NG water heater will not function safely on LPG and vice versa.
- No attempt should ever be made to convert the water heater from NG to LPG. To avoid possible equipment damage, personal injury or fire, do not connect the water heater to a fuel type not in accordance with the unit data plate; propane for propane units and natural gas for natural gas units. These units are not certified for any other fuel type.
- LPG water heaters should not be installed· below grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or customs.
- Propane or LPG must be used with great caution. It is heavier than air and will collect first in lower areas making it hard to detect at nose level.
- Before attempting to light the water heater, make sure to look and smell for gas leaks. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect a gas leak, be sure to sniff near the floor also.
- It is recommended that more than one method, such as soapy solution, gas detectors, etc., be used to detect leaks in gas applications.
Notice: If a gas leak is present or suspected:
- DO NOT attempt to find the cause yourself.
- DO NOT try to light any appliances.
- DO NOT touch any electrical switch.
- DO NOT use any phone in your building.
- Leave the house immediately and make sure your family and pets leave also.
- Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire department.
- Stay away from the house (or building) until the service call has been made, the leak is corrected and a qualified agency has determined the area to be safe.
WARNING!
For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, electric shock, or to prevent property damage,
personal injury, or loss of life.
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
California Law requires that residential water heaters must be braced,
anchored or strapped to resist falling or horizontal displacement due to
earthquake motions.For residential water heaters up to 52 gallon capacity, a
brochure with generic earthquake bracing instructions can be obtained from:
Office of the State Architect, 400 P Street, Sacramento, CA 95814 or you may
call 916-445-8100 or ask a water heater
dealer.
However, applicable local codes shall govern installation. For residential
water heaters of a capacity greater than 52 gallons or tankless style, consult
the local building jurisdiction code for acceptable bracing procedures.
SAFETY PRECAUTIONS
Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary. Turn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off.
- Read this manual entirely before installing or operating the water heater.
- Use this water heater only for its intended purpose as described in this Use and Care Manual.
- Be sure your water heater is properly installed in accordance with local codes and the provided installation instructions.
- Part of your water heater unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY
SAVE THESE INSTRUCTIONS
This water heater must be installed in accordance with these instructions, local codes, utility company requirements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 North Capitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as NFPA 54. In Canada, the latest edition of the CSA B149.1 Natural Gas and Propane Installation, and the Canadian Electrical Code, CSA. C22.1Part1, in the absence of local codes.
INSTALLING THE 7GB WATER HEATER
Location
-
This water heater is for OUTDOOR installation ONLY!
-
Make sure before installation that the gas type you will use is the same type on the data plate.
-
The water heater unit should be installed by professionals from your local gas company. Please don’t attempt installation by yourself. Improper installation may cause failure or dangerous conditions such as gas leaking or explosion.
-
This water heater is an outdoor model and must be mounted on a vertical wall. It must not be installed indoors or in a confined space. The water heater should be installed close to the most frequently used outlet and its position chosen with safety and service in mind.
-
Make sure people (particularly children, disabled, and elderly) will not touch the hot water outlet or the flue terminal. The flue terminal and air inlet must be clear of obstruction and shrubbery.
-
If installed in a public corridor, please assure that the surrounding area is free of debris, obstruction and flammable materials.
-
The unit must be installed on a fire retardant area, and must be away from all flammable materials. Clearance should be 1.75 ft to the left and right side of flammable materials, and 6.75 ft to the front.
-
The unit should be installed in open area where strong currents are not prevalent
-
This unit is of high power and will consume a lot of oxygen when working, so the installation area must be well ventilated, and air in and out of the area has no blockage.
-
The outdoor unit should not be installed in a corridor with rooms on the both sides or in the closed corridor.
-
Take measures to avoid direct wind, rain and snow. The installation area should be constructed of fire retardant materials. The power socket connecting the water heater should be properly grounded.
-
The water heater must be located so it is not subject to physical damage, for example, by moving vehicles, area flooding, etc.
-
The water heater must be installed vertically with the water, gas, and power connections on the underside, pointing toward the ground.
-
Failure to properly install the water heater outdoors as outlined in this manual can result in unsafe operation.
-
Hot and cold water lines should be insulated to conserve water and energy.
-
DO NOT install water heater where subject to vibrations.
-
DO NOT install the water heater in Recreational Vehicles, Mobile Homes, Boats and other Watercraft.
-
DO NOT install the water heater near vents for heating or cooling. A minimum of 4 feet should be maintained.
-
If the clearances stated on the Instruction/Warning Label, located on the front panel of the heater differ, install the water heater according to the clearances stated on the label.
-
WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible and/or flammable products
and materials should never be stored in the vicinity of this or any gas appliances. -
WARNING: The 7GB is to be installed outdoors only. In some climates the ambient air temperature will fall below the temperature in which water freezes 32°F / 0°C. DO NOT use the 7GB water heater in unsafe freezing conditions because it could damage the water heater or cause other property damage. Make sure that all components and controls are suitable for use in the current temperature before using.
Proper operation of the water heater requires air for combustion and ventilation. Provisions for combustion and ventilation air must comply with referenced codes and standards.
Combustion and Ventilation Air
This water heater is for OUTDOOR installation ONLY.
It must NOT be installed indoors or in a confined space.
NOTICE: The water heater should not be installed near an air supply containing halogenated hydrocarbons.
Corrosive Atmospheres
- The air in beauty shops, dry cleaning establishments, photo processing labs, and storage areas for liquid and powdered bleaches or swimming pool chemicals often contain halogenated hydrocarbons.
- An air supply containing halogenated hydrocarbons may be safe to breathe, but when it passes through a gas flame corrosive elements are released that will shorten the life of any gas burning appliance.
- Propellants from common spray cans or gas leaks from A/C and refrigeration equipment are highly corrosive after passing through a flame.
- The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere.
Inspect Shipment
Inspect the water heater for possible damage. Check the markings on the rating
plate of the water heater to be certain the type of gas supplied corresponds
to the water heater requirements. Verify all included parts are present (see
below).
CLEARANCES FOR OUTDOOR WATER HEATER INSTALLATION LOCATIONS
- Clearance in accordance with local installation codes and the requirments of the gas supplier.
- A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings.
- Permitted only if veranda, porch, deck, or balcony is fully open on a mimimum of two sides beneath the floor.
- This water heater is strictly forbidden to be installed indoors and in the bathroom.
- The water heater shall not be installed under the exhaust fan of the exhaust fan or range hood.
- There shall be no other gas appliances near the installation of the water heater, and there shall be no flammable gasses, liquid, etc. around it.
- Installation of outdoor water heaters should avoid the impact of others people’s lives due to exhaust and noise.
- The water heater must be installed in a well ventilated area (eg. open balcony, patio). The distance between the water heater and the surrounding wall (mm).
- For clearances not specified in ANSI Z223.1/NFPA 54 or CSA-B149.1, one of the following shall be indicated:
A) A minimun clearance value determined by testing in accordance with Clause 5.20, or;
B) A reference to the following footnote:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.”
† A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings and serves both dwellings ‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Notes:
- In accordance with the current CSA B149.1 Natural Gas and Propane Insallation Code
- In accordance with the current ANSI Z223.1 / NFPA 54 Nationa Fuel Gas Code
PERFORMANCE FEATURES
This product is a forced type gas water heater. When powered on the waste gas will be forced to exhaust outside under the help of the draught fan.
Rain proof outdoor gas water heater
Its rain proof design helps to stop the rain from dropping into the water
heater. The water heater inhales air from outside to burn and exhaust the gas
waste to outside, the user can operate the water heater through a remote
control.
Temperature control system controls and coordinates the water, electricity,
and gas to make sure the outlet water temperature is consistent.
Low start up water pressure.
Flame-out protection, if the water heater flames out suddenly, it will cut off
the gas automatically to make sure a gas leak does not occur.
WARNING
The water heater has an automatic draining function. When the water inlet
pressure of the water heater exceeds 145 psi – 174 psi, the water heater will
automatically drain. Please do not place objects around the water heater to
avoid damage caused by water immersion of the water heater. When the water
heater automatically drains the water, it indicates that the water system
pressure is too high. After the pressure is reduced or the water valve is
closed, confirm that the pressure meets the requirment for using the water
heater.
NOTES
- The appliance will operate at reduced performance below 49 psi water pressre.
- For information relating to burner test point pressures and injector sizes refer to the name plate located on the right hand side of the case for each model.
- For information relating to overall dimensions and connection point refer to diagrams.
- Installing in areas over 1 mile above sea level will reduce performance.
PRODUCT DIMENSIONS
NOTICE: The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See (NFGC) for complete instructions. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions.
TECHNICAL DATA AND DIMENSIONS
WATER HEATER INSTALLATION
Mark the wall with a dark mark, then drill three holes with a diameter of 8mm
and a depth of 2 3/4 inch, then insert three 1/4 x 2 inch expansion screws
into the hole and tighten the screws with a wrench.
Hang up the water heater, screw on the 1/4 inch nut and fix the heater to the
wall.
Incorrect installation of the heater will affect the normal use of the water
heater.
PLUMBING NOTES
- When connecting the hot water supply to the fixtures of the property a minimum of 6.5ft of pipe work must be used between the outlet of the water heater and first outlet (shown below).
- The hot water line should be insulated with pipe insulation.
- When the installation is completed the temperature is to be tested at the outlet to confirm the water temperature does not exceed the required 122°F (50°C) setting.
- Water pipe size is nominal 1/2 inch from hot water outlet to the first outlet.
- Gas pipe size in nominal 3/4 inch.
CONNECTING THE WATER
- All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for potable water systems.
- A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater.
- Only a gate valve or a ball valve is to be used on the cold water supply.
- Check the cold water pressure. If above 145 psi an approved limiting valve must be fitted.
- Before installing the water heater, flush the water line to remove all debris, and after installation complete, purge the air from the line. Failure to do so may cause damage to the heater.
- To prevent water heater water system damage caused by excessive pressure. At the water outlet of the water heater, it is necessary to install an appropriate pressure relief valve to protect the water system and user safety. The pressure relief valve complies with ANSIZ21.22/CSA 4.4
- In the hot water system, the temperature rises continuously, and the volume of water expands.
- If the system is equipped with an expansion tank or a flexible connection bellows can absorb a part of the expansion amount, the expansion tank or the soft connection bellows cannot absorb the pressure relief valve needed to protect the pressure relief valve to protect The entire system prevents breakage of pipes and other components, so the relief valve pressure setting is generally selected to be slightly less than the maximum pressure (Pmax) that the entire system can withstand.
- In addition, the pressure cannot be the same as the normal operating pressure, too close to the normal operation of the pressure relief valve will frequently pressure relief, lower temperature and pressure relief valve service life.
- In order to prevent the damage of the temperature probe or control system and cause the continuous heating of hot water to reach 212°F (100°C) vaporization, it is necessary to install a temperature and pressure safety valve, and the temperature and pressure
- valve temperature reaches 210°F (99°C) to relieve the pressure, thereby protecting the entire system. So the safety valve temperature is generally set to 210°F (99°C).
- There is a wire mesh filter to discourage debris from entering your heater. Clean filter after initial installation to ensure no debris from the pipe work has clogged it.
CONNECTING THE GAS
SIZING AND CONNECTION SUITABILITY
- Check the gas type label to make sure that the unit was built for the type of gas you will be using, and that the gas inlet pressure is within the appropriate range.
- Gas pressure below the specified range for the water heater and/or insufficient gas volume will adversely affect performance.
- Inlet gas pressure must not exceed the maximum values, gas pressure above the specified range will cause dangerous operating conditions and damage the unit.
- Until testing of the main gas line supply pressure is completed, ensure the gas line to the water heater is disconnected to avoid any damage to the water heater. Always use approved connectors to connect the unit to the gas line. Always purge the gas line of any debris before connecting to the water heater.
- Install a manual gas shut-off valve between the water heater and the gas supply line.
- The regulator is preset to factory standards. It is computer controlled and is not to be adjusted by any person other than a licensed professional.
- When the gas connections are completed, perform a gas leak test either by applying soapy water to all gas fittings and observing for bubbles or by using a gas leak detection device.
PRESSURE AND GAS LEAK TESTING
- Shut off the manual gas valve on the supply gas line.
- Open a tap/outlet. The unit should turn on and the air in the gas pipeline should be purged.
- Leave the tap/outlet running until the unit shuts down due to lack of gas supply. Then turn off the tap/outlet.
- Remove the screw on the pressure port located on the gas inlet of the water heater shown in the diagram to the right.
- Connect the manometer to the pressure port.
- Re-open the manual gas valve. Check to see that there are no gas leaks.
- Open some of the fixtures that use a high flow rate to turn on the water heater.
- Check the inlet gas pressure in the postiton shown in the circle above. When the heater is at maximum capacity, the gas pressure point must be within the appropriate range.
PRESSURE RELIEF VALVE
- Please use sealant tape to seal the thread of pressure relief valve, then install it into Tee valve G3/4 outlet (as shown above).
- Please use sealant tape to seal the thread of the water outlet, then install pressure relief valve, tee valve and water outlet together. Please select a suitable position to install (as shown above).
- Please note that the outlet of the pressure relief valve cannot face upward, otherwise it will never fully drain.
- Anti-fouling and anti-scaling, dirt will directly affect the normal function of the safety valve function. The drain pipe must match the drain port to ensure that the valve does not interfere with the normal operation of the valve.
- The pressure relief valve outlet can be installed horizontally or vertically, do not install the pressure outlet facing upwards, otherwise it cannot work normally. It is forbidden to block its outlet.
- The dirt will directly affect the normal function of the safety valve function. It requires hot water system maintenance of anti-fouling and anti-scaling cleaning.
- The user must check the relief valve at least once a year. When checking, turn off the water heater’s power supply and gas. Turn on the water inlet switch to create pressure in the water system. Then gently open relief valve handle until there is water coming out and then gently close it, if there is no water coming out, this indicates that the valve is invalid, immediately turn off the water heater switch and contact support at support@eccotemp.com
- Before operating the handle, check the discharge line connecting the valve to ensure that the water drained from the valve can be drained to a suitable place.
WIRING DIAGRAM
CONNECTING THE ELECTRIC
- The water heater must be electrically grounded. Do not attach the ground wire to either the gas or water piping.
- The water heater requires an AC 120V 60Hz.
- The weather-proof power point should be no more than 3ft. from the base of the water heater for easy access.
- Install a power switch so that the electrical power can be switched off if necessary.
- If the cord supplied with this appliance must be replaced, it must be replaced with the correct appliance wiring material supplied by the Manufacturer.
- When servicing or replacing parts within the water heater, label all wires prior to disconnection to facilitate an easy and error free reconnection. Verify proper operation after servicing.
Warning
Turn off the electric power to the water heater and manual gas valve located
on the outside of the unit before beginning gas connection
Confirm the postition of the gas inlet. Do not connect water line to gas
inlet.
Warning
Conversion of this unit from natural gas (NG) to propane (LPG) or LPG to NG
cannot be done in the field. Contact your supplier to get the correct unit for
your gas type.
CHECK THE WATER HEATER
After the installation of the water heater is completed, it is necessary to
check that the water heater has no air leakage, water leakage, or gas leakage,
and the ignition operation is normal, and there is no fault alarm.
REMOTE CONTROLLER
- The water heater can be installed with up to three remote controllers. Each remote controller has two functions which can adjust the set temperature and indicate the error code.
- PRIORITY function: The controller that is activated first (i.e. button is pressed) is given PRIORITY function, and can freely adjust the temperature. Remaining controllers will display the set temperature however will not be able to make any adjustments. After a 15 minute period of inactivity the priority on the first remote will cease and priority can then be assigned to another remote by activating it (i.e. a button is pressed). Then the new controller has priority and the cycle repeats.
- Default setting temperature: At the initial power on, the setting temperature will be the same as the value set on DIP switch. After the initial use, it will remember the former setting temperature. All water heater models have self diagnostic function for safety and convenience when troubleshooting. If there is a problem with the installation or the unit, it will display a numerical error code on the remote controller (or the LED of the computer board will be blink.)
Remote controller installation requirements
The remote controllers are splash resistant, however should not be positioned
where it can be splashed directly & should be appropriately sealed between the
surface of the wall & controller.
The remote controller can be installed in the bathroom provided it is
correctly installed.
Remote controllers output temperature setting (158°F (70°C) mode)
The remote controller is able to adjust the output temperature in the range of
95°F (35°C) to 158°F (70°C) in one degree increments.
REMOTE CONTROLLER INSTALLATION
The remote controller comes with a 25 ft. cable. If a longer cable is needed, please purchase a shielding line. Cut the original line and rewire according to the polarity to avoid short circuit whilst adhering to the requirements below:
- a. Minimum 18 AWG wire
- b. Maximum run of 98.5 ft.
Attach the remote control to the wall with screws supplied.
WIRING CONTROLLER TO THE WATER HEATER
- Turn off the power supply to the water heater.
- Connect the first controller only and turn on the power supply to the water heater.
- Turn off the first controller by pressing the on/off button (LED light will turn off).
- Continue to connect any additional remote control wires to the remote terminals directly.
- DO NOT jump or short-circuit wires otherwise the PCB may become damaged.
- Return the front cover.
- DO NOT turn on the remotes until instructed.
- Activate the first remote by pressing & holding the ‘cool’ (down arrow) button for 5 seconds until a single beep sounds. Then press & hold the ‘heat’ (up arrow) button for 5 seconds until the LED screen lights up.
- Adjust the on screen value to set the ID (available ID’s include -0, -1, -2). Press the on/off button to confirm (The ID of the remote control cannot be repeated).
- Repeat for all additional controllers.
- Controllers can now be turned on and will operate as per the PRIORITY function.
INITIAL OPERATION
FOR YOUR SAFETY, READ BEFORE OPERATING:
- Check the GAS and WATER CONNECTIONS for leaks before startup for the first time.
- Open the main gas supply valve to the unit using only your hand to avoid any spark. Never use tools. If the knob will not turn by hand, do not try to force it. Forced repair may result in a fire or explosion due to gas leaks.
- Check the GAS PRESSURE.
- Do not try to light the burner manually. It is equipped with an electronic ignition device which automatically lights the burner.
- Check for PROPER VENTING and COMBUSTIBLE AIR to the heater. Purge the GAS and WATER LINES to remove any air pockets.
- Do not use this water heater if any part has been submersed under water.
NORMAL OPERATION
- Turn on the power switch.
- After confirming power is on, press the remote control power button “ ”
- Open the inlet water valve and gas valves.
- Open the water valve (hot water tap), the water heater will ignite and work, and hot water will flow out.
- During the operation of the water heater, if the power supply suddenly stops, the water heater will stop working and close the gas valve. When the power is reset, the water heater with the remote control can be started by the remote control, and the water heater without the remote control can be started after re opening the water.
- Power failure before operation, the water heater cannot start to provide hot water service.
NORMAL OPERATION WITH MULTIPLE REMOTES
Press the ON/OFF button. The Power light will become lit on the remote
controller with setting temperature displayed on each of the remote
controllers. The controller with priority function will have a lashing Power
light.
Set the required temperature using the Cool & Heat Buttons. (The temperature
setting can only be changed by the priority controller).
Open a hot water tap, and ensure the Burner ON light is lit. Mix cold water
with the hot as required. Close the hot water tap. The Burner light will turn
off.
FREEZE PREVENTION
Only the pipes and heat exchanger inside the water heater heater will be
protected.
Any hot or cold water pipes located outside of the unit will not be protected.
Proper protection and insulation of these pipes will be required to ensure
these are protected from freezing.
- Turn water OFF.
- Turn gas OFF.
- Turn OFF the power supply.
- Drain water.
- WARNING! If freezing conditions are expected, turn off water and gas and drain all water from the appliance. If power and the automatic frost protection are connec ted freezing will be prevented.
- NOTICE! When freezing temperatures persists consult with a licensed installation professional for winterization of your product.
- NOTICE! Eccotemp recommends all termination hoods have a backflow preventer to assist with freezing air. Consult with an installation professional for proper installation.
- NOTICE! During power outages built in freeze protection will not be activated. Take proper steps to ensure your water heater doesn’t freeze.
MAINTENANCE AND SERVICE
- The water heater should be checked at least once a year or as necessary by a licensed technician.
- If repairs are needed, any repairs should be done by a licensed technician. The water heater’s lifetime may be extended by regular maintenance.
- Clean the cold-water inlet filter (refer to diagram below).
- Be sure that all openings for combustion air are not blocked. If blocked, remove obstruction. Check that the opening for exhaust is not blocked. If blocked, shutoff the water heater’s combustion and then after a while, remove obstruction.
- DO NOT touch while unit operating, otherwise you might get burnt due to high temperature. Check the gas pressure.
- Keep the area around the water heater clear. Remove any combustible materials, gasoline or any flammable vapors and liquids.
UNIT DRAINING AND FILTER CLEANING
- Close the manual gas shut off valve.
- Turn off the power supply to the water heater. Close the manual water shut off valve.
- Open all hot water taps in the house (Bathroom, kitchen, laundry, etc.). When the residual water flow has ceased, close all hot water taps.
- Have a bucket or container to catch the water from the unit’s drain plugs. Unscrew the drain plugs to drain all the water out of the unit.
- Wait a few minutes to ensure all water has completely drained from unit.
- Clean the filter: Check the water filter located within the cold inlet. With a tiny brush, clean the water filter of any debris which may have accumulated and reinsert the filter back into the cold water inlet. Securely screw the drain plugs back into place. Hand-tighten only.
TROUBLESHOOTING
PCB ERROR CODES
Troubleshooting :
When the water heater fails, the display will display the fault code, while
the buzzer will continuously issue a “Beep” alarm sound, please follow the
table to deal with accordingly
If any codes appear in the chart above and the water heater is functioning normally, restart the water heater. After restarting and it is not operating normally, please notify the after-sales service staff maintenance.
THE FOLLOWING CONDITIONS ARE NOT A FAULT
WARNING
- Service shall be carried out only by authorized personnel and the appliance shall not be modified;
- The appliance must be installed, commissioned and serviced by an authorized person in accordance with the requirements;
- For continued safety of this appliance it must be installed, operated and maintained in accordance with the manufacturer’s instructions.
WARRANTY
Eccotemp Systems ,LLC Limited Warranty Information
Model (s): 7GB NG/LP Portable Tankless Water Heater
I. LIMITED WARRANTY
Subject to the terms below, Eccotemp Systems, LLC (“Eccotemp”) provides this
limited warranty (the “Limited Warranty”) to cover the following Products and
Covered Components:
This Limited Warranty is being provided to the original purchaser and subsequent owners (the “Owner”), but only while the Product remains as the site of the original installation.
II. LIMITED WARRANTY PERIOD
The term of this Limited Warranty (the “Warranty Period”) begins on the date
of purchase and ends as set forth below:
5 YEAR WARRANTY
The covered components, except for the Heat Element, in the Product are
warranted by Eccotemp for a period of five (5)
years from the date of purchase when installed according to Eccotemp’s
Installation and Operating Instructions.
10 YEAR WARRANTY
The Heat Exchanger in the Product is warranted by Eccotemp for a period of ten
(10) years from the date of purchase
when installed according to Eccotemp’s Installation and Operating
Instructions.
30 DAY WARRANTY
All accessories that have been provided with the Product at no cost are
warranted by Eccotemp for a period of thirty (30)
days from the date of purchase when installed according to Eccotemp’s
Installation and Operating Instructions.
If, during the Warranty Period, a component in the Product fails because of a
manufacturing defect, Eccotemp will repair, replace, or refund the Product to
the Owner at Eccotemp’s sole discretion and as determined to be appropriate by
the Eccotemp Support Team. As set forth in Section IV, the Owner may be
responsible for all shipping, freight, and handling charges, as well as all
fees and costs associated with the warranty service, including, but not
limited to, all labor and other costs involved in diagnostic calls or in
removing, repairing, servicing, or replacing any component. Eccotemp’s sole
responsibility under this Limited Warranty is to repair, replace, or refund
the cost of the Product at Eccotemp’s sole discretion. In the event that an
exact replacement component is no longer available, Eccotemp will, at its
option, provide a substitute component that Eccotemp deems suitable for the
Product. If the Owner reports a subsequent issue with any covered component in
the Product,
surrender the component(s) at the request of Eccotemp.
Both Eccotemp and the Owner of the Product are bound by this Limited Warranty.
IV. MAKING A WARRANTY CLAIM
To make a warranty claim through this Limited Warranty, the Owner must contact
Eccotemp’s Customer Service team at support@eccotemp.com, schedule a call or
live chat on the Eccotemp support page at http://support.eccotemp.com,. It is
within Eccotemp’s sole discretion when a repair, replacement, or refund will
be issued. Any return for refund must be approved by Eccotemp’s Customer
Service team prior to shipping the Product back to Eccotemp. Please refer to
Returning Your Product For Repair or Refund Policy provided with the Product.
purchase, the Owner is responsible for all shipping to Eccotemp, regardless of
reason or circumstance. Eccotemp will cover the warranty related shipping
costs when returning the Product to the Owner after repair/inspection. The
method for warranty related shipping will be ground equivalent with the
provider within Eccotemp’s sole discretion.
What information you will need for processing of your warranty claim:
- Proof of purchase
- Serial number
- Photos of the installation
- Photos of the damage point (if there is one)
All shipments of any type of product coming to Eccotemp for any reason must
have a Return Goods Authorization (“RGA”) number for any repairs to be made.
Please contact Eccotemp to obtain an RGA number prior to shipping anything to
Eccotemp. Failure to do so could result in loss of Product. Eccotemp will not
be responsible for replacement due to loss or damage if these steps are not
properly followed.
Any returns to Eccotemp must be sent in the original packaging. If your
returned product does not have the original packaging and/or is missing any of
the components that came with the product, there will be a nonnegotiable 15%
restock fee.
Eccotemp Systems ,LLC Limited Warranty Information
Model (s): 7GB NG/LP Portable Tankless Water Heater
V. DISCLAIMER OF WARRANTIES AND RESPONSIBILITY FOR DAMAGES
EXCEPT AS PROVIDED IN THIS LIMITED WARRANTY, ECCOTEMP MAKES NO WARRANT -Y,
EXPRESS OR IMPLIED, TO ANY ONE AS TO FITNESS FOR ANY PURPOSE, MERCHANTABILITY,
DESIGN, CONDITION, CAPACITY, PERFORMANCE, OR ANY OTHER ASPECT OF THE PRODUCT
OR ITS MATERIAL OR WORKMANSHIP. ALL IMPLIED WARRANTIES WHICH MAY EXIST,
NOTWITHSTANDING THIS DISCLAIMER, ARE LIMITED TO THE DURATION OF THIS LIMITED
WARRANTY. THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER GUARANTEES,
WARRANTIES, REPRESENTATIONS, C -ONDITIONS, OBLIGA TIONS, OR LIABILITIES,
EXPRESS OR IMPLIED.
ECCOTEMP SHALL NOT BE LIABLE, EITHER IN CONTRACT OR TORT, FOR ANY DIRECT,
INDIRECT, INCIDENT- AL OR CONSE QUENTIAL DAMAGES, OR ANY LOSS, DAMAGE, OR
INJURY TO PERSONS, INCLUDING DEATH, PROPERTY, OR THINGS, OR FOR DAMAGES OF ANY
KIND OR NATURE INCLUDING BUSINESS INTERRUPTION, INCONVENIENCE OR L- OSS OF
ANTIC IPATED PROFITS OR SAVINGS OCCASIONED BY OR ARISING OUT OF THE USE,
MISUSE, NONUSE, REPAIR, REPLACEMENT OR DELAY IN DELIVERY OF THE PRODUCT.
ECCOTEMP SHALL NOT BE LIABLE FOR THE COST OF ANY WORK DONE BY PURCHASER OR
OTHERS TO THE PRODUCT.
warranties or incidental or consequential damages. In such jurisdictions, the
limitations or exclusions do not apply to the Owner. The Owner may also have
other rights that may vary by jurisdiction.
EXCLUSIONS
The following exclusions apply to this Limited Warranty:
- A repair, replacement, or refund will not be provided under this Limited Warranty unless the Product containing the defective component is properly installed and maintained according to Eccotemp’s Installation Manual and Use & Care Manual and in compliance with all applicable federal, state/province, and local laws, regulations, codes, policies, and licensing requirements. Any abuse, misuse, alteration, neglect, or misapplication of the Product will render this Limited Warranty null and void.
- A repair, replacement, or refund will not be provided if the Product is damaged by services performed by third party service providers other than Eccotemp Systems.
- Eccotemp systems is not responsible for any expenses arising from labor services, including but not limited to, installa-tion or removal services due to a warranty claim.
- A repair, replacement, or refund will not be provided if the Product is used in a hot water circulation loop, in series with a circulation system, where an on-demand recirculation system is incorporated, or in any other corrosive or otherwise destructive environment where the Product is not intended to be used as set forth in Eccotemp’s Installation Manual and Use & Care Manual.
- A repair, replacement, or refund will not be provided if the Product is damaged as a result of improper installation,
- A repair, replacement, or refund will not be provided if the Product is damaged as a result of improper use, including freezing within the unit or surrounding piping, incorrect sizing for the application, scale build up, or incorrect gas and/or water pressure.
- This Product shall not be used as a pool or spa heater. Use of the Product as a pool or spa heater shall be considered misuse and will render this Limited Warranty null and void.
- A repair, replacement, or refund will not be provided if the Product is damaged by the use of non-potable, untreated or poorly treated well water, or water with high PH levels or hardness levels in excess of 12 grains per gallon (200 mg/L).
- A repair, replacement, or refund will not be provided under this Limited Warranty if the original serial number on the Product has been removed or altered in a way that causes the serial number to not be readily determined.
- Eccotemp will not pay electricity or fuel costs, or increases in electricity or fuel costs, for any reason whatsoever, in-cluding additional or unusual use of supplemental electrical heat.
- Eccotemp will not be responsible for any default or delay in performance under this Limited Warranty caused by any factor or contingency outside of its control.
MISCELLANEOUS
No agent, employee or representative of Eccotemp has any authority to bind
Eccotemp to any representation or warran-ty concerning the Product not
contained in this Limited Warranty. Eccotemp reserves the right and authority
to change, modify or alter this warranty at any given time.
FOR CUSTOMERS WITH A HOME WARRANTY
Often your home warranty will assist in covering some of the fees related to
your home appliances, such as your water heater. Be sure to check with your
home warranty company for assistance prior to reaching out to Eccotemp.
315 A Industrial Road, Summerville, SC 29483 | 1-866-356-1992
© Eccotemp 2022 All Rights Reserved | Printing Version 1.3
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>