FANMASTER IMF-600 Axial Misting Fan Instruction Manual
- June 17, 2024
- Fanmaster
Table of Contents
FANMASTER IMF-600 Axial Misting Fan
Product Information
Specifications:
- Model: IMF-600
- Power: 800W
- Speed: 910 rpm
- Air flow: 160 m3/min
- Air pressure: 90 Pa
- Noise: 70 dB
- Oscillating angle: 90 degrees
- Misting volume (Max): 10 L/h
Assembly Instructions:
- Do not plug in the fan before assembly. Carefully remove all packaging materials, making sure there is no residual foam left in any of the components. Check all components for shortage or damage during transportation.
- Assembling Tank Cart:
- Refer to diagram 1. Loosen two M8 bolts and take out the oscillation device.
- Refer to diagram 2. Assemble the left supporter and right supporter on the tank cart with M8 bolts.
- Assembling Oscillating Device And Handle:
- Refer to diagram 3. Assemble the oscillating device on the top of the left and right supporters and fix it with M16 bolts and M16 hand wheel.
- Refer to diagram 4. Assemble the handle inside the left and right supporters with the M6 screw.
- Settling Water Tank: Place the water tank on the tank cart (refer to diagram 5).
- Assembling Misting Fan And Electric Box:
- Refer to diagram 6. Place the misting fan on the oscillation connect panel and lock it with an M8 bolt.
- Refer to diagram 7. Fix the electrical box behind the horizontal plate using M6 screws. Connect the two-core male and female connectors of the water pump and the four-core male and female connectors of the oscillating device. Lock the nut and connect the upper blue water pipe to the lower end of the regulating ball valve.
Cautions
- When opening packing box, please take the machine head out as per direction sign.
- Don’t insert hands or any objects into the machine guards and misting plate.
- The upward and downward angle of the machine must be adjusted within stated angle range.
- Don’t put the machine close to curtain and other easily sucked in objects
- Don’t put the machine on uneven place.
- Children,elders and weak people can’t stand in front of the machine for a long time.
- Type Y attachment – Damaged supply cords to be replaced by the manufacturer,service agent or similarly qualified person to avoid hazard.
- Please cut off the power and send the machine to qualified technician to check if the running machine emit unusual noise,smoke or machine blade can not run after power supply.
- Except for maintenance scope, an unprofessional person should not dissemble repair or rebuild the machine.
- Take away non-humidity-proof objects when starting the mist function in order to avoid causing rusty or damage to the objects.
- The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Maintenance
- In order to keep the machine durable, you should clean the machine timely.
- Please cut off the power before cleaning and remove the front guard and blade. Clean the machine with soft cloth, ( please don’t use gasoline or other corrosive liquid ) please dry the guard and blade with dry cloth,then install the machine.( Attention:mist plate inside misting system can’t be dissembled ).
- Please don’t let water flow into the motor and wet electric elements during cleaning, also don’t press/bend the blade and change the pitch angle of the blade.
- In order to keep the water clean in water tank, please wash the water tank, and water-receiving plate at a proper time.
- To ensure machine can oscillate smoothly, please add grease oil to the rotary part of the oscillating mechanism every 6 months.
- Please clean the machine and seal the whole machine with a plastic bag before long time storage of the machine.
Feature And Application
- Utilize CAD-optimized design , good and graceful looking.
- Centrifugal misting system means no nozzles and filter water, with reasonable structure and simple maintenance.
- The fan surface is epoxy resin coated, anti-rust and durable. The fan electrical components are designed to be waterproof. Safe to use, with tank cart, easy to move.
- Air supplying, misting and oscillating functions are driven by different motors. Motors adopt high quality ball bearings, with advantages of stable, low temperature-rise, long service life, low noise, and strong overloading ability.
- The misting function is controlled by an independent switch, with good misting effect and adjustable misting volume.
- A fan is equipped with independent control oscillation device . Convenient and reliable for use.
- Designed for cooling, dedusting and deodorizing in factories, residential areas, shopping malls , athletic fields, livestock farms, greenhouses, paper mills, tobacco factories and more.
Operating Instructions
- Apply the fan complied to the voltage and frequency shown on the rating label. Do not use in corrosive environment.
- When socket is used in power supply, the socket should meet the IEC335-1 standard. When power liner is from direct power supply, a polarity switch should be installed with contact gap not less than 3mm on the fixation wiring.
- Oscillating angle adjustment: Loosen hand wheels on the fan left side and right side. Move it to the desired angle and tighten hand wheels.
- Make sure two casters locked and tank is filled with certain amount of water before using the misting mode.
- Filled with certain amount of water, then connect the power supply of the fan and press the fan button to run the fan motor. Press misting button to run misting motor and water pump. By pressing oscillating button, the fan will automatically oscillate.
- Misting adjustment between “OFF” and “ON” when the fan runs with misting .
- The fan can operate continually for 8 hours with the maximum misting volume when the fan runs with misting . Re-fill the tank to achieve the misting effect when it is short of water.
- In the use of water tank cart, DO NOT force to push the tank cart before opening the bake of the caster. Close the bake of the caster when stopping the tank cart. DO NOT stop the tank cart at the slope to prevent sliding forward.
- Clean the tank each time before use. Take out the water pump before clean . Pour out the water after clean.
- Press the misting button to cut off the power supply between misting motor and water pump, and the fan can be used for blowing.
Wiring Diagram
remark:we don’t notify you if above technology parameter change
Assembly Instructions
Do not plug in the fan before assembly. Carefully remove all packaging materials, make sure there is no residual foam left in any of the components. Carefully check all components, make sure there is neither shortage nor damage during transportation.
Assembling Tank Cart
- a. Refer to diagram 1. Loosen two M8 bolts and take out oscillation device.
- b. Refer to diagram 2. Assemble left supporter and right supporter on tank cart with M8 bolts.
Assembling Oscillating Device And Handle.
- a. Refer to diagram 3. Assemble the oscillating device on the top of the left and right supporters, and fix it with M16 bolts and M16 hand wheel.
- b. Refer to diagram 4. Assemble the handle inside the left and right supporters with the M6 screw.
Settling Water Tank
Refer to diagram 5. Place the water tank on tank cart.
Assembling Misting Fan and Electric Box
- a. Refer to diagram 6. Place the misting fan on the oscillation connect panel and lock by M8 bolt.
- b. Refer to diagram 7. Fix the electrical box behind the horizontal plate with M6 screws. Connect the two-core male and female connectors of water pump and the four-core male and female connectors of oscillating device. Lock the nnut, and connect the upper blue water pipe to the lower end of the regulating ball valve.
Misting Testing
- a. Fill the water tank with appropriate clean water and lid the tank cover and lock casters.
- b. Turn the misting ball valve from ON to OFF. Start the fan by pressing fan switch and check if fan motor and fan blade run normally.
- c. Press the misting button to start the misting motor and water pump and check if the misting motor, misting plate and water pump run normally.
- d. Turn the misting ball valve from OFF to ON to check the misting condition .
- e. Press the oscillation button to to check if the fan head oscillates smoothly.
Product Dimension
Structure Diagram
- Safety grill
- Misting plate
- Water outlet
- Water gathering plate
- Supporter of water gathering plate
- Misting motor
- Front grill
- Water collection plate
- Drum
- Motor supporter
- Fan motor
- Blade
- Rear grill
- Pushing Handle
- Left fan supporter
- Right fan supporter
- Electric box
- M16 Hand wheel
- horizontal plate
- Extension pipe
- Oscillation connect panel
- Oscillation device
- Water tank cover
- Water tank
- Front caster
- Tank cart
- Rear caster
- Water pump
References