FANMASTER ASP-500-MF2 Masterfilter Air Scrubber Purifier Instruction Manual

June 12, 2024
Fanmaster

FANMASTER ASP-500-MF2 Masterfilter Air Scrubber Purifier

FANMASTER-ASP-500-MF2-Masterfilter-Air-Scrubber-Purifier-
PRODUCT

Product Information

The Fanmaster Masterfilter air scrubber purifier is an industrial-grade appliance designed to remove particles from the air and surrounding surfaces, as well as eliminate odors. It features a two-stage filtration process that captures 99.97% of airborne particles, including dust, allergens, bacteria, and viruses. The appliance is equipped with a UV-C light sterilization a function that deactivates the DNA of microorganisms, preventing their ability to multiply and spread. The ASP-500-MF2 model has a rated power of 0.21KW and operates on AC220-240V/50Hz. It has an airflow rate of 241 L/s (CFM) and a noise level of 78 dBa. The appliance weighs 15.5 kg and has dimensions of (W)438x(D)328x(H)412 mm.

Product Usage Instructions

  1. Safety Precautions: Before using the appliance, carefully read and understand all the safety rules and warnings provided in the instruction manual.

  2. Disposal Guidelines: Do not dispose of the product with general household waste. Follow the laws governing Waste Electrical and Electronic Equipment for proper disposal. Contact local authorities for information on disposal
    facilities.

  3. Assembly: Remove the appliance from the carton. If any damage is observed, contact Fanmaster or the place of purchase for assistance.

  4. Filter Assembly: Open the cover by releasing the two latches. Remove the plastic packaging from all filters. Failure to do so may cause risks or damage to the appliance.

  5. Operation: Place the appliance in the desired location. Connect the appliance to a suitable power source using the provided 3-pin plug. Ensure the cable length is appropriate for your setup.

  6. Working Principle: The ASP-500-MF2 draws contaminated air into the air inlet, which then passes through a two-stage filtration process. The first stage involves the G4 Pleated Disposable Cardboard Filter, which captures initial dust
    and allergen particles. The second stage utilizes the H13 HEPA Filter, which captures smaller particles up to 0.3 microns and helps control bacteria and mold growth. After filtration, the UV-C Light sterilizes the filtered air by deactivating microorganisms’ DNA.

  7. Air Outlet: The clean, filtered air is expelled back out through the air outlet.

  8. Filter Replacement Indicator: The appliance is equipped with a filter replacement indicator light that illuminates when the HEPA filter needs to be replaced. Monitor this indicator and replace the filter accordingly.

For further details on product usage, maintenance, and troubleshooting, refer to the complete instruction manual provided with your purchase. Keep this document for future reference. TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS & INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS

FOR YOUR INFORMATION

Thank you for purchasing a Fanmaster Masterfilter air scrubber purifier. Please read this instruction manual carefully before using this appliance.

Disclaimer
Fanmaster reserves the right to make alterations to specifications, quantities, and dimensions, for production or other reasons, subsequent to publication. While we believe the information is accurate and complete, we make no warranty or representation for any particular purpose. The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user.

Disposal Guidelines
Do not dispose of this product with general household waste. This product must be disposed of according to the laws governing Waste Electrical and Electronic Equipment. If required, contact your local authorities for information regarding the available disposal facilities.

GENERAL SAFETY RULES & WARNINGS

  • PLEASE READ THE INSTRUCTIONS CAREFULLY.
  • PLACE THE INSTRUCTION MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. DO NOT ALLOW ANYONE WHO HAS NOT READ THESE INSTRUCTIONS TO ASSEMBLE, ADJUST OR OPERATE THIS APPLIANCE.
  • IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT IN CAUSING PROPERTY DAMAGE, SERIOUS INJURY OR LOSS OF LIFE.
  • FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS APPLIANCE, CAN RESULT IN DEATH, SERIOUS INJURY, AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, AND/OR ELECTRICAL SHOCK.
  • ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS APPLIANCE. IF YOU NEED ASSISTANCE OR REQUIRE INFORMATION SUCH AS AN INSTRUCTION MANUAL, LABELS, ETC. CONTACT FANMASTER.
  • DO NOT STORE OR USE GASOLINE, PETROL OR ANY OTHER FLAMMABLE OR COMBUSTIBLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE.
  • THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE IS CONNECTED MUST COMPLY WITH LOCAL REGULATIONS. A RESIDUAL-CURRENT DEVICE (RCD) MUST BE INSTALLED.
  • UNPLUG THE APPLIANCE BEFORE PERFORMING ANY MAINTENANCE OPERATIONS.
  • ALWAYS CHECK THE POWER CABLE BEFORE USING THE APPLIANCE. IT MUST NOT BE BENT, TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED.
  • IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A SERVICE AGENT OR A QUALIFIED PERSON.
  • DO NOT LEAVE THE APPLIANCE UNATTENDED WHEN IN USE.
  • NEVER USE THE APPLIANCE WITH WET HANDS OR WHEN EITHER THE APPLIANCE OR THE POWER CABLE IS WET.
  • CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.
  • THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE & KNOWLEDGE.
  • PLEASE MAKE SURE ALL PLASTIC PACKAGING IS REMOVED FROM ALL FILTERS BEFORE OPERATION.
  • THIS APPLIANCE CONTAINS A UV EMITTER. DO NOT STARE AT THE LIGHT SOURCE.
  • DO NOT USE AN ADAPTER WITH THIS APPLIANCE.
  • BREATHING HAZARD – WHEN USING THIS APPLIANCE IN A CONTAINMENT AREA, ALWAYS TURN OFF POWER TO OPEN COMBUSTION APPLIANCES SUCH AS FIREPLACES, FURNACES, WATER HEATERS & HVAC SYSTEMS TO AVOID THE RISK OF BACK-FLOW CARBON MONOXIDE FUMES.
  • IF THE FILTER CHANGE LIGHT ILLUMINATES DURING THE REMEDIATION PROCESS, IMMEDIATELY CHANGE THE HEPA/ACTIVATED CARBON FILTER.
  • TIPPING HAZARD – ONLY STACK THIS UNIT IN STORAGE, NOT IN USE. DO NOT STACK MORE THAN TWO (2) UNITS ON TOP OF EACH OTHER.
  • THIS APPLIANCE IS NOT DESIGNED TO BE CONTINUOUSLY USED 24 HOURS 7 DAYS A WEEK AS IT WILL SHORTEN THE PRODUCT LIFE.

PRODUCT DESCRIPTION & SPECIFICATIONS

PRODUCT DESCRIPTION
Industrial air scrubber purifier designed to remove particles from the air and surrounding surfaces and odors.

SPECIFICATIONS

MODEL ASP-500-MF2
Air Flow (L/s) (CFM) 241
Rated Power 0.21KW
Voltage (V/Hz) AC220-240V/50
Current Rating (A) 0.87
Plug Connection 3 Pin 10amp
Cable Length (m) 5

Filters

| 1st stage: G4 Pleated Disposable Cardboard Filter 2nd stage: H13 HEPA Filter

UV-C Light Sterilisation

Filter Size (mm)| Pre Filter: 290x290x22 H13: 280x280x105
Fan Dia (mm)| 220
Air outlet Dia (mm)| 197
Filtered Aream (m2)| up to 40
Fan Speed| Variable
Hour Meter| Yes
Filter Replacement/Clean Indicator Light| Yes
Noise (dBa)| 78
Weight (kg)| 15.5 / 17
Product Dimensions (mm)| (W)438x(D)328x(H)412
Packaged Dimensions (mm)| (W)505x(D)390x(H)465

  • When the unit’s total working time adds up to 2000 hours, the filter warning light will flash with an alarm on the control panel. (To reset the machine, push the UV-C light switch 3 times continuously in 5 seconds after Resetting the filter service time)
  • UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work, the alarm will keep ringing.

GETTING TO KNOW YOUR APPLIANCE

FANMASTER-ASP-500-MF2-Masterfilter-Air-Scrubber-Purifier-
FIG-1

HOW IT WORKS

The ASP-500-MF2 works by drawing the contaminated air into the air inlet which passes through a 2-stage filtration process that removes 99.97% of airborne particles and is then sterilized with a UV-C Light. The clean filtered air is then expelled back out via the air outlet. It removes dust particles and other airborne contaminants that carry mold spores, germs, and viruses from the air and surrounding surfaces. The ASP-500-MF2 is fitted with a filter replacement indicator which will light up when the HEPA filter needs to be replaced.

Two (2) stage filtration & UV-C Light process
1st Stage: Pre-filter G4 Pleated Disposable Cardboard Filter – captures initial dust & allergen particles.
2nd Stage: H13 HEPA Filter – captures even smaller particles, up to 0.3 microns. Helps control and prevent the growth of bacteria and mold. Capturing 99.97% of dust & allergen particles.
UV-C Light : UV-C Light sterilizes the filtered air. UV-C technology works by deactivating the DNA of microorganisms like bacteria & viruses disrupting their ability to multiply & spread.

USES & APPLICATIONS

USES

  • Air purification
  • Dust control
  • Odor control
  • Remediation & Restoration works (water, fire & mold damage)

APPLICATIONS

  • Constructions sites
  • Offices
  • Commercial – hotels, kitchens
  • Warehouses, workshops, factories
  • Rental/Hire

ASSEMBLY & OPERATING INSTRUCTIONS

Remove the appliance from the carton. If the appliance is damaged, please contact Fanmaster or where you purchased the appliance from.

ASSEMBLY

There is minimal assembly required. REMOVE PLASTIC PACKAGING FROM FILTERS – open the cover by releasing the two (2) latches and remove the plastic packaging from all filters. Failure to do so will cause risks or damage to the appliance. The appliance will not work.

OPERATING INSTRUCTIONS

  1. Place the appliance so that it is in an upright vertical position (placed on the rubber feet).
  2. Connect the plug to the relevant power source.
  3. Open the air inlet cover on the opposite side of the control panel (filters)
  4. Turn the appliance on by turning the Variable Speed Control.
  5. To turn the appliance off turn the Variable Speed Control anti-clockwise.

CONTROL PANEL
Variable Speed Control – controls the airflow (clockwise to increase) Hour Meter – indicates the running time of the unit

FANMASTER-ASP-500-MF2-Masterfilter-Air-Scrubber-Purifier-
FIG-2

UVC On/Off – controls the UV-C Lamp
Change HEPA Filter – indicates when to replace/clean the HEPA Filter

CLEANING, MAINTENANCE & STORAGE

  • Before starting any maintenance task, shut down, and unplug the appliance.
  • Do not attempt any electrical repair yourself. If the appliance needs service or repair, contact a qualified person.
  • When cleaning, make sure that water does not enter the unit.
  • Do not open the enclosure to clean the inner parts. Do not spray water into the appliance.
  • Never use solvents, gasoline, toluene, and similar aggressive chemicals to clean the appliance.

Regularly wipe the enclosure using a soft sponge or cloth. For very dirty parts, use a sponge wetted with lukewarm water and a mild detergent, then dry using a clean cloth. Clean or replace the filters as required. Check the power cord and plug for any damages, if damaged replace the cord or plug immediately by a qualified person only.

STORAGE

  • Clean the unit before storing it for long periods of time.
  • Keep stored inside.
  • Maximum stack of 2 units.

WIRING DIAGRAM

FANMASTER-ASP-500-MF2-Masterfilter-Air-Scrubber-Purifier-
FIG-3

TROUBLESHOOTING

PROBLEM CAUSE SOLUTION

No Power

| Plug is loose or not connected correctly| Check plug connection
Faulty or damaged power cord| Check & replace
No air flow| Filters are blocked| Replace filters
Air inlet or outlet is blocked| Check for bloackages
UV-C Lamp not working| Drain pipe is clogged| Clean out drain pipe
Faulty| Replace
Not positioned correctly| Check placement

  • When the unit’s total working time adds up to 2000 hours, the filter warning light will flash with an alarm on the control panel. (To reset the machine, push the UV-C light switch 3 times continuously in 5 seconds after Resetting the filter service time)
  • UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work, the alarm will keep ringing.

WARRANTY

Any claim under this warranty must be made within 12 months of the date of purchase of the product. To make a claim under the warranty, take the product (with proof of purchase) to the store where you purchased the product or go to https://www.fanmaster.com.au/support.
This warranty is given by Fanmaster Pty Ltd
ABN: 45 353 934 457
Unit 1/6-8 Yalgar Rd, KIRRAWEE NSW 2232
P: 1300 900 345
E: support@fanmaster.com.au

This warranty is provided in addition to other rights and remedies you have under the law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Exclusions: This warranty does not cover:

  • Any defects caused by an accident, misuse, abuse, improper installation or operation, lack of reasonable care, unauthorized modification, loss of parts, tampering, or attempted repair by a person not authorized by the distributor.
  • Any product that has not been installed, operated, or maintained to a satisfactory level.
  • Any damage caused by improper power input or improper cable connection.

Fanmaster Pty Ltd | 1/6-8 Yalgar Road, KIRRAWEE NSW 2232
1300 900 345 | sales@fanmaster.com.au | www.fanmaster.com.au

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals