Richmond RMTG70DVLN-3 Non-Condensing Tankless Gas Water Heaters
Product Information
Specifications
- Gas Input Rate (BTU/h): 11,000 – 199,900
- Uniform Energy Factor (UEF): 0.82 – 0.95
- Number of Bathrooms: 2-4
- Minimum Activation Flow: 0.4 GPM
- Maximum Altitude: 7,800 ft.
- Warranty: 15 Year Heat Exchanger | 5-Year Parts | 1-Year Labor
- Height: 20.75″ – 24.2″
- Width: 13.5″
- Depth: 9.4″ – 10.27″
- Venting Diam. Allowed: 3 by 5 CONCENTRIC
- Controls: Built-in digital display
- Power Supply: 120V 60Hz
- Gas Connection: 3/4 NPT
- Hot Water Connection: 3/4 NPT
- Cold Water Connection: 3/4 NPT
Product Usage Instructions
Installation
The Richmond water heaters are designed for easy installation and are suitable for retrofits. Follow the detailed installation instructions provided in the user manual to ensure proper setup.
Gas Connection
Make sure to connect the gas line using a 3/4 NPT connection for a secure and leak-free installation.
Water Connections
Connect the hot and cold water lines using the provided 3/4 NPT connections to ensure a steady flow of water.
Venting
Use venting materials allowed such as 3-in./5-in. UL-approved Category III Stainless Steel vent materials or manufacturer-approved vent material for safe operation.
Maintenance
Regular maintenance is essential for optimal performance. Refer to the user manual for maintenance guidelines and schedule regular check-ups.
Frequently Asked Questions
- Q: Can I use this water heater with propane instead of natural gas?
- A: Yes, all models are available in Natural Gas or Propane (LP). For Propane models, replace the N with P in the model number.
- Q: What is the warranty coverage for this water heater?
- A: The warranty includes 15 years for the heat exchanger, 5 years for parts, and 1 year for labor.
EASY INSTALLATION
- Industry Leading! 43′ vent run capability
- Enhanced design up to 10% smaller to fit in even more places than before
- Enhanced design up to 22% lighter making one-person installs even easier
READY FOR RETROFITS
- Industry Best! 1/2″ side to side clearance allows you to safely work in spaces the competition can’t
- 1/2″ Gas line compatibility up to 24 ft (subject to local code)
- Universal Venting Compatibility with UBBINK, Metal Fab, and Rainbow venting for easier tankless to tankless replacements
KEY FEATURES
- Richmond® Exclusive! Hot-start Programming™ ensures the unit is in a ready state between back-to-back usage, minimizing any cold water bursts
- Built-in EcoNet® Wi-Fi technology for direct control from your device (on select models)
- LeakGuard® – All-inclusive leak detection and prevention system that detects any leak that comes from the unit (on indoor Wi-Fi models)
SPECIFICATIONS
__
Richmond Model Number
| | INDOOR| | | OUTDOOR|
---|---|---|---|---|---|---
RMTG- 70DVLN-3| | | RMTG- 70XLN-3| RMTG-
84XELN-3
(Wi-Fi Model)
| RMTG- 95XELN-3
(Wi-Fi Model)
Built-in LeakGuard ™ **Model Number| | RMTG- 84DVELN-3**
(Wi-Fi Model)
| RMTG- 95DVELN- 3
(Wi-Fi Model)
|
Gas Input Rate (BTU/h)| MAX| 160,000| 180,000| 199,900| 160,000|
180,000| 199,900
MIN| 11,000| 11,000| 11,000| 11,000| 11,000| 11,000
Uniform Energy Factor (UEF)| 0.82
Hot Water Flow Rate Capacity – Gallons Per Minute
(GPM)| MAX (35°F)| 7.0| 8.4| 9.5| 7.0| 8.4| 9.5
45°F Rise| 6.0| 6.7| 7.4| 6.0| 6.7| 7.4
67°F Rise| 4.1| 4.5| 5.0| 4.1| 4.5| 5.0
Number of Bathrooms 1| 2-3| 3| 3-4| 2-3| 3| 3-4
Temp. Range| 100°F – 140°F
Temp. Setting from Factory| 120°F
High Temp. Upgrade Available| No
Freeze Protection| -30°F Air Intake2, -4°F Ambient
Heat Exchanger Material| Primary: Copper
Minimum Activation Flow| 0.4 GPM
Minimum Continuous Flow| 0.26 GPM
Maximum Altitude| 7,800 ft.
Ultra Low NOx| Meets 14 ng/J NOx requirements – SCAQMD Rule
1146.2 compliant
Warranty| 15 Year Heat Exchanger | 5-Year Parts | 1-Year Labor
Height| 24.2″| 20.75″
Width| 13.5″| 13.5″
Depth| 10.27″| 9.4″
Weight (Lbs.)| 46.5| 42
Venting Diam. Allowed| 3″ by 5″CONCENTRIC| N/A
Max. Single Vent Run (straight pipe)| 43 ft.| N/A
Approved Venting Manufacturer| Metal Fab, Rainbow, UBBINK
Manifold Controls (max. units)| 6 Units3
Controls| Built-in digital display| External Remote (Included)
Power Supply| 120V 60Hz
Max. Power Consumption| 85W (Normal use), 0.7 Amps 132W (Antifreeze),
1.1 Amps 3.5W (Standby), 0.03 Amps4
Gas Connection| 3/4″ NPT
Hot Water Connection| 3/4″ NPT
Cold Water Connection| 3/4″ NPT
All models are available in Natural Gas or Propane (LP). For Propane replace the N with P for LP model
Indoor & Outdoor Models 11,000-199,900 BTU/h Natural Gas and Liquid Propane Models*
*Swap P for N in model number for Liquid Propane model
Clearances
Top / Bottom| 12″
Front| 1/2″5
Sides| 1/2″
Back / From Vent Pipe| 0″
Based on simultaneous showers using 2.0 GPM flow rate pre-mixed with cold water line. Flow rates vary depending on temperature of incoming cold water and water heater set temperature. Refer to 9 zone ground water temperature map for accurate sizing. 2 For indoor application, this is the temperature of outdoor intake air. 3 Manifolds with standard RJ11 communication cables. 4 If anti freeze is on and combustion is on, total W will be 217W (85+132). 5 Recommended 24″ clearance for service.
Zone Map
U.S. Ground Water Temperature Zone Map
Average Flow Rates (GPM) by Application
Low Flow Faucet | 0.5 |
---|---|
Bathroom Faucet | 1 |
Kitchen Faucet | 1.5 |
Shower | 2 |
Dishwasher | 2 |
Washing Machine | 3 |
Flow Rate Capacity Table by Zone (Gallons Per Minute – GPM)
Use the U.S. Ground Water Temperature Map to locate your zone. Then use the Flow Rate Capacity Table to determine model flow rate by zone. Flow rates calculated for tankless set temperature of 120°F with a mixed shower temperature of 105°F. Ground water temperatures vary seasonally.
VENTING
SINGLE UNIT: MAX. EQUIVALENT VENT LENGTHS – STRAIGHT PIPE
Number of 90 Elbows| Max Length 3″ / 5″ straight pipe
0| 43 ft. (13.1 m)
1| 41.5 ft. (12.6 m)
2| 38.5 ft. (12.2 m)
3| 34 ft. (11.7 m)
4| 28 ft. (11.3 m)
5| 20.5 ft. (10.8 m)
6| 11.5 ft. (10.4 m)
EQUIVALENT FT. OF ELBOWS
| 3″/5″
90° Elbow| 1.6 ft.
45° Elbow| 9 in.
Venting Materials Allowed: 3-in./5-in. (7.6-cm/12.7-cm) UL-approved Category III Stainless Steel vent materials or water heater manufacturer-approved vent material (MetalFab, UBBINK, and Rainbow)
MIN. VENT LENGTH STRAIGHT PIPE
Number of 90° Elbows| Min. Length 3″/5″ pipe
1| 1.0 ft (0.3 m)
Dimension
INDOOR DIRECT VENT
Hanging bracket are included with water heater.
PARTS & ACCESSORIES
In keeping with its policy of continuous progress and product improvement, Richmond reserves the right to make changes without notice
References
Read User Manual Online (PDF format)