VRH-RICHMOND-30SS Steam Clean Under Cabinet User Manual

June 15, 2024
RICHMOND

VRH-RICHMOND-30SS Steam Clean Under Cabinet

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-product

Dear Customer,
If you follow the recommendations contained in this Instruction Manual, our appliance will give you constant high performance and will remain efficient for many years to come.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE OBSERVE THE FOLLOWING:

  1. Installation work and electric wiring(including switch location) must be done by the qualified person(s) in accordance with local applicable codes and standards,  including fire-rated construction.

  2. This hood may have sharp edges. Be careful to avoid cuts and abrasions during
    installation and cleaning.

  3. The hood must be placed at a minimum distance of 60cm from the cook panel.

  4. Sufficient air is needed for proper combustion and exhausting of gases through the chimney of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association, the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

  5. Ducted fans must always be vented to the outdoors.

  6. This appliance is designed to be operated by adults. Children were not allowed to tamper with the controls or play with this appliance.

  7. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

  8. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
    WARNING- TO REDUCE THE RISK OF FIRE,USE ONLY THE METAL DUCTWORK . WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:

  9. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner, BE CAREFUL TO PERVENT BURNS.If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

  10. ERVER PICK UP A FLAMING PAN-You may be burned.

  11. DO NOT USE WATER, including wet dishcloths or towels- a violent steam explosive will result.

  12. Use an extinguisher ONLY if:

  13. You know you have a Class ABC extinguisher, and you already know how to operate it;

  14. The fire is small and contained in the area where it started;

  15. The fire department is being called;

  16. You can fight the tire with your back to an exit.

WARNING-TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly in low or medium settings.
  2. Always turn the hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
  3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
  4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING- TO REDUCE THE RISK OF FIRE,ELECTRIC SHOCK, OR INJURY TO PERSON, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  2. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidently. When service disconnecting means can not be locked. Securely fasten a prominent warning device, such as a tag, to the service panel.

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

Before the final installation is made check that all parts are in the box. check the finish of the range hood ( scratches or dents), and check the operation of the range hood. If any issues Do Not install the range hood but bring it back to the store where it was purchased

  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • Please read this instruction manual before installing and using this cooker hood. Properly keep this instruction manual in a safe place for future reference.
  • This cooker hood can be used in the Ducted Mode only (ducting fumes to the outside only)
  • Only a qualified and trained service technician can undertake the work of installation and servicing.
  • Check that the mains voltage corresponds to the one indicated on the rating plate fixed inside the hood.
  • Check that the domestic power supply guarantees adequate earthing.
  • Do not connect the hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.)
  • If the hood is used in conjunction with non-electrical appliances (e.g. gas gas-burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening directly with the open air in order to guarantee the entry of clean air.
  • The minimum distance is 30 to 32 inches from the cooker hood to a gas hob, and is 24 to 30 inches to an electric hob. If the installation instructions for gas hobs specify a  greater distance, this must be taken into account.
    NOTICE: Considering the excessive weight, two or more people are required to install or move this appliance. Failure to do so can cause physical injuries.

CHARACTERISTICS

Dimension

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-fig-1

NSTALLATION&USE

NOTE: on the stainless hoods, carefully remove the plastic protective film from the exterior of the surfaces of the hood prior to final installation.
Caution: To Reduce the Risk of Fire And Electric Shock, Install This range only with integral Blowers by a qualified person or agency.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the local code authorities.
  • When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Ducted fans must always be vented to the outdoors.

DESCRITION/CONNECTION
This appliance must be installed in the ducting version

  1. The hoods feature 1 (6″ top round) openings. Run ductwork between the hood location and the roof cap or wall cap. For best results, use a minimum number of transitions and elbows.
  2. Use the proper diagram below, for the replacement of ductwork and the electrical cutout in the cabinet or wall. Warning: to avoid the risk of fire, use only the metal ductwork.

PACKAGE CONTENTS

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-fig-3

  1. Hood
  2. Round Adapter
  3. (2) LED Light
  4. Rubber Gasket
  5. e Philips Head Sheet Metal Screws
  6. Grease Collector
  7. WaterTray
  8. User Manual
  9. Remote Control

TOOLS NEEDED

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-fig-4

  1. Electric Drill & Extended length head driver bit
  2. Safety Gloves
  3. Pencil
  4. Philips Screwdriver
  5. Keyhole Saw
  6. Level
  7. Safety Goggles
  8. Measuring Tape
  9. Aluminum Foil Tape

INSTALLATION

  1. Remove the oil cup first then push the decorative panel down, Take the decorative panel away from the hood.
    CAUTION: Be careful to hurt the fingers when taking away from the decorative panel. Recommend wearing gloves when doing this process.

  2. Remove the aluminum mesh filter

  3. DUCTED INSTALLATION ON 6″ TOP OPENING ADAPTER INSTALLATION
    Attach a 6″ Damper/Duct connector over the top openings NOTE: The 6″ round duct must be squeezed into an oval shape Damper/Duct connector to connect to the openings on the hood.

  4. Hold the installation plate in position under the cabinet. make sure the damper/duct connector enters ductwork and that the damper opens and closes freely.

  5. Mark the installation hole under the cabinet then insert all 4 mounting screws to the cabinet. Do not secure the screws completely in order to hook the range hood.

  6. Hook the hood under the cabinet and push the range hood inward up to in position. Then completely secure the screws.

  7. ? Connect the house power cable to the range hood wring BLACK to BLACK, WHITE to WHITE, and GREEN or BEAR WIRE to GREEN GROUND SCREW.

Install the decorative panel and oil cup turn on the power at the service panel and test for proper operation.

Operation

REMOTE CONTROL
The hood is operated using 6 6-speed touch control switch on the front panel and a remote control.

  1. 0n/off
  2. LAMP
  3. DOWN
  4. UP
  5. AUTO

TIMER DELAY
Note : The AUTO key on the remote control is not for the stream auto- clean. The rangehood will automatically turn into 2 fan speed after pressing.

AUTO-STEAM CLEAN TOUCH CONTROL

  1. The hood is operated using a 6 6-speed touch control switch on the front panel.

  2. The blower switch turns the blower on to six-speed settings:

  3. ON/OFF

  4. LAMP

  5. DOWN

  6. UP

  7. STREAM AUTO-CLEAN

How to set the fan s12eed
Press the button ) to activate the fan, then press buttons and to set the fan speed, press the button to turn off the fan, and automatically memorize the previous setting at the next time of operation. This range hood can be switched to a six-speed setting
How to set the light intensity level
This range hood has two levels of light intensity, press the button to set it to low light intensity, press button again to set it to high light intensity, and Press it again to turn off the light.

How to set the clock

When the hood is on the standby status, press the button for 3 seconds, and the time indicator in the display keeps flashing, press the buttons and to adjust the clock setting, The machine will automatically confirm if without any operation in 5 seconds.

How to set a timer delay

When the fan is working, press a button for 3 seconds, light the timer delay indicator in the display, and the time indicator keeps flashing, Press the button and set the delay time range from 1 min to 15 mins. The machine will automatically confirm the setting without any operation in 3 seconds.

Stream Auto-clean
This appliance features stream auto-clean functionality,, for better cleaning the parts inside, we recommend using the self-clean function every two months of operation, or more frequently for heavy use. Water cup must be used in the process of auto-clean

  1. According to the Max. and Min. water level marks on the water cup proper cleaning mixture (water + neutral detergent) into the water cup and install it to the hood.
  2. Press and hold the button for 1 a second to start the stream auto-clean, This process lasts 3 minutes. Press button or can stop stream auto-clean in the process

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-fig-19

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded . WARNING- Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

MAINTENTANCE&CLEAN

Caution : Unplug or disconnect the appliance from the power supply before servicing.
GREASE FILTER

  • The grease filters should be cleaned frequently (every two months of operation, or more frequently for heavy use). Use a warm detergent solution.
  • Grease filters are washable.
    Remove the grease filters from the hood. Wash the filters, taking care not to bend them. Allow them to be dry before refitting. When refitting the filters, make sure that the handle is visible from the outside. reinstall the grease filters to the hood.

OOD CLEANING

Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:

  • Hot water with soap or detergent is all that is usually needed.
  • Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
  • For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
  • For stubborn cases use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in the direction of polishing lines or” grain” of the stainless finish. Avoid using too much pressure that may mar the surface.
  • Do not allow deposits to remain for long periods of time.
  • Do not use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
  • Do not allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals that may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.
  • Painted surfaces should be cleaned with warm water and mild detergent only.

SPECIFICATION

VRH-RICHMOND-30S- Steam-Clean-Under-Cabinet-fig-20

Warranty

TO OBTOIB BTBOIOT BBBBT BTOBBOBTB

You must present proof of the original purchase date. Please provide an original dated proof of purchase (sales receipt/invoice) in order to obtain service under warranty.

Lifetime Motor Warranty

The motor, which is covered by a lifetime warranty, should be provided free of charge by your local reseller given it failed due to manufacturing defects. Subject to the conditions and limitations set forth below, your local reseller should, at its option, either repair or replace it with the new or refurbished motor to be functionally equivalent to new. The consumer is responsible for all shipping costs.

One Year Parts Warranty

For one year from the date of the original purchase, your local reseller will provide free-of-charge, non-consumable replacement parts or components that failed due to manufacturing defects. Subject to the conditions and limitations set forth below, your local reseller will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. Repaired parts or replacement products will be provided by your local reseller on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. The consumer is responsible for all shipping costs. Consumable parts not covered by this warranty include but are not limited to: Light bulbs, and metal. aluminum and charcoal filters.

Who is Covered

This warranty is extended to the original purchaser for products purchased for ordinary home use.

This Warranty Will Be Voided When

Product damaged through negligence, improper installation, or accident. abuse, misuse. natural disaster. insufficient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair, modification, or failure to follow installation instructions. When a product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than your local reseller’s authorized agents. This limited warranty also does not apply to any product on which the original identification information has been altered. obliterated or removed. has not been handled or packaged correctly or has been sold as second-hand.
What is Not Covered:
Consumable parts such as light bulbs, and metal and charcoal filters. The natural wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents, or cracks due to abuse, misuse, freight damage, or improper installation. Damage of product caused by accident. fire, floods or acts of God. The manufacturer and/or distributor/reseller is not liable for and is not covered under warranty. any loss of properties or any costs associated with removing, servicing, installing, or determining the source of problems with this product. This warranty is valid in the country of the original purchase
at retail. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the warranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail, and, no warranties, whether express or implied, shall apply to this product thereafter.
To obtain warranty service. you may contact your local reseller from which you purchased this product. Please confirm the terms of your local reseller’s policies prior to contacting. Typically, you must include product identification information, including model number and serial number with a detailed description of the problem you are experiencing. You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period.

Disclaimer
Carefully inspect all items for damages before accepting delivery. Note any damages on the freight bill or express receipt. Request the name and signature of the carrier’s agent and keep a copy to support your claim. Upon acceptance of items, the owner assumes responsibility for their safe arrival. Report damages to the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with the necessary forms for filing a claim. Damages caused during transit are not covered under our warranty. Please contact us to file an insurance claim. Please inspect the contents of package(s) carefully upon receiving it! We must be notified of any damages and/or missing parts within five (5) days of your receipt of the package(s). Claims will not be accepted after five (5) days. NOTE: Items were thoroughly tested and carefully packed in our factory before shipping. Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons, fillers, and shipping cartons. A restocking fee of 15% will be charged for all approved return(s). Exchanges or returns may not be accepted if any packaging is missing. Make sure to inspect the hood for damages and defects before installation. Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchanges. Service visits not covered under warranty will carry a service charge. Before Installation: Return for exchange or refund (please see above for acceptable returns). After Installation: NO exchange or refund.

Carefully inspect all items for damages before accepting delivery. Note any damages on the freight bill or express receipt. Request the name and signature of the carrier’s agent and keep the copy to support your claim. Upon acceptance of items, the owner assumes responsibility for their safe arrival. Report damages to
the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with the necessary forms for filing a claim.
Damages caused during transit are not covered under our warranty. Please contact us to file an insurance claim.
Please inspect the contents of package(s) carefully upon receiving it! We must be notified of any damages and/or missing parts within five (5) days upon your receipt of the package(s). Claims will not be accepted after five (5) days. NOTE: Items were thoroughly tested

Contact Us

If you need any assistance, please contact us at l-905-727-8688 or [email protected]. Please have your order number and model of the range hood ready. This information will help us better respond to your request. If you need replacement parts, we recommend that you only use genuine parts. Our accessories and parts are engineered and designed specifically for this series of range hoods, each is rigorously tested assuring the utmost in durability and reliability, providing a factory match, factory-installed appearance, and functionality tailored to each individual range hood model.