VALLOX D10718 Delico Cooker Hood Instruction Manual

June 17, 2024
VALLOX

VALLOX-logo

VALLOX D10718 Delico Cooker Hood

Product Information

Specifications

  • Product Name: Vallox Delico Cooker Hood with MyVallox Ventilation Unit
  • Model: VMAALNLUOAXLX-LINE PTXP MC, PTXPA MC
  • Compatible with Allaway central vacuum cleaner models X, Z, and C series
  • Integration: Digital input D/I1 or D/I2 for on/off status
    indication of a central vacuum cleaner

Product Usage Instructions

Connecting Allaway Central Vacuum Cleaner

  1. For the X and Z series, connect wire connector contacts AHU1 and AHU2 to the ventilation unit.
  2. For the C series, use the integrated on/off status sensor with the specified sticker and connect to the ventilation unit.
  3. For other Allaway models, use an external AO1 on/off status sensor with connectors A and B.

Setting Up Ventilation Unit

  1. Select Programmable input for Digital Input 1 to adjust fan efficiency for central vacuum cleaner compensation.
  2. Select Custom mode for Digital Input 2 to adjust fan efficiency for cooker hood compensation.
  3. In both modes, increase supply airflow and set suitable supply air temperature.
  4. Lower supply air temperature allows higher flow in sub-zero conditions.

Accessing Settings Menu

  1. Press the Arrow buttons to navigate: Expert settings > I/O and bus settings > Input settings.
  2. Select Digital Input 1 and choose Programmable Input for the on/off setting.
  3. Adjust fan speed using the Plus and Minus buttons.

Note on Usage

Avoid simultaneous use of cooker fan, central vacuum cleaner, and fireplace for safety reasons.

FAQ

Q: Can I use the central vacuum cleaner and cooker hood at the same time?

A: It is not recommended to use the central vacuum cleaner, cooker hood, and fireplace simultaneously for safety purposes. Use them individually as needed.

Usage Instructions

  • MyVallox ventilation units can be used to even out the underpressure that is generated in the apartment by the cooker hood in connection to the removal of cooking smells or by the central vacuum cleaner.
  • Please note that the extract airflow of an efficient cooker hood cannot be fully compensated for with a ventilation unit.
  • Compensation requires contact data e.g. from the damper of the cooker hood or cooker fan, from the pressure switch of the extract duct, or the central vacuum cleaner.
  • Contact data is led to the digital input D/I1 or D/I2 of the ventilation unit.

On/off status of the Allaway central vacuum cleaner

  • Contact data that indicates the on/off status of the central vacuum cleaner is led to the digital input D/I1 or D/I2 of the MyVallox ventilation unit.

The on/off status of the central vacuum cleaner as per unit model:

  • X and Z series: integrated on/off status sensor. Wire connector contacts AHU1 and AHU2.
  • C series : integrated on/off status sensor. The on/off status sensor output is equipped with the following sticker: Optional: to the ventilation unit.
  • Other Allaway models : external OI-1 on/off status sensor. Connectors (A, B).
  • To enable compensation for both the cooker hood and the central vacuum cleaner, the custom mode must be used for one of the functions, because the settings of the programmable input are the same regardless of whether they have been set for the digital input 1 or 2. It is most natural to use the custom mode for the compensation of the cooker hood because their settings can be the same.
  • In such a case, the possible separate fireplace switch is connected next to the contact data of the cooker hood.
  • Select Programmable input as the setting used for the digital input 1. Set the efficiency of the supply and extract fans of the programmable input at the level required by the compensation of the central vacuum cleaner.
  • Select Custom mode as the setting used for the digital input 2.
  • Set the efficiency of the supply and extract fans of the custom mode at the level required by the compensation of the cooker hood and/or the custom mode.
  • In both modes, principally increase the supply airflow and select a suitable supply air temperature.
  • The lower the set supply air temperature, the higher the supply airflow that can be maintained in sub-zero temperatures.
  • For the cooker fan, e.g.
  • supply 90%, extraction 40%
  • For the central vacuum cleaner, e.g.
  • 51 MV supply 90%, extraction 40%
  • 096   MV supply 70%, extraction 40%
  • 99 MV supply 70%, extraction 40%
  • 110 MV supply 60%, extraction 40%
  • 145 MV supply 50%, extraction 40%
  • NOTE Never use the cooker fan, the central vacuum cleaner, and the fireplace simultaneously
  • Open the settings menu
  • Use the Arrow buttons to select: Expert settings
  • Use the Arrow buttons to select I/O and bus settings
  • Use the Arrow buttons to select: Input settingsVALLOX-D10718-Delico-Cooker-Hood-fig-1
  • Use the Arrow buttons to select Digital Input 1
  • Use the Arrow buttons to select Programmable input on/of
  • Use the Plus and Minus buttons to select the fanVALLOX-D10718-Delico-Cooker-Hood-fig-2
  • Vallox Oy Myllykyläntie 9-11 32200 LOIMAA FINLAND www.vallox.com
  • Document D10718
  • Valid from 04.02.2020
  • Updated 28.12.2020

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VALLOX User Manuals

Related Manuals