Senso LETO-8 Rectangular Pendant Leto Installation Guide

June 1, 2024
senso

Senso LETO-8 Rectangular Pendant Leto

Specifications

  • Product Name: LETO 8
  • Weight Capacity: At least 0.88lb (0.4kg)
  • Ceiling Thickness Range: Between 1/4″ & 1″ (6mm & 25mm)
  • Warranty: 5 Years
  • Origin: Canada

Product Usage Instructions

Choose Installation Type:
There are two installation types for LETO 8: Housing Installation and Retrofit & Non Fixed Driver Installation.

  • Housing Installation:
1. Install the appropriate housing between ceiling joists.
2. Connect the driver to the line voltage and ground to the enclosure.
  • Retrofit & Non Fixed Driver Installation:
1. Finish ceiling installation ensuring the hole is cut to the appropriate size and location.
2. Ensure the wire reaches the fixture location.
3. Connect the driver to the line voltage and ground to the enclosure.
4. Push the driver into the ceiling.

Installation Process (CLICK!):

  1. Ensure power is off. Lower quick connect wire from ceiling and connect to the fixture until you hear a click.
  2. Compress the 3 springs inward until they clear the hole in the ceiling.
  3. Rotate the fixture to the desired orientation and push it into the hole until springs release and fixture is flush with the ceiling.
  4. Rotate baffle to fine-tune angle.

FAQ

  • What should I do if my ceiling thickness is thinner than 1/4″ (6mm)?
    In such cases, use an #6-32 screw to set the fixture in place securely.

  • How far should I leave around the fixture on the mounting surface?
    Leave a minimum of 3″ (76mm) around the fixture for proper installation and ventilation.

  • What should I do if I face issues during installation?
    If you encounter any difficulties or have questions during installation, please contact us at 403-216-7043 or email us at info@sensolighting.com for assistance.

Overview

Senso-LETO-8-Rectangular-Pendant-Leto-FIG-2

WARNING
Read and follow these instructions before installing or maintaining this product

  • This product is suitable for DRY INDOOR LOCATIONS ONLY
  • Make sure this product is NOT on the same circuit as inductive loads, (e.g. fluorescent bulbs, discharge bulbs, ventilation fans, etc…)
  • Allow air to flow freely around the fixture
  • Do not switch on line voltage until all wiring is complete
  • Incorrect wiring will result in irreparable damage to LED and power supply
  • This product should only be installed by a licensed electrician

Warranty

  • This product must be installed in accordance with all applicable installation codes and ordinance
  • Limited five (5) years warranty
  • Warranty is void in the eventuality of unauthorized modifications and/or improper use

Choose Installation Type

Housing Installation

  1. Install appropriate housing between ceiling joists. Connect the driver to the line voltage and ground to enclosure.

Senso-LETO-8-Rectangular-Pendant-Leto-FIG-3

  1. Finish ceiling installation. Make sure hole is cut to appropriate size and location.
OR

Retrofit & Non Fixed Driver Installation

  1. Ensure wire reaches fixture location.

  2. Finish ceiling installation. Make sure hole is cut to appropriate size and location. Connect the driver to the line voltage and ground to enclosure.

  3. Push driver into ceiling.

OTHER PROCESS

  1. Ensure power is off. Lower quick connect wire from ceiling and connect to fixture until you hear a click.
  2. Compress the 3 springs inward until they clear the hole in ceiling.
  3. Rotate fixture to desired orientation. Push it into hole until springs release and fixture is flush with ceiling.

Senso-LETO-8-Rectangular-Pendant-Leto-FIG-8

  1. Rotate baffle to fine tune angle.
  2. Press against the reflector to adjust angle.(MAX 30°)

Senso-LETO-8-Rectangular-Pendant-Leto-FIG-9

WARNING
Do not scale this when printing this template.

Senso-LETO-8-Rectangular-Pendant-Leto-FIG-10