Product Information

Specifications

  • Product Name: Desigo Control Point BACnet/IP Web Interface
  • Model: PXG3.W100-2, PXG3.W200-2
  • Description: Interface for web-based, graphical operation of BACnet automation stations using Desigo touch panels and devices with an HTML 5.0 web browser.
  • IT Security: HTTPS and BACnet Secure Connect support

Product Usage Instructions

Installation

The device can be mounted on a standard rail or on the wall. It features a plastic housing, LEDs for communication and state indication, service button, and a 2-port Ethernet switch with LEDs per port. It also includes plug-in terminal blocks with screw terminals for easy connectivity.

Power Supply

The device does not support power supply. Ensure proper power source is available as per installation guidelines.

LED Indicators

The device features LED indicators for different functions including Ethernet activity, device status, and service button activity. Refer to the user manual for detailed LED indicator functions and meanings.

Resetting to Factory State

To reset the device to factory state, follow the instructions provided in the user manual. Usually, a specific sequence of actions involving the service button is required.

FAQ

  • How do I access the web interface?
    • To access the web interface, simply open a standard web browser that supports HTML5 and enter the device’s IP address in the address bar.
  • What are the differences between PXG3.W100-2 and PXG3.W200-2?
    • PXG3.W100-2 offers standard functionality, while PXG3.W200-2 provides extended functionality for a more advanced user experience.

Interface for web-based, graphical operation of BACnet automation stations using Desigo touch panels and devices with an HTML 5.0 web browser.

  • Simultaneous access by various operator units
  • Central administration of graphics and data for other operating views
  • Offline engineering with ABT Site
  • Upload and download configuration data over the IP interface
  • 2-port Ethernet switch for low-cost cabling (10Base-T/100Base-Tx)
  • LED indication for Ethernet link and activity
  • Operating voltage AC 24 V or DC 24 V
  • Plug-in screw terminal block for supply
  • Mounting on DIN rail or on the wall
  • Building X integration
  • BACnet Secure Connect communication as BACnet/SC node

Functions

The device has a web server that processes data from various Desigo automation stations and other devices based on BACnet IP to HTML5 web pages.

The following functions are available to operate and monitor a plant:

  • Log-in and log-out
  • User administration
  • Customized graphics
  • Alarm view to monitor and log alarms
  • Alarm forwarding to e-mail recipient
  • Graphics-based operation of time schedules
  • Graphically displaying trend data
  • Generic operation of all objects and properties of assigned devices
  • Cloud connectivity to Building X for remote access
  • BTL tested BACnet communication, in compliance with BACnet standard including B-OD profile (Rev. 1.16). IT security including HTTPS and BACnet Secure Connect. BACnet Secure Connect support as BACnet/SC node.

Application

SIEMENS-PXG3-W100-2-Desigo-Control-Point-fig
\(1\)

The web interfaces PXG3.W100-2 and PXG3.W200-2 are the central points of access to operate the automation level and room automation. The central point of access permits simultaneous operation on various operator units and supports

  • Connection of Desigo touch panels PXM30-1, PXM40-1 und PXM50-1
  • Access via devices using a standard web browser with HTML5

Type summary

Type Order number Description
PXG3.W100-2 S55842-Z140 BACnet/IP web interface with standard functionality
PXG3.W200-2 S55842-Z141 BACnet/IP web interface with extended functionality

Product documentation

Type of document Document no.
Data sheet BACnet/IP Touch Panels PXM30.E / PXM40.E / PXM50.E A6V11664137
Data sheet Touch Panel Clients PXM30-1 / PXM40-1 / PXM50-1 A6V11664139
Desigo Control Point Basic documentation A6V11666339
Desigo Touch-Panel Clients Commissioning A6V11604303
Desigo Control Point Operating manual A6V11211557
Desigo Control Point Engineering manual A6V11604297

Related documents such as the environmental declarations, declarations of conformity, etc., can be downloaded from the following Internet address: www.siemens.com/bt/download

Technical and mechanical design

The device can be mounted on a standard rail or on the wall.

| 1| Plastic housing
---|---|---
2| LEDs for communication and state
3| Service button
4 a)| 2-port Ethernet switch with 2 LEDs per port
4 b)| Not supported
5| Plug-in terminal blocks with screw terminals Power supply
6| Not supported
7| Not supported
8| Not supported
9| Slider for mounting on standard mounting rails
10| Eyelets for cable ties
11| Holes for wall mounting
12| Date / Series and Serial number

LED indicators and service pin

Activity LED / Interface Color Activity Function
**** Ethernet 1…2 Green Continuously ON Continuously OFF Flashing Link

active

No connection Network traffic

Yellow| Continuously ON Continuously OFF| Link 100 Mbps

Link 10 Mbps

****| RUN| Green| Continuously ON Continuously OFF Flashing| Device operational Device not operational

Start-up or program halted

 | Red| Continuously OFF Continuously ON


Rapid flashing

| OK

HW or SW fault – power off and on the device

Firmware or application missing/corrupted

****| Blue| Steady ON Blinking


Steady OFF

| Cloud connection OK

Cloud connection enabled but no connection available

Cloud connection disabled

SVC| Red| Continuously OFF Flashing| OK

Device is not configured

 |  | Flashing per wink command| Identification of the device after receipt of wink command
 |  |  | ****



 |  | |
COM1 / 2 TX| Yellow| Continuously OFF| Function not supported
COM1 / 2 RX| Yellow|  |
****| Service button|  | Short press| Identification on the network
As per description:| Do the following to reset the device to factory state:

1.     Power off the device.

2.     Power on the device.

3.     Wait until all LEDs light up and turn off again, then press the Service button.

4.     Keep the Service button pressed until all LEDs light up, then release the button.

All LEDs turn off, the device restarts.

5.     Wait until the device has fully started up

– unconfigured (green RUN LED and red SVC LED are flashing).

Safety

CAUTION

National safety regulations

  • Failure to comply with national safety regulations may result in personal injury and property damage.
  • Observe national provisions and comply with the appropriate safety regulations

Mounting position and ambient temperature

The devices can be snapped onto standard rails or screwed onto a flat surface. Plug-in screw terminals connect power and interfaces (except for Ethernet).

Ambient temperature: -5…50 °C (23…122 °F)| Ambient temperature: -5…45 °C (23…113 °F)
---|---
●      Wall, horizontal

–   From left to right

–   From right to left

| ●      Overhead

●      Wall, vertically

From top to bottom

–   From bottom to top

●      On a horizontal surface

CAUTION

Risk of overheating for failure to comply with ambient temperature Burning and damage to the device

  •  Ensure sufficient ventilation to comply with the permissible ambient temperature within the panel or installation box. The temperature must be at least 10 K (18° F) lower outside the installation box.

Installation

WARNING

Electric shock
Incorrect installation of the device may lead to electric shock injuries when touching the device!

  • Install the device in a lockable cabinet or use terminal covers.
  • Do not install the device in locations where children are likely to be present.
  • Conductors with a cross-section of 0.5 mm2 (AWG24) or greater shall comply with the requirements of IEC 60332-1-2 and IEC 60332-1-3 or IEC TS 60695-11-21.

Disposal

The device is considered an electronic device for disposal in accordance with European Directive and may not be disposed of as domestic waste.

  • Use only designated channels for disposing the devices.
  • Comply with all local and currently applicable laws and regulations

Technical data

Power supply

SIEMENS-PXG3-W100-2-Desigo-Control-Point-fig 15

Power consumption (for transformer planning)

Power consumption AC Base load

With USB (not supported)

| ****

10 VA

16 VA

---|---
Power consumption DC|
Base load| 5 W
With USB (not supported)| 8 W

Function data

Hardware information

Processor| NXP i.MX8 DualX, 1 GHz
Storage| 2 GB RAM

8 GB eMMC

Real-time clock

  • Energy reserve (Supercap) to support real-time clock (7 days).

Interfaces

Ethernet interface

Plug| 2 x RJ45, shielded
Interface type| 10Base-T / 100Base-TX, IEEE 802.3 compatible
Bit rate| 10/100 Mbps, autosensing
Protocol| BACnet/IP on UDP/IP, BACnet/SC on TCP/IP, and HTTPS on TCP/IP
Cabling, cable type| 10 Mbps: Min. CAT3, shielded cable is recommended 100 Mbps: Min. CAT5, shielded cable is recommended
Cable length| Max. 100 m (330 ft)
Screw terminals, plug-in

Cu-wire or Cu-strand with wire end sleeve| 1 x 0.6 mm ∅ to 2.5 mm2 (22 to 14 AWG)

or 2 x 0.6 mm ∅ to 1.0 mm2 (22 to 18 AWG)

Cu-strand without wire end sleeve| 1 x 0.6 mm ∅ to 2.5 mm2 (22 to 14 AWG)

or 2 x 0.6 mm ∅ to 1.5 mm2 (22 to 16 AWG)

Stripping length| 6…7.5 mm (0.24. 0.29 in)
Screwdriver| Slot screws, screwdriver size 1 with shaft ø = 3 mm
Max. tightening torque| 0.6 Nm (0.44 lb ft)

Conformity

Ambient conditions and protection classification

Classification as per EN 60730 Automatic action

Control function Degree of pollution

Overvoltage category

| ****

Type 1 Class A 2

I

Protection against electric shock| Protection class III
Degree of protection of housing to EN 60529 Front parts in DIN cut-out

Terminal part

| ****

IP30 IP20

Climatic ambient conditions

●      Storage / Transport (packaged for transport) as per IEC EN 60721-3-1 / IEC EN 60721‑3‑2


●      Operation as per IEC/EN 60721-3-3

| ****

●      Class 1K22 / 2K12

Temperature -25…70 °C (-13…158 °F)

Air humidity 5…95 % (non-condensing)

●      Class 3K23

Operation in enclosed, dry locations, having no temperature or humidity control

Temperature -5…50 °C (23…122 °F) (for details see chapter Mounting)

Air humidity 5…95 % (non-condensing)

Mechanical ambient conditions

●      Transport per IEC/EN 60721-3-2

●      Operation as per IEC/EN 60721-3-3

| ****

●      Class 2M4

●      Class 3M11

Standards, directives and approvals

Product standards| IEC/EN 60730-1 and IEC/EN 62368-1
Product family standard| IEC/EN 63044-x
Electromagnetic compatibility (EMC)| For residential, commercial, and industrial environments
EU conformity (CE)| See CE declaration 1)
EAC compliance| Eurasian compliance
RCM conformity| See RCM declaration 1)
UL/cUL certification (US / Canada)| UL916; http://ul.com/database
CSA certification| C22.2, http://csagroup.org/services- industries/product- listing
FCC| CFR 47 Part 15B
BACnet| Profile: B-OD Revision: 1.16

Detailed information on BACnet certificates, BTL listings, and PICS can be found on the BACnet website (filtered for Siemens products)

Environmental compatibility 1)| The product environmental declaration 1) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Documents can be downloaded at http://siemens.com/bt/download.

European Union conformity Contact for regulatory topics: (EU) Siemens AG, Berliner Ring 23, DE-76437 Rastatt

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation

FCC Caution: Changes or modifications not expressly approved by Siemens Switzerland Ltd. could void user authority to operate the equipment. United States representative

Industry Canada statement

This device complies with ISED’s license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Housing

Color top/bottom 2003 Ti-Grey / 804 Black
Dimensions per DIN 43 880, see dimensions
Weight with/without packaging 350 g / 300 g

Connection terminals

SIEMENS-PXG3-W100-2-Desigo-Control-Point-fig
\(12\) SIEMENS-PXG3-W100-2-Desigo-Control-Point-
fig \(13\)

Dimensions

SIEMENS-PXG3-W100-2-Desigo-Control-Point-fig
\(14\)

Issued by

  • Siemens Switzerland Ltd
  • Smart Infrastructure
  • Global Headquarters
  • Theilerstrasse 1a
  • CH-6300 Zug
  • +41 58 724 2424
  • www.siemens.com/buildingtechnologies
  • © Siemens 2021
  • Technical specifications and availability subject to change without notice.
  • Document ID A6V12304192_en–_f
  • Edition 2024-02-28

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SIEMENS User Manuals

Related Manuals