Specifications

  • Product: Laser Level
  • Model: General Power Tool
  • Category: Laser Levels
  • Power Source: Battery-operated (cordless)
  • Laser Class: Class 2
  • Compliance: IEC 60825-1 Ed. 3

Product Usage Instructions

Safety Guidelines:

Ensure to read and understand all safety warnings, instructions, and specifications provided with the laser level. Failure to follow instructions may result in hazards like electric shock, fire, or injury.

Laser Safety:

Avoid staring directly into the laser beam as it can cause eye damage. Do not point the laser light at others. Exercise caution when using the laser level to prevent accidents.

Work Area Safety:

Only operate the tool if you fully comprehend the operating instructions. Maintain a safe work area to prevent accidents or injuries while using the laser level.

Battery Tool Use and Care:

Follow the specified charging instructions provided in the operator’s manual for safe battery use. Do not make any unauthorized changes or modifications to the equipment to avoid hazards.

Functional Description:

The laser level features a laser aperture, mode button, fuel gauge, power save indicator, on/off dial, pivot bracket, micro adjust, and threaded tripod attachment for accurate leveling and alignment tasks.

Assembly Instructions

Recharge the battery using the designated charger only. Refer to the operator’s manual for specific charging guidelines. Follow the assembly steps outlined in the manual for proper setup of the laser level.

FAQ

Q: Can I use the laser level without reading the manual?

A: It is highly recommended to read and understand the manual before operating the laser level to ensure safe and proper usage.

Q: How do I know if the battery needs charging?

A: Refer to the fuel gauge on the laser level to monitor the battery level. Charge the battery as per the instructions in the manual when needed.

Cat. No. / No de cat.
3624-20
M12™ GREEN CROSS LINE & 4-POINTS LASER
LASER VERT M12™ À 4 POINTS ET LIGNE TRANSVERSALE

WARNING To reduce the risk of injury, user must the risk of injury, user must read and understand read and understand operator’s operator’s manual.

GENERAL POWER TOOL SAFETY WARNINGS

WARNING Read all safety warnings, instruc-tions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

LASER SAFETY

WARNING The beams, device which are produces emitted visible from laserthe tool.

  • This device complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.
  • Laser light – Do not stare into beam or view directly with optical instruments. Do not point laser light at others. Laser light can cause eye damage.

WORK AREA SAFETY

  • Keep work area clean and well lit. Cluttered or dark areas invite accidents.
  • Do not operate power tools in explosive atmo-spheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
  • Keep children and bystanders away while operat-ing a power tool. Distractions can cause you to lose control.

PERSONAL SAFETY

  • Do not allow persons unfamiliar with the tool, these safety instructions, and the tool’s opera-tor’s manual to operate the tool. This tool can be dangerous in the hands of untrained users.
  • Do not overreach. Keep proper footing and balance at all times. This enables better control of the tool in unexpected situations.

BATTERY TOOL USE AND CARE

  • Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack.
  • Use power tools only with specifically designated battery packs. Use of any other battery packs may create a risk of injury and fire.
  • When battery pack is not in use, keep it away from other metal objects, like paper clips, coins, keys, nails, screws or other small metal objects, that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire.
  • Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact ac-cidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
  • Do not use a battery pack or tool that is dam-aged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
  • Do not expose a battery pack or tool to fire or excessive temperature. Exposure to fire or tem-perature above 265°F (130°C) may cause explosion.
  • Follow all charging instructions and do not charge the battery pack or tool outside the temperature range specified in the instructions. Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire.

SPECIFIC SAFETY RULES FOR LASER LEVELS

  • Watch out for erroneous results if the tool is defective or if it has been dropped, misused or modified.

  • Do not dispose of tool or batteries together with household waste material! Tool and batteries that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.

  • Ensure tool magnets are securely mounted to a metal surface. Magnet strength may not hold on thin metal surfaces, causing the tool to fall.

  • Always use common sense and be cautious when using tools. It is not possible to anticipate every situation that could result in a dangerous outcome. Do not use this tool if you do not understand these operating instructions or you feel the work is beyond your capability; contact MILWAUKEE Tool or a trained professional for additional information or training.

  • Maintain labels and nameplates. These carry important information. If unreadable or missing, contact MILWAUKEE for a free replacement.

  • The device conforms to the most stringent requirements of the relevant Electromagnetic Compatibility (EMC) Standards and Regulations. Yet, the possibility of causing interference in other devices cannot be totally excluded.
    CAUTION performance of procedures otherUse of controls or adjustments or than those specified herein may result in hazard-ous radiation exposure.

  • Be sure to power off instrument after use. When instrument will not be used for a long period, place it in storage after removing batteries.

Federal Communications Commission

WARNING Changes or modifications to this unit not expressly ap proved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful in- terference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televi-sion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Consult the dealer or an experienced radio/TV technician for help.

FUNCTIONAL DESCRIPTION

  1. Laser aperture
  2. Mode button
  3. Fuel gauge
  4. Power save indicator
  5. On/Off dial
  6. Pivot Bracket
  7. Micro adjust
  8. Threaded tripod attachment
  9. Magnets
  10. Nail/Screw hole

SPECIFICATIONS

  • Cat. No………………………………………………. 3624-20

  • Volts…………………………………………………….. 12 DC

  • Battery Type…………………………………………..M12™

  • Charger Type…………………………………………M12™

  • Laser……………………………………………………Class 2

  • Lines Max Power……………………………. PAVG ≤ 7 mW

  • Points Max Power………………………….. PAVG ≤ 1 mW

  • Pulse Frequency……………………………………10 KHz

  • Pulse Duration Normal Mode……………… TP ≤ 80 μs

  • Pulse Duration Power Save……………….. TP ≤ 50 μs

  • Wavelength…………………………………… 510-530 nm

  • Lines Beam Divergence……………………………. 1 rad

  • Points Beam Divergence……………………… 0.5 mrad

  • Storage Temp……………………………… -4°F to 120°F

  • Working Range………………………………………….125′

  • Range with Detector……………………………………165′

  • Accuracy………………………………………..±1/8″ @ 33′

  • Settle Time…………………………………… < 3 Seconds

  • Tripod Mount……………………………..1/4″-20, 5/8″-11

  • Ingress Protection…………………………………….. IP54

  • Drop Rating………………………………………………..1 m
    Leveling………….Auto ±°4 side to side, front to back

  • Recommended Ambient

  • Operating Temperature……………….. -4°F to 104°F

SYMBOLOGY

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-2

ASSEMBLY

WARNING Recharge only with the charger specified for the battery. For specific charging instructions, read the operator’s manual supplied with your charger and battery.

Removing/Inserting the Battery
To remove the battery, push in the release buttons and pull the battery pack away from the tool.

WARNING Always remove the battery pack anytime the tool is not in use.

To insert the battery, slide the pack into the body of the tool. Make sure it latches securely into place.

WARNING Only use accessories specifically recommended for this tool. Others may be hazardous.

Power Save
Use power save mode to extend the battery run time. Power save mode is indicated by dimmed laser beams and the Power Save Indicator pulsing. Visual range is decreased in power save mode. Power Save Indicator will change from pulsing to solid Green when turned OFF. The tool will automatically switch to power save mode if less than 7% of battery charge remains.

Fuel Gauge
To determine the amount of charge left in the battery, turn the tool ON. When less than 7% of charge is left, 1 light on the fuel gauge will flash continuously. To signal the end of charge, will flash 4 times and then the tool will shut off. Charge the battery pack. If the battery becomes too hot, the fuel gauge lights will flash. Allow the battery to cool down.

WARNING
To reduce the risk of injury or damage, securely mount/attach the laser before starting an operation. Injury/damage may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser level in multiple ways:

  • Use the embedded magnets to secure the laser level to steel studs, steel beams, etc.
  • Use the keyhole slot to hang the laser level on the wall with a nail or screw.
  • Set the laser level on a flat surface.
  • Position the laser and/or wall mount on a stable surface.
  • Use the 1/4″-20 or 5/8″-11 threaded insert to mount on a tripod.
  • Once the level is mounted, use the micro-adjustment knobs to fine-tune the laser line.

OPERATION

WARNING To reduce the risk of injury or temporary effects on vision, do not look directly into the laser when it is on.

CAUTION Use of controls or adjustments or
performance of procedures other than those specified herein may result in hazardous radiation exposure.

NOTICE Perform the Accuracy Field Check procedure immediately upon unboxing of each new Laser Level and before exposure to jobsite conditions. See “Accuracy Field Check” for information.

Turning On/Off
To turn on the laser and unlock the pendulum, rotate the On/Off dial to the desired position. The remaining battery life will be displayed. WARNING! Do not look directly into laser apertures. Horizontal level line and left/right plumb points will immediately be emitted from aperture in the laser housing.

  • Turns ON the laser and unlocks the pendulum to enable self-leveling.

  • Turns ON the laser but does not unlock the pendulum (self leveling is disabled). The laser lines will flash once every 8 seconds to indicate that the projected lines and dots are not level or plumb.
    NOTICE The ON mode disables self-levelling and therefore is not intended for projecting a level or plumb lines/points.

  • Turns OFF the laser and locks the pendulum.
    When not in use, turn off the tool and store the Laser Level in the protective carrying case
    Use the MODE button to cycle through the three
    laser modes:

  • Horizontal Level Line & Horizontal Points

  • Vertical Plumb Line & Plumb Points

  • Perpendicular Level, Plumb Points and Horizontal Points

Using the Laser Level

  1. For best results, place the tool on a work surface that is:
    • sturdy
    • level (within 4 degrees of true level)
    • free of vibrations
    • 90° to the work area
  2. Turn on the tool.
  3. The tool will self-level when placed on surfaces within 4 degrees of true level when dial is unlocked and on.
  4. The tool is ready once the emitted lines are continuous and no longer moving on the work surface.
  5. If the tool cannot achieve a level state (i.e., the work surface is > 4 degrees off true level), the laser beams will flash rapidly (3 flashes per second). Relocate or adjust the work surface.

Troubleshooting

If the tool does not turn on:

  • Ensure battery is installed properly. Fuel gauge should indicate remaining charge when correctly installed.
  • Ensure battery is charged.
  • Ensure the tool’s internal temperature is within speci-fied operating ranges. If stored in excessive heat or cold, allow at least 2 hours to acclimate to ambient temperature before turning on the tool.
    If problem persists, please contact a MILWAUKEE service facility for support.

ACCURACY FIELD CHECK

NOTICE Perform the Accuracy Field Checkprocedure immediately upon unboxing of each new Laser Level and before exposure to jobsite conditions. See “Accuracy Field Check” for information. Should any deviation from listed product accuracy be found, please contact a MILWAUKEE service facility. Failure to do so could result in rejection of warranty claim.

Influences on Accuracy
Ambient temperature gradients can impact laser accuracy. For accurate and repeatable results, the following procedure should be conducted with the laser elevated off the ground and placed in the center of the working area.
Abusive treatment of the Laser Level, such as exces-sive impacts from drop, can also lead to deviations in product accuracy.
Therefore, it is recommended to conduct the Field Check procedure after any impact or before complet-ing any critical jobs.

Horizontal Height Accuracy
A free measuring distance of approximately 66′ on a firm surface between two walls or structures A and B is required for this check.
It is also suggested to mount the Laser Level to a Tripod for easy adjustment.

  1. Securely mount the tool within 1′ of wall A.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-7

  1. Turn the tool to ON and to Perpendicular Level, Plumb Points, & Horizontal Points mode.
  2. Direct the front laser beam against the nearest wall A and allow to self-level. Mark the center of the laser cross on the wall (point I).
  3. Rotate the tool 180° without changing the height, allow it to self-level, and mark the center of the laser cross on the opposite wall B (point II).

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-9

  1. Move the tool within 1′ of wall B. Allow the laser to self level. Align the laser cross in the general direction of point II on wall B.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-10

  1. Adjust the height of the tool (using the tripod or by adding shims, if required) to align the laser cross directly onto point II on wall B. Allow the tool to self-level.
  2. Rotate the tool 180° without changing the height, allow it to self-level, and mark the center of the laser cross on wall A (point III). Point III should be aligned as vertically above or below point I on wall A as possible.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-11

  1. The distance between points I and III on wall A is the height deviation (d) of the tool. This distance should not exceed 1/8″ (max.) at 33′ (1/2″ at 132′). For the Measuring distance of 2 x 66′ = 132′, the maximum allowable deviation (d) is: 132′ x ±1/8″ ÷ 33′ = ±1/2″.

Horizontal Leveling Accuracy
A free measuring space of approximately 33’x33′ on a firm surface between two walls or structures A and B is required for the check.
It is also suggested to mount the Laser Level to a Tripod for easy adjustment.
Securely mount the tool on one side of the room and centered between walls A and B. Direct the laser lines toward the other side of the room such that the horizontal line appears on both walls A and B. Allow the laser to Self-Level.

  1. Turn the tool to ON and to Horizontal Level Line mode and Horizontal Points mode.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-12

  1. Mark the center of the plumb point on the wall (point I). Also, mark the center of the plumb point on the opposite wall (point II).
  2. Rotate the tool 180°. Align the center point of the laser beam directly onto the wall point II.
  3. Mark the center point of the laser beam on wall A (point III).
  4. The distance d between marked points I and III on wall A indicates the actual deviation (d) of the tool.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-12

  1. For the Measuring distance of 2 x 33′ = 66′, the maximum allowable deviation (d) is: 66′ x ±1/8″ ÷ 33′ = ±1/4″. Thus, the difference d between points I and III should not exceed 1/4″ (max.) at 66′.

Vertical Leveling Accuracy
A door opening with approximately 8′ of space on each side of the opening is required for this check.

  1. Securely mount the tool 8′ from one side of the door opening.
  2. Turn the tool to ON and to Vertical Plumb Line & Plumb Points Mode or Perpendicular Level, Plumb Points, and Horizontal Points mode.
  3. Position the tool with the laser towards the door opening. Allow the tool to self-level.
  4. Mark the center of the vertical laser line on the floor in the middle of the door opening (point I), at a distance of 8′ beyond the door opening (point II), and at the upper edge of the door opening (point III).

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-14

  1. Move the laser level directly behind point II on the other side of the door. Align the vertical laser line so the center is directly aligned with points I and II.
  2. Mark the center of the vertical line at the upper edge of the door opening (point IV).
  3. Measure the height of the door opening.
  4. The distance between points III and IV on the upper door opening is the vertical deviation (d) of the tool.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-15

  1. The maximum vertical deviation (d) is: dmax = 2 x H (door opening) x ±1/8″ ÷ 33′. Example: for a door opening height of 7′, the maximum permitted deviation (d) is: dmax = 2 x 7′ x ±1/8″ ÷ 33′ = ±0.05″ Therefore, the measurement between points III and IV on the upper door opening should not exceed 0.05″ in a 7′ doorway

Plumb Dot Accuracy

A free measuring distance of approximately 16.5′
between floor and ceiling on a firm surface is required
for this check.

  1. Place the tool within 1′ of the floor.
  2. Turn the tool to ON and to Vertical Plumb Line Mode or Perpendicular Level, Plumb Points, and Horizontal Points mode.
  3. Set tool on ground and mark the center of the plumb point on the ceiling (point I). Also, mark the center of the plumb point on the floor (point II).

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-16

  1. Rotate the tool 180°. Align the center point of the laser beam directly onto the floor point II.
  2. Mark the center of the top plumb point on the reference line on the ceiling (point III).

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-17

  1. The distance between points I and III on the ceiling is the deviation (d) of the tool. This distance should not exceed 1/8″ (max.) at 33′. For the Measuring distance of 2 x 16.5′ = 33′, the maximum allowable deviation (d) is: 33′ x ±1/8″ ÷ 33′ = ±1/8″.

Squaring Procedure

  1. Mark a reference (point x) on the floor that is equidistant from each wall in the center of a room.
    Turn ON the laser and switch to the “Unlocked” position. Ensure that laser is in Perpendicular Level, Plumb Points, and Horizontal Points mode (all lasers ON). Using the down plumb point, align the laser directly over the center of point (x) on the floor. With the laser in place, mark point (I) at the intersection of the lines directly in front of the laser on wall A. Without moving the laser, also mark the center of the right Horizontal point (II) on wall B.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-18

  1. Rotate the laser 90 degrees clockwise around plumb point (x) and align the left Horizontal dot with the previously marked point A. With the laser in position, mark point (III) on wall B at the intersection of the perpendicular lines directly in front of the laser. Without moving the laser, mark point (IV) on wall C using the right horizontal point.
    The deviation (d) between points II & III should be no more than 1/8″ at 33′

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-19

  1. Lastly, rotate the laser 180º clockwise around plumb point (x) so that the right horizontal point is aligned with the previously marked point I. Without moving the laser, using the left horizontal point mark (V) on wall C. The deviation (d) between points IV & V should be no more than 1/8″ at 33′.

Milwaukee-3624-20-M12-12-Volt-Lithium Ion-Cordless-Green-Cross-Line-and-4
-Points-Laser-fig-20

MAINTENANCE

WARNING To reduce the risk of injury, always remove the battery before performing any maintenance. Never disassemble the tool.

Maintain Laser Level
Maintain tools. If damaged, have the tool repaired before use. Accidents may be caused by poorly maintained tools.

WARNING To reduce the risk of personal injury and damage, never immerse your tool in liquid or allow a liquid to flow inside them.

Cleaning
Clean dust and debris from any vents. Keep tool clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean, since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia. Never use flammable or combustible solvents around tools.

Cleaning the Lenses
Blow off loose particles with clean compressed air. Carefully wipe the surface with a cotton swab moistened with water.

Repairs
For repairs, return the tool, battery pack and charger to the nearest authorized service center.

ACCESSORIES

WARNING Use only recommended accessories. Others may be hazardous.
For a complete listing of accessories, go online to www.milwaukeetool.com or contact a distributor.

SERVICE – UNITED STATES

1-800-SAWDUST (1.800.729.3878)
Monday-Friday, 7:00 AM – 6:30 PM CST or visit www.milwaukeetool.com
Contact Corporate After Sales Service Technical Support with technical, service/repair, or warranty questions.
Email: metproductsupport@milwaukeetool.com
Become a Heavy Duty Club Member at www.milwaukeetool.com to receive important notifications regarding your tool purchases.

SERVICE – CANADA

Milwaukee Tool (Canada) Ltd
1.800.268.4015
Monday-Friday, 7:00 AM – 4:30 PM CST
or visit www.milwaukeetool.ca

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals