DRI-EAZ Velo Pro Low Profile Air Mover Owner’s Manual

June 5, 2024
DRI-EAZ

Velo Pro Low Profile Air Mover
Owner’s Manual

Phone: +1 800-932-3030 Fax: +1 360-757-7950 LegendBrandsRestoration.com
The Velo and Velo Pro Airmovers use a patented housing design to produce concentrated, broad-path airflow to accelerate the evaporation of moisture from materials for drying.
Patents: http://www.LBpatents.com

READ AND UNDERSTAND THESE INSTRUCTIONS

WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING! The unit must be grounded. Do not use an extension cord. Connect only to an outlet provided with a ground fault interrupting device.
WARNING! Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power cord is damaged, it must be replaced by a cord of the same type and amperage rating.
WARNING! Do not touch grills when the unit is operating.
WARNING! Do not allow children to play with or around the unit. Be sure the unit is inaccessible to children when not attended.
WARNING! Always operate the unit on a stable, level surface so it cannot fall and cause injury.
WARNING! Do not operate any fan with a damaged cord or plug. Discard the fan or return it to an authorized service facility for examination and/or repair.
WARNING! Do not run cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange cord away from traffic area to avoid creating a trip hazard.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving the unit.
NOTICE: Do not alter or modify your Velo in any way. Use only replacement parts authorized by Legend Brands, Inc.
Modifications or the use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.

BEFORE YOU BEGIN
Warranty registration
Please visit warranty.legendbrandsrestoration.com to register your purchase. If you determine service is required, have your equipment model, serial number, and original proof of purchase available and call your distributor for assistance with obtaining a return material authorization (RMA).

Fig. A: Parts Identification

DRI-EAZ Velo Pro Low Profile Air Mover - Parts
Identification

Fig. B: Operating Positions

DRI-EAZ Velo Pro Low Profile Air Mover - Operating
Positions

OPERATING INSTRUCTIONS
Note that the Velo can be placed in a variety of positions for drying and air circulation. See Fig. B for details.

  1. Unwrap the cord and plug the unit into a standard 115V GFCI-protected outlet. CAUTION: Be sure the switch is in the off position before connecting the unit to a power outlet.

  2. Direct the Velo outlet toward the surface to be dried.
    TIP: On the Velo Pro, the airflow may be adjusted by pressing the Up or Down arrow on the speed control (Fig.D). A digital readout shows the approximate amp draw.
    Use this value to maximize the number of Velos you can place on a single circuit.

  3. When the surface is dry to the touch, switch the unit off and reposition the unit in the next area to be dried.

  4. When finished, unplug the unit and re-wrap the cord in the cord wrap.
    For additional instructions about the use of air movers for restorative drying, see Tech Tips under Resources on www.LegendBrandsRestoration.com.

Electrical safety devices
Circuit breaker: If the circuit breaker detects an overload or short circuit conditions, the breaker will automatically shut off the electrical supply. If this occurs, check the power cable carefully for any damage and ensure it is plugged into a properly grounded outlet. Press the Circuit Breaker Reset Switch (Fig. A) to reestablish the electrical supply.
Ground Fault Circuit Interrupter: If the GFCI device detects a ground fault, it will automatically shut off the electrical supply. If this should occur, check the power cable carefully for damage and ensure it is plugged into a properly grounded outlet. Press the GFCI reset button (Fig. A) to reestablish the electrical supply.
TRANSPORT AND STORAGE
Always use the handle to load or carry the unit.
Wrap cord in either direction under the front Cord Wrap tab and rear bottom edge (Fig. A). Pull cord snug and secure with plug clip.
Units may be stacked for transport and storage.
When transporting in a vehicle, secure the unit(s) carefully to prevent sliding and damage to the unit and/or injury to vehicle occupants.
Keep unit dry. Do not expose the unit to rain or snow.
MAINTENANCE
WARNING: Unplug the unit before performing any maintenance.
Before each use
Inspect the power cord. If the cord is damaged, do not use it.
Always grasp the plug (not the cord) to unplug.
As needed
The exterior may be cleaned with a mild solution of detergent. Ensure housing is completely dry before use.
To clean the interior, see Fig. C for instructions.

Fig. C: Disassembly

Fig. D (Pro only)
Variable speed control with amp and total unit hours display

FOR SERVICE CALL YOUR LOCAL DISTRIBUTOR or the Legend Brands Service Department at 800-932-3030.
Be sure to visit warranty.legendbrandsrestoration.com to register your purchase. Your registration will help us provide you with updated product information as needed.
WARNING: This product and other substances that may become airborne from its use contain chemicals, including lead, known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information, go to P65Warnings.ca.gov

SPECIFICATIONS

Model Velo 2-Speed Velo Pro
Weight 19.3 lbs. I 8.8 kg 21.2 lbs. I 9.6 kg

Dimensions
(D x W x H)| 24 x 18 x 9 in.
61 x 45.7 x 22.9 cm| 24 x 18 x 9 in.
61 x 45.7 x 22.9 cm
Amp draw (115V)| 1.7 amps (low)
2.1 amps (high)| 1.2-1.9 amps
Velos per 15 amp circuit| Up to 7| Up to 10
Power| 190.0W (low)
241.5W (high)| 185W
Air movement| 511 CFM (low)
885 CFM (high)| 500-885 CFM 850-1504 CMH
Static pressure| 1. (low)28 in.
1.7 in. (high)| 1.65 in. (HO)
Sound level (avg.)| 59. 9 dB (low)
71.5 dB (high))| 69 dB
Control| Two-speed rocker switch| On/Off switch with variable speed
Cord length| 18 ft. I 5.5 m| 18 ft. I 5.5 m
Fan| 6 blades| 6 blades
Construction| Injection-molded housing; steel wire inlet and outlet grills.| Injection-molded housing; steel wire inlet and outlet grills.
Safety| ETL tested to UL and CSA standards| ETL tested to UL and CSA standards
Specifications are subject to change without notice. Some values may be approximate.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals