BainUltra Bain de Ville Bathtub Instruction Manual
- June 12, 2024
- BainUltra
Table of Contents
- Bain de Ville Bathtub
- SAFETY INSTRUCTIONS
- INSTALLATION INSTRUCTIONS
- INTEGRATED WASTE & OVERFLOW AND CABLE DRIVEN WASTE & OVERFLOW KITS
- BEDDING AND DRAIN POSITION
- LEVELING AND TURBINE LOCATION
- SECURING
- FRAMING INSTRUCTIONS
- TURBINE REMOTE INSTALLATION
- REMOTE TURBINE – ELECTRICAL CONNECTION
- ELECTRICAL DIAGRAMS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Bain de Ville Bathtub
BAIN DE VILLE ™
INSTALLATION INSTRUCTIONS
IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER
TO BE KEPT BY THE OWNER
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY
READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS THIS DOCUMENT
SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.
WARNING
- Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a Hydro-thermo massage ® bathtub equipped with a heater.
- Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage bathtub equipped with heater immediately following strenuous exercise.
- Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater.
- Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage bathtub equipped with a heater.
- Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended by the manufacturer.
- Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature exceeding 100ºF (38ºC) may be harmful to your health.
- To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit unless they are closely supervised at all times.
- To avoid injury, exercise care when entering or exiting the Thermomasseur ® .
- The Geysair should always be connected to the hot water intake. If it is not the case, then, the Geysair should be deactivated via the bath control.
RISK OF ELECTRICAL SHOCK
- Disconnect electric power before servicing.
- Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1,5 m) of the Thermomasseur.
- Before using the Thermomasseur, its installation should be completely finished so that a bather cannot accidentally come in contact with electrical components (turbine and power module).
- For indoor use only.
ELECTRICAL CONNECTIONS:
- Never drop or insert objects into any openings.
- The Thermomasseur must be connected only to a supply circuit that is protected by a 20 amp class A ground fault circuit interrupter (GFCI). Optional therapies such as Chromatherapy and/or 2 nd heated backrest and/or WarmTouchShell ® must be connected to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI). This interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer’s instructions. The GFCI ground must be connected. If defective, do not use the Thermomasseur. Disconnect immediately and call a certified electrician.
- Use 12 AWG (for 20 amp dedicated circuit) and 14 AWG (for 15 amp dedicated circuit) copper conductors that resist temperatures of at least 194 °F (90 °C)
- Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more.
- All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.
- Install in accordance with manufacturer’s installation instructions.
- For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury.
WATER LEAK TEST – IMPORTANT
- Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible for any water damage caused by improper installation (see Warranty section in the Owner’s Manual).
INSTALLATION INSTRUCTIONS
INTEGRATED WASTE & OVERFLOW AND CABLE DRIVEN WASTE & OVERFLOW KITS
**** THE LENGTH OF THE PIPE MAY VARY DEPENDING ON THE BATHTUB MODEL
www.bainultra.com
Some products, specifications, and services mentioned in this manual are
described in pending patent applications or are protected by patents.
INTEGRATED OVERFLOW CONNECTION – PVC PIPE
INTEGRATED OVERFLOW CONNECTION – BRASS PIPE
CABLE DRIVEN WASTE AND OVERFLOW CONNECTION
BEDDING AND DRAIN POSITION
BEDDING
Before installing, ensure that the floor underneath the bath can support 1,500
lbs (680 kg). The bath may sit directly on the floor. However, the bath may
also be installed on a bed of concrete. For this type of installation, it is
recommended that you insulate the concrete between two sheets of plastic, one
on floor and the other underneath bath.
DRAIN POSITION
Model | DIMENSION X | DIMENSION Y |
---|---|---|
Bain de Ville 6030 | 10 – 3/8” | 14 – 1/8” |
Bain de Ville 6632 | 10 – 7/8” | 15 – 1/8” |
LEVELING AND TURBINE LOCATION
SECURING
FRAMING INSTRUCTIONS
TURBINE REMOTE INSTALLATION
SUGGESTED INSTALLATION
SITE PREPARATION
TURBINE REMOTE INSTALLATION
-
A 1 ½ inch ID pipe has to run from the tub, back to the turbine location. This pipe can be PVC Tigerflex (spa hose) or rigid PVC or ABS.
-
Maximum distance is 15 feet from the tub, indoors, in a room temperate setting (not outdoors or in a non-temperature controlled area).
-
The minimum size for the turbine enclosure must be: 16’’ x 16’’ x 16’’.
-
Make sure to leave access for servicing needs.
-
The enclosure should have a minimum 4×2 inch opening so the turbine works properly. Not doing so will starve the turbine of air.
It will eventually fail and void its warranty. -
A 20 Amp GFCI (12AWG) 120V dedicated line is needed for the turbine (Geysair is powered by the turbine). If you have additional options on the bath (one or more) a second dedicated line is needed, 15 Amp GFCI 120V (14AWG).
GEYSAIR ®
-
Geysair is installed on the bathtub at the factory and must not be relocated. It gets its power from your turbine. So per your local electrical code, you may have to use a solid core wire (14AWG) and run it in between the turbine location and the bathtub.
This may require a proper conduit for high voltage wires if installed in a cement slab for example. -
Geysair is connected to the hot water supply that goes to your bathtub faucet. It uses a 3/8 compression thread.
LED (CHROMATHERAPY)
- The power modules (inMix module, Litestreme) have to be installed next to the turbine.
- The wires have to be sent from the tub back to the turbine location.
LED: Low voltage for the Chromatherapy .
REMOTE TURBINE – ELECTRICAL CONNECTION
- SEE P. 19 FOR ELECTRICAL DIAGRAMS
WARNING
- All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.
- Electrical power should be turned on only after all the low voltage wires are connected to turbine.
- If this step has not been done, simply disconnect main breaker that is linked to turbine.
- Turbine must be located in a clean and dry space.
- Geysair component cannot be remote mounted. Must never be unplugged.
THERAPIES – ELECTRICAL CONNECTIONS (TUB)
- SEE P. 19 FOR ELECTRICAL DIAGRAMS.
WARNING
- All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.
ELECTRICAL DIAGRAMS
20A THERMOMASSEUR ® & 15A THERAPIES
MIA ® CONTROL CUTTING TEMPLATE
IMPORTANT
Drawing to scale
MIAPLUS ® CONTROL CUTTING TEMPLATE • REMOTELY INSTALLED
WALL INSTALLED
IMPORTANT
Drawing to scale
www.bainultra.com
Some products, specifications, and services mentioned in this manual are
described in pending patent applications or are protected by patents.
1 800 463.2187
Monday to Thursday from 8 a.m. to 6 p.m. (EST) Friday from 8 a.m. to 5 p.m.
(EST)
Printed in Canada. Copyright © December 2022 Bains Ultra Inc. All rights
reserved. 45200689