BainUltra Bain de Ville Bathtub Instruction Manual

June 12, 2024
BainUltra

Bain de Ville Bathtub

BAIN DE VILLE ™
INSTALLATION INSTRUCTIONS
IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNERBainUltra Bain de
Ville Bathtub

TO BE KEPT BY THE OWNER

SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY
READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL.
WARNING

  • Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a Hydro-thermo massage ® bathtub equipped with a heater.
  • Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage bathtub equipped with heater immediately following strenuous exercise.
  • Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater.
  • Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage bathtub equipped with a heater.
  • Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended by the manufacturer.
  • Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature exceeding 100ºF (38ºC) may be harmful to your health.
  • To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit unless they are closely supervised at all times.
  • To avoid injury, exercise care when entering or exiting the Thermomasseur ® .
  • The Geysair should always be connected to the hot water intake. If it is not the case, then, the Geysair should be deactivated via the bath control.

RISK OF ELECTRICAL SHOCK

  • Disconnect electric power before servicing.
  • Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1,5 m) of the Thermomasseur.
  • Before using the Thermomasseur, its installation should be completely finished so that a bather cannot accidentally come in contact with electrical components (turbine and power module).
  • For indoor use only.

ELECTRICAL CONNECTIONS:

  • Never drop or insert objects into any openings.
  • The Thermomasseur must be connected only to a supply circuit that is protected by a 20 amp class A ground fault circuit interrupter (GFCI). Optional therapies such as Chromatherapy and/or 2 nd heated backrest and/or WarmTouchShell ® must be connected to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI). This interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer’s instructions. The GFCI ground must be connected. If defective, do not use the Thermomasseur. Disconnect immediately and call a certified electrician.
  • Use 12 AWG (for 20 amp dedicated circuit) and 14 AWG (for 15 amp dedicated circuit) copper conductors that resist temperatures of at least 194 °F (90 °C)
  • Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more.
  • All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.
  • Install in accordance with manufacturer’s installation instructions.
  • For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury.

WATER LEAK TEST – IMPORTANT

  • Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible for any water damage caused by improper installation (see Warranty section in the Owner’s Manual).

INSTALLATION INSTRUCTIONS

BainUltra Bain de Ville Bathtub - BAIN

INTEGRATED WASTE & OVERFLOW AND CABLE DRIVEN WASTE & OVERFLOW KITS

BainUltra Bain de Ville Bathtub - CABLE

**** THE LENGTH OF THE PIPE MAY VARY DEPENDING ON THE BATHTUB MODEL
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

INTEGRATED OVERFLOW CONNECTION – PVC PIPEBainUltra Bain de Ville
Bathtub - CONNECTION

INTEGRATED OVERFLOW CONNECTION – BRASS PIPEBainUltra Bain de Ville
Bathtub - INTEGRATED

CABLE DRIVEN WASTE AND OVERFLOW CONNECTIONBainUltra Bain de Ville
Bathtub - WASTE

BEDDING AND DRAIN POSITION

BEDDING
Before installing, ensure that the floor underneath the bath can support 1,500 lbs (680 kg). The bath may sit directly on the floor. However, the bath may also be installed on a bed of concrete. For this type of installation, it is recommended that you insulate the concrete between two sheets of plastic, one on floor and the other underneath bath.
DRAIN POSITIONBainUltra Bain de Ville Bathtub - DRAIN
POSITION

Model DIMENSION X DIMENSION Y
Bain de Ville 6030 10 – 3/8” 14 – 1/8”
Bain de Ville 6632 10 – 7/8” 15 – 1/8”

LEVELING AND TURBINE LOCATION

BainUltra Bain de Ville Bathtub - TURBINE

SECURING

BainUltra Bain de Ville Bathtub - SECURING

FRAMING INSTRUCTIONS

BainUltra Bain de Ville Bathtub - FRAMING

TURBINE REMOTE INSTALLATION

SUGGESTED INSTALLATIONBainUltra Bain de Ville Bathtub -
REMOTE

SITE PREPARATION
TURBINE REMOTE INSTALLATION

  1. A 1 ½ inch ID pipe has to run from the tub, back to the turbine location. This pipe can be PVC Tigerflex (spa hose) or rigid PVC or ABS.

  2. Maximum distance is 15 feet from the tub, indoors, in a room temperate setting (not outdoors or in a non-temperature controlled area).

  3. The minimum size for the turbine enclosure must be: 16’’ x 16’’ x 16’’.

  4.  Make sure to leave access for servicing needs.

  5. The enclosure should have a minimum 4×2 inch opening so the turbine works properly. Not doing so will starve the turbine of air.
    It will eventually fail and void its warranty.

  6. A 20 Amp GFCI (12AWG) 120V dedicated line is needed for the turbine (Geysair is powered by the turbine). If you have additional options on the bath (one or more) a second dedicated line is needed, 15 Amp GFCI 120V (14AWG).

GEYSAIR ®

  1. Geysair is installed on the bathtub at the factory and must not be relocated. It gets its power from your turbine. So per your local electrical code, you may have to use a solid core wire (14AWG) and run it in between the turbine location and the bathtub.
    This may require a proper conduit for high voltage wires if installed in a cement slab for example.

  2. Geysair is connected to the hot water supply that goes to your bathtub faucet. It uses a 3/8 compression thread.

LED (CHROMATHERAPY)

  1. The power modules (inMix module, Litestreme) have to be installed next to the turbine.
  2. The wires have to be sent from the tub back to the turbine location.
    LED: Low voltage for the Chromatherapy .

REMOTE TURBINE – ELECTRICAL CONNECTION

  • SEE P. 19 FOR ELECTRICAL DIAGRAMSBainUltra Bain de Ville Bathtub - ELECTRICAL

WARNING

  • All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.
  • Electrical power should be turned on only after all the low voltage wires are connected to turbine.
  • If this step has not been done, simply disconnect main breaker that is linked to turbine.
  • Turbine must be located in a clean and dry space.
  • Geysair component cannot be remote mounted. Must never be unplugged.

THERAPIES – ELECTRICAL CONNECTIONS (TUB)

  • SEE P. 19 FOR ELECTRICAL DIAGRAMS.BainUltra Bain de Ville Bathtub - CONNECTIONS

WARNING

  • All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations.

ELECTRICAL DIAGRAMS

20A THERMOMASSEUR ® & 15A THERAPIESBainUltra Bain de Ville Bathtub -
ELECTRICAL DIAGRAMS

MIA ® CONTROL CUTTING TEMPLATE

IMPORTANT
Drawing to scale 
BainUltra Bain de Ville Bathtub - Drawing to
scale

MIAPLUS ® CONTROL CUTTING TEMPLATE • REMOTELY INSTALLED

WALL INSTALLED
IMPORTANT
Drawing to scaleBainUltra Bain de Ville Bathtub -
CONTROL

www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

1 800 463.2187
Monday to Thursday from 8 a.m. to 6 p.m. (EST) Friday from 8 a.m. to 5 p.m. (EST)
Printed in Canada. Copyright © December 2022 Bains Ultra Inc. All rights reserved. 45200689

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BainUltra User Manuals

Related Manuals