Parameters

General


Net weight| 22kg
Dimension| 432x270x300mm
Battery capacity| 1229Wh; 51,2V    ; 24Ah
Wi-Fi| supported
|

Output

AC socket x3 (Inverter mode)| pure sine-wave; total 1800W (peak 3000W); 220-240V; 50Hz/60Hz; 12A
AC socket (Bypass mode)| 220-240V; 50Hz/60Hz; 1800W max.; 10A max.
USB-A1/A2| 5V   3A; 9V   2A; 12V    1,5A, 18W max.
USB-A3/A4| 5V       2,4A; 12W max.
USB-C1/C2| 5/9/12/15V   3A; 20V  5A; 100W max.
Car charger| 12,6V   10A, 126W max.
DC5521 output x2| 12,6V   3A
|

Input

AC input power| 1800W max.; 10A
AC input voltage| 220-240V; 50Hz/60Hz
PV charge| 400W max.; 13-45V   12A
Car charging input| 12V/24V battery supported, 8A by default
|

Input charging

AC charging power| 1200W max.
PV / car charging power| 400W max.
AC+PV charging power| 1200W max.
|

Battery

Cell type| Lithium iron phosphate (LiFePO4)
Life cycle| 3000 cycles
Protection| Over temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection

Operating temperature


Optimal operating temperature| 20℃~30℃
Discharge temperature range| -20℃~45℃
Charge temperature range| 0℃~45℃
Storage ambient temperature| -20℃~45℃ (20℃~30℃ preferred)

Note : Whether the product can be charged or discharged is subject to the actual battery pack temperature.

Safety instructions

  1. Before using the power station, please read this user manual to ensure understanding and proper use.
  2. Do not place a working power station close to any heat source, such as fire or a heater.
  3. Avoid allowing the power station to come into contact with any liquid.
  4. Do not use the power station in a strong electrostatic or strong magnetic field environment.
  5. Do not disassemble the power station in any way or pierce it with a sharp object.
  6. Avoid short-circuiting the power station with wires or other metal objects.
  7. It is forbidden to step on, sit, or climb on this product.
  8. Do not use non-genuine parts or accessories. For part or accessory replacement, please visit the official sales channel for purchase information.
  9. When using the power station, strictly follow the operating temperature defined in this user manual. If the temperature is too high, the battery may catch fire or even explode. If the temperature is too low, the power station’s performance will be seriously impaired, and normal use may be impacted.
  10. Do not stack heavy objects on the power station.
  11. Do not forcibly stop the fan or expose the power station to an unventilated or dusty environment when it is working.
  12. Please avoid collisions, dropping, and violent vibrations. If a severe impact occurs, shut down the power supply immediately. Secure the power station firmly during transportation to prevent vibration and impact.
  13. If the power station falls into water accidentally, place it in a safe and wide area, and keep yourself away from it until it’s dry. The dried product is not to be used again. Dispose of it properly according to the discard instructions in this manual. If the power station is on fire, please use fire extinguishing equipment in the recommended order: water or water mist, sand, fire blanket, dry powder, carbon dioxide fire extinguisher.
  14. If there is dirt on the power station, use a dry cloth to wipe it.
  15. Place the power station carefully to prevent damage. If the power station is tipped over and seriously damaged, turn off the power station immediately, place the battery in a spacious area, keep it away from flammable materials and people, and discard it in accordance with the requirements of local laws and regulations.
  16. Keep the power station out of the reach of children and pets.
  17. Keep the power station in a dry and ventilated place.
  18. In a humid environment (seaside, water, etc.), it is recommended to equip the power station with a moisture-proof bag. If water is found inside the product, do not use/start it again. Take countermeasures to prevent electric shock before touching the power station. Put it in a safe and waterproof open area and contact customer service immediately.
  19. It is not recommended to use the power station to supply power for safety-related emergency medical equipment, including but not limited to medical-grade breathing machines (hospital version CPAP: Continuous Positive Airway Pressure), artificial lungs (ECMO, Extracorporeal Membrane Oxygenation). It can be used to supply power for the home version CPAP at home and does not require continuous professional monitoring. Follow your doctor’s advice and consult the manufacturer for any restrictions on the use of the device. For general medical equipment, pay attention to the power condition to ensure that power does not run out.
  20. Conditions permitting, be sure to discharge the battery completely, and then put the power station in the specified battery recycling bin.
  21. The power station contains batteries, which are dangerous. It is strictly prohibited to discard them in ordinary dustbins. For details, follow local laws and regulations on battery recycling and disposal.
  22. If the battery cannot be discharged completely due to a product failure, do not discard the battery directly in the battery recycling bin. Contact a professional battery recycling company for further disposal.
  23. The battery will not start after over-discharge. Please dispose of it.
  24. Power supplies will inevitably generate electromagnetic fields when in use, which might affect implantable medical devices or the normal operation of personal medical devices, such as pacemaker devices, cochlear implants, hearing aids, defibrillators, etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that the power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing aids, defibrillators, etc.
  25. When the power station is connected to a refrigerator, it may automatically shut down because of the power fluctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines, or other valuable items, it is recommended to set the AC output to “Never off” in the APP, so as to ensure continuous power. Users should pay attention to power consumption.
  26. During the push-pull movement of this product, it is forbidden to put other items on this product.

Warning

  1. Do not overcharge the internal battery. See instruction manual.
  2. Do not smoke, strike a match, or cause a spark in the vicinity of the power station.
  3. Only charge the internal battery in a well-ventilated area.
  4. CAUTION : Risk of electric shock. Connect only to properly grounded outlets.
  5. CAUTION: Risk of injury to persons. Do not use this product if the power cord or the battery cables are damaged in any way.
  6. CAUTION: Risk of electric shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.
  7. CAUTION: This device is not intended for use in a commercial repair facility.

Product overview

  1. LCD screen
  2. LCD button
  3. USB-C output port x2
  4. AC output button
  5. AC output socket x3
  6. Ventilation opening
  7. On/off button
  8. USB-A quick charge output x2
  9. USB-A output port x2

Product overview

  1. AC input socket
  2. Quick charge/ slow charge switch
  3. Ventilation opening
  4. Overload protection switch
  5. Solar / car charge input

Product overview

  1. LED light
  2. LED light button
  3. Char charge output
  4. DC5521 plug x2
  5. DC output on/off

Product overview

  1. Remaining battery percentage
  2. Remaining charge/ discharge time
  3. Over temperature warning
  4. Low temperature warning
  5. DC output
  6. USB-A output
  7. USB-C output
  8. AC output
  9. Wi-Fi connection status
  10. PV charge
  11. Quick charge
  12. Slow charge
  13. Car charge
  14. Fan status
  15. Overload
  16. Input power
  17. Bluetooth
  18. Output power
  19. Error code Product overview

Battery capacity : when the power station is being charged, the remaining battery percentage (1.) will flicker.

Wi-Fi connection status: The flickering icon indicates that the power station is ready for pairing. The icon will keep flickering if a mobile phone and power station are connected by hotspot. After a successful network connection, the icon will always be on. If the connection fails, the icon will be off.

Use

  1. Press the main power switch to turn on the device; the screen and the power indicator will light up.

  2. If no operation is performed on the power station for 5 minutes, the power station will enter a hibernation state, and the LCD screen will automatically turn off. When there is a load change or operation on the power station, the LCD screen will automatically light up. Press the main power switch to turn on or turn off the LCD screen.

  3. Press and hold the main power switch to turn off the power station.

  4. In normal mode (when the power is above 5%), the default standby time of this product is 2 hours. When the AC output switch is not turned on, and there is no charge or discharge for 2 hours, the product will automatically shut down. The standby time can be set on the APP. When the power is 5% or below, the product will be forced to enter low power mode. In the case of no charge or discharge, the product will adjust the standby time according to the power and automatically shut down.

  5. In normal mode, long-press the LED light button to exit the automatic shutdown setting, and the battery icon on the screen will flash. Long-press again to enter the automatic shutdown setting, and the battery icon will not flash. (The automatic shutdown setting is to protect the battery from low power; exiting this setting may damage the battery life, so please use it with caution.)

  6. Note: When there is no AC input, long press the AC output button. You can switch the AC off-grid output frequency (50 Hz/60 Hz ), long press 2seconds to switch. The AC output icon will flash 3 times after successful switching.

  7. Short-press AC output power switch

  8. USB output is enabled by default after the main power swich is turned on.
    Product overview

  9. After ensuring that the main power is turned on, short-press the AC output power switch to turn on the AC output. Short-press the AC output power switch again to turn it off.

  10. The default standby time of the AC output port is 1 hour. After 1 hour without any load on the AC output port of this product, the AC output power will be automatically turned off. In normal mode, long-press the LED light button; the AC output power switch can exit the automatic shutdown setting, and the battery icon on the screen will flash. Long-press again, and the AC output power switch enters the automatic shutdown setting, and the battery icon will not flash.

  11. Long-press the LED light button to exit the AC automatic shutdown setting: it is applicable to AC equipment below 10W and pulse working equipment.

  12. When the AC output is not in use, turn it off to save power consumption.
    Use
    LED lights
    Short-press the LED light button to switch between four modes: low light, medium light, bright light, SOS and light off.
    12V DC output
    Short press the 12 DC output power switch

  13. After the main power switch is turned on, press the 12V DC output power switch to enable the DC output port.

  14. Press the 12V DC output power switch again to turn it off.

  15. When the 12V DC output power switch is turned on, the power station does not shut down automatically.

  16. Note : Long-press the ON/OFF button to restart the BMS and clear the fault information.

AC charging

Quick charging technology is designed for AC charging. You can control the charging power via the AC charging speed switch. The slow charge mode is on by default when the power station is turned on and can be switched to quick charge mode by pressing the button. Quick and slow charging mode switching can also be set via the app. If the current is continuously higher than 20A, the charging input port will activate the self-protection function, and the charging overload protection switch will automatically trip. Press the charge overload protection switch to restore charging after confirming no faults.

AC wire
Quick charge and slow charge can be switched using the button.

AC-wire

Quick charge enabled
The charging power range can be adjusted via the app.

Quick Charge Enabled

PV charging

  1. Please follow the user manual to connect the solar panels.
  2. Before connecting the solar panel, check whether its output voltage is within the power station specifications to avoid damage to the power station.
  3. The interface of this product is DC7909. If you need an adapter cable from MC4 to DC7909, please purchase it yourself.

Car charging

The power station can be charged using a car charging port. It should be charged after the car starts to avoid car battery loss and failure to start. At the same time, ensure a good connection between the car charging port and the cigarette lighter. We take no responsibility for any loss caused by improper operation.

Intelligent inversion

To avoid operation faults arising from charging overload, when the total output power exceeds the rated output power, the constant output power will be automatically enabled, allowing the power station to supply power to high- power devices at the rated output power.

Please take note of the following while using constant power:

  1. The constant power output function is not enabled by default and can be turned on or off via the app.
  2. The constant power output function is not enabled in the following cases:
    • When AC output is turned on during charging (bypass mode).
    • When constant power output is turned off.
  3. The constant power output function is more suitable for heaters and motors instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). The application of the constant power output function is subject to actual testing.

APP

You can control and view information and data about this product through the app. For detailed usage instructions, please refer to the WiFi Connection Instructions:

QR-code

EPS Function

This product supports the EPS (emergency backup power) function. Connect the power grid to the AC input port of this product using the AC charging cable; it operates in Bypass mode (AC power comes from the grid, not the battery). In the event of a sudden power loss from the grid, the product can automatically switch to battery power supply mode within 14 milliseconds. At this time, it functions in inverter mode. Please note that this function does not support 0 milliseconds switching. Avoid connecting it to devices that require high uninterrupted power supply, such as data servers and workstations, unless compatibility is confirmed through multiple tests. It is recommended to use only one device at a time to avoid overload protection. If the device does not operate normally or data is lost due to failure to follow instructions, we will not be responsible.

EPS Function

Maintenance

  1. It is recommended to use or store the power station in an ambient temperature of 20~30℃. Keep it away from water, heaters, and metal parts, and store it in a dry and ventilated place.
  2. For long-term storage, charge and discharge every 3 months, i.e., discharge to 0% then charge to 100%.
  3. For safety, do not store the power station with a temperature above 45℃ or below -10℃.
  4. If the capacity is lower than 1%, please charge it to 60%. Long-term storage with a serious power shortage will cause irreversible damage to the cell and shorten the service life of the product.
  5. If the capacity is seriously insufficient and idle time is too long, the product will enter deep sleep mode, and it can only be used after being charged.
  6. After charging or discharging this product, wait for more than 30 minutes before using it.

Error codes

Error no. Fault description Solution
1 Serious battery fault Turn on and off. Contact customer service if not

fixed.
2| Pressure difference is too large| Auto shutdown. Fault will be cleared after reboot.
3| BMS voltage fault
4| Battery OTP (over temperature protection) fault| Auto shutdown. Temperature recovery enables starting up.
5| Battery UTP (under temperature protection) fault
6| OCP (over current protection) fault| Auto shutdown. Remove the over-power device. Fault will be cleared after reboot.
7| OTP fault| Auto shutdown. Delayed start.
8| Pre-charge fault| Auto shutdown. Fault will be cleared after reboot.
9| Battery under voltage fault| Auto shutdown and charge. Contact customer service if still not fixed after multiple charging failures.
10| Abnormal parellelization| Check the connection cable. Contact customer service if still not fixed.
Single power station function is not affected.
11| Abnormal INV battery voltage| Auto recover after fault is cleared.
12| Grid voltage or frequency fault| The fault is cleared when the grid returns to normal.
13| Abnormal INV BUS voltage| Auto recover after fault is cleared.
14| Abnormal INV output
15| INV discharge overload| Remove over-power device. Auto recover after fault is cleared.
16| Charge overload| Auto recover after fault is cleared.
17| INV Tz
18| Battery short| Fault will be cleared after reboot.
19| INV output short
20| MOSFET OTP fault| Auto recover after product has cooled down.
21| Fan stop| Turn on and off. Contact customer service if not fixed.
22| Discharge soft start fault| Auto recover after fault is cleared.
23| Charge soft start fault
24| MOSFET UTP fault| Turn on and off. Contact customer service if not fixed.
25| Anderson hardware OCP fault| Remove PV charge. Auto recover after connection PV and turning on.
26| Anderson software OCP fault| Turn off output. Manual recover after fault is cleared.
27| PV hardware OCP fault| Remove PV charge. Auto recover after connection PV and turning on.
28| PV1 software OCP fault| Stop PV1 charging. Auto recover after connecting PV and turn on.
29| PV2 software OCP fault| Stop PV2 charging. Auto recover after connecting PV and turn on.
30| Car charge output OCP fault| Turn off output. Manual recover after fault is cleared.
31| PV output OVP (over voltage protection) fault| Stop PV. Auto recover after fault is cleared.
32| PV1 input OVP fault| Stop PV1. Auto recover after fault is cleared.
33| PV2 input OVP fault| Stop PV2. Auto recover after fault is cleared.
34| Anderson OTP fault| Turn off output. Manual recover after fault is cleared.
35| PV1 OTP fault| Stop PV1. Auto recover after fault is cleared.
36| PV2 OTP fault| Stop PV2. Auto recover after fault is cleared.
37| Car charge output OTP fault| Turn off output. Manual recover after fault is cleared.
38| Abnormal communication| Turn on and off, or change operation environment. Contact customer service if still not fixed.
39| Abnormal USB| Auto recover after removing abnormal USB.
40| Abnormal type C| Auto recover after removing abnormal type C.

Disclaimer

  1. The product has a built-in battery management system with protections such as overcharge, over-discharge, overcurrent, short circuit, high and low temperature, and abnormal communication. During the use of this product, protection may occur, causing output interruption. The power supply to special equipment, such as medical equipment or servers, and any indirect loss caused by accidental power failure, we do not take responsibility for. All accidents caused by illegal use, self-dismantling, and man-made damage we do not take responsibility for.

  2. Before using the power station, please read this user manual to ensure understanding and proper use.
    Keep the user manual for future reference. Improper operation may cause serious injury or result in product damage and property loss. By using the power station, you are deemed to have understood and accepted all terms and contents herein. Users promise to be responsible for their actions and all consequences arising therefrom. The company shall not be liable for any loss arising from the user not following this user manual.

  3. In compliance with laws and regulations, the manufacturer reserves the right of the final interpretation of this document and all related documents of this product. Subject to update, revision, or termination without prior notice, please visit the official website for the latest product information.

Recycling

This product bears the selective sorting symbol for waste electrical and electronic equipment This means that this product must be handled pursuant to European Directive (2012/19/EU) in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities. Electronic products not included in the selective sorting process are potentially dangerous for the environment and human heath due to the presence of hazardous substances.

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

mestic User Manuals

Related Manuals