RS PRO MICA Band Heater 345W 230V Instruction Manual

June 1, 2024
RS PRO

INSTALLATION AND MAINTENANCE INSTRUCTIONS OF MICA BAND HEATER

INSTALLATION

1.1 Before installation, check the surface should be clean and clear of debris.
1.2 Remove any material or dirt and check surface for irregularities which could cause hot spots.
1.3 Check the Resistance Value before installation to check the healthiness of heater.
1.4 After installation, check the proper tightening of heater on barrel and ensure that there should not any gap present in between Heater & Barrel.
1.5 Ensure that medium should be present before energizing the heater.
1.6 Heater must be wired by qualified personnel to electrical code requirements.
1.7 Check supply voltage with heater marking & user specifications before energizing.
1.8 Make sure that the heater is not exposed to water or other liquids. This can damage the heater or result in electrical shock.
1.9 Do not turn the bolt with extra effort as this may damage the connection point.

START-UP INSPECTION

2.1Check that all terminal connections are tightened properly.
2.2 Ensure no physical damages to the temperature sensors or any other part of the heater unit.
2.3 To ensure the safety of the heater, monitor the temperature so that it does not exceed the prescribed value.

MAINTENANCE

3.1 Disconnect power before performing any maintenance servicing.
3.2 Maintenance and repair should be performed only by qualified personnel.
3.3 Periodically check electrical connections for tightness.

Read User Manual Online (PDF format)