RS PRO AC-DC 90W power supply PCB Mount Switch Mode Power Supplies User Guide
- June 1, 2024
- RS PRO
Table of Contents
2761489, 2761491,
2761493, 2761495
Internal
Switching Power Supplies
RS PRO 90W
PCB Mount Switch Mode Power Supplies
Features
- Universal 80 – 305VAC and 110 – 430VDC
- Efficiency up to 93%
- High I/O isolation test voltage up to 4200VAC
- Operating temperature range – 40℃ to +85℃
- 4000m altitude operation
- No-load power consumption < 0.21W
- Compact size, high power density. (87.00 x 52.00 x 29.50 mm)
- Over-voltage category OVC 111 (meet EN61558, 2000m)
- EMI performance meets. CISPR32 / EN55032 CLASS B EN55014
- IEC/EN/UL62368-1, EN61558-1 safety approval
RS Professionally Approved Products bring to you professional quality parts
across all product categories.
Our product range has been tested by engineers and provides a comparable
quality to the leading brands without paying a premium price.
Product Description
Buy this product from https://uk.rs-online.com/
AC-DC PCB mount power supply suitable for a wide range of industrial, consumer
and telecom instruments and applications.
This compact, high efficiency series provides reinforced insulation and
excellent EMC performance.
The converters meet UL/IEC/EN/BS EN62368, IEC/EN60335, EN61558 standards and
perform within the CLASS B limits of CISPR32 / EN55032 without external
components.
Model | AC-DC 90W power supply |
---|---|
Mounting Type | PCB mount |
Package Type | Black plastic, flame-retardant and heat-resistant |
(UL94V-0)
MTBF| MIL-HDBK-217F@25°C > 500,000 h
Applications| Industrial control systems, instrumentation, and
electrical equipment
RS Item No.| Input Voltage| Output Voltage| Output
Current| Wattage| Efficiency (Typ)
---|---|---|---|---|---
2761489| 85 to 305V ac 100 to 430V dc| 12V DC| 6.7A| 80.4W| 92%
2761491| 85 to 305V ac 100 to 430V dc| 15V DC| 5.67A| 85.05W| 92.5%
2761493| 85 to 305V ac 100 to 430V dc| 24V DC| 3.75A| 90W| 93%
2761495| 85 to 305V ac 100 to 430V dc| 48V DC| 1.875A| 90W| 93%
Input Specifications
Input Specification
Voltage Range| 80 to 305V ac, 110 to 430V dc
Frequency| 47 to 63Hz
AC Current Rating| 2A/115V ac, 1.1A/230V ac
Inrush Current| 35A / 115 ac, 65A / 230V ac
Input Protection| 3.15A/300V, slow-blow, required
Item| Operating Conditions| Min| Typ| Max.| Unit
---|---|---|---|---|---
Output Voltage Accuracy| | –| ±2| –| %
Line Regulation| Full Load| –| ±0.5| –
Load Regulation| 0% – 100% load| –| ±1| –
Ripple & Noise*| 20MHz bandwidth (peak-to-peak value)| 12V/15V| –| –| 120| mV
24V| –| –| 200
48V| –| –| 240
Standby Power Consumption| 230VAC| –| –| 0.21| W
Minimum Load| | 0| –| –| %
Hold-up Time| 115VAC| –| 10| –| ms
230VAC| –| 30| –
Temperature Coefficient| | –| –| 0.21| %/°C
Short Circuit Protection| | Hiccup, continuous, self-recover
Over-current Protection| | ≥110% Io, self-recovery
Over-voltage Protection| 12V| ≤16VDC (Hiccup or clamp)
15V| ≤25VDC (Hiccup or clamp)
24V| ≤35VDC (Hiccup or clamp)
48V| ≤60VDC (Hiccup or clamp)
Note: *The “Tip and barrel method”is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 1uF ceramic capacitor, please refer to AC-DC Converter Application Notes for specific information.
General Specifications
Item | Operating Conditions | Min | Typ | Max. | Unit |
---|---|---|---|---|---|
Isolation | Input-output | Electric Strength Test for 1min, leakage current | |||
<5mA | 4200 | – | – | VAC | |
Insulation Resistance | Input – output | At 500VDC | 100 | – | – |
Operating Temperature | -40 | – | +85 | ℃ | |
Storage Temperature | -40 | – | +85 | ||
Storage Humidity | – | – | 95 | %RH | |
Soldering Temperature | Wave-soldering | 260 ± 5℃; time: 5 – 10s | |||
Manual-welding | 360 ± 10℃; time: 3 – 5s | ||||
Switching Frequency | – | 75 | – | KHz | |
Power Derating | -40℃ to -30℃ | 5.0 | – | – |
%/ ℃
+50℃ to +70℃| 2.50| –| –
+70℃ to +85℃| 1.66| –| –
85VAC – 100VAC| 1.0| –| –| %/VAC
Operating Altitude Derating| 2000m-4000m| 10.0| –| –| %/Km
Safety Standard| IEC/UL62368-1, EN60335-1, EN61558-1 safety approved & EN/BS
EN62368-1(Report)
---|---
Safety Class| CLASS II
Vibration| 10 – 500Hz, 2G 10min./1cycle, period for 60min.
Each along X, Y, Z axes
MTBF| MIL-HDBK-217F@25℃| 500,000 h
Product Characteristic Curves
Emissions | CE | CISPR32/EN55032 CLASS B |
---|---|---|
RE | CISPR32/EN55032 CLASS B | |
Harmonic current | IEC/EN61000-3-2 CLASS A | |
Immunity | ESD | IEC/EN 61000-4-2 Contact ± 6KV/Air ±8KV |
RS | IEC/EN 61000-4-3 10V/m | Perf. Criteria A |
EFT | IEC/EN 61000-4-4 ±2KV | Perf. Criteria A |
Surge | IEC/EN61000-4-5 line to line ±2KV | Perf. Criteria A |
IEC/EN61000-4-5 line to line ±2KV (See Fig.2 for recommended circuit) | Perf. |
Criteria B
CS| IEC/EN61000-4-6 10 Vr.m.s| Perf. Criteria A
PFM| IEC/EN61000-4-8 30A/m| perf. Criteria A
Voltage dips, short interruptions and voltage variations immunity|
IEC/EN61000-4-11 0%, 70%| Perf. Criteria B
RS Item No. | C1(µF) | C2(µF) | TVS |
---|---|---|---|
2761489 |
1uF/100V
| 330uF/35V| SMBJ20A
2761491| 330uF/35V| SMBJ20A
2761493| 200µF /35V| SMBJ30A
2761495| 100µF /63V| SMBJ60A
Recommended circuit for IEC/EN61000-4-4 ±4KV and IEC/EN61000-4-5 line to line ±2KV/line to PE ±4KV. Can also be used for Class I equipment should this be required.![RS PRO AC-DC 90W power supply PCB Mount Switch Mode Power Supplies
- fig 1](https://manuals.plus/wp-content/uploads/2024/04/RS-PRO-AC-DC-90W- power-supply-PCB-Mount-Switch-Mode-Power-Supplies-fig-1.png)
Fig. 2: EMC application circuit with higher requirements
Component | Recommended value |
---|---|
FUSE | 6.3A/300V, slow-blow, required |
MOV1 | S14K350 |
CY1/CY2 | 1nF/400VAC |
CX | 684K/310V |
LCM | 10mH, P/N: FL2D-Z5-103 is recommended |
Mechanical Specifications
Case Material | Black plastic, flame-retardant and heat-resistant (UL94V-0) |
---|---|
Dimensions | 87.00 x 52.00 x 29.50 mm |
Weight | 200g (Typ.) |
Cooling Method | Free air convection |
Dimensions and recommended layout
Approvals
Safety Standard| IEC/UL62368-1, EN60335-1, EN61558-1 safety approved & EN/BS
EN62368- 1(Report)
---|---
Safety Class| CLASS II
Declaration| CE and UKCA
Custom Tariff Number| 85044095
Notes
- If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet.
- Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75% with nominal input voltage and rated output load.
- All index testing methods in this datasheet are based on our Company’s corporate standards.
- Products are related to laws and regulations: see “Features” and “EMC”.
- Our products shall be classified according to ISO14001 and related environmental laws and regulations and shall be handled by qualified units.
References