PPSK LA-069-19ZP 250W RGBW LED Zoomable Par Light User Manual
- June 1, 2024
- PPSK
Table of Contents
250W RGBW 4in1 LED Zoomable Par Light
USER MANUAL
LA-069-19ZP 250W RGBW LED Zoomable Par Light
At first, thank you for purchasing the device. For the sake of safety and
regular operation of this projector, please read this manual carefully before
using and operating it in order to avoid any personal injury or damage to the
device.
info@oppsk.com
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR
INITIAL START-UP!
CAUTION: Keep this equipment away from rain, moisture and liquids. ****
SAFETY INSTRUCTIONS
Every person involved with the installation, operation & mainteance of this equipment should :
- Be competent
- Follow the instructions of this manual
CAUTION: Take care using this equipment! high voltage-risk of electric shock! ****
Before your initial start-up, please make sure that is no damage caused during
transportation. Shoul a there be any, consult your dealer and do not use the
equipment.
To maintain the equipment in good working condition and to ensure safe
operation, it is necessary for the user to follow the safety instructions and
warning notes Witten in this manual.
Please note ehat damages caused by user modifications to this equipment are
not subject to warranty.
ATTENTION:
DANGER OF LIFE! RISK OF BURNS!
RISK OF FIRE! RISK OF SHORT CIRCUIT!
CAUTION: DO NOT OPEN THE HOUSING SHOCK HAZARD ****
IMPORTANT:
The manufacturer will not accept liability for any resulting damager caused by
the non-observance of this manual or any unatu horized modification to the
equipment.
-
Display panel and Key definition
Menu key: Select function
Up key: parameter increment
Down key: Decreasing parameters
Confirmation key: Confirm and sa -
Menu Function
Press the menu key after powering on, and the menu menu menu menu menu table appears in turn; modify the function parameters up or down keys, and confirm that the key saves the current function and parameters (there is a power loss memory after saving).
Menu:
**** A001| | A512| Modify up or down address code(A001—A512), confirm & save
---|---|---|---
CH10| | CH18| Modify up or down DMX channel CH1/CH18, confirm & save
N000| | N084| Up or down built-in effects (N00-N084), tacitly approve N007, confirm & save
Small size0 00| | S255| Modify the speed up or down (S000-S255), tacitly approve S024, confirm & save
Soud| | Soud| Voice control mode.
R255| | R000| Adjust the brightness of red beads up or down (R000-R255), confirm & save
G255| | G000| Adjust the brightness of green beads up or down (G000-G255), confirm & save
B255| | 8000| Adjust the brightness of blue beads up or down (B000-B255), confirm & save
W255| | W000| Adjust the brightness of white beads up or down (W000-W255), confirm & save
M255| | M000| Focusing motor -
Master-slave control
There are two or more identical lamps connected by DMX three-core signal lines. All lamps are set to any address code of A001-A512, any one is set as the host, and other lamps are slaves. All slave displays do not flash. When adjusting the gradient, pulse, pulse, sound control and self-propelled effects with the host, all slave synchronous gradient, pulse, jump, sound control and self-propelled effects.
Special attention:
1. Only one host can be set up in a group of lamps. If there are multiple hosts, all lamps will flash and not be synchronized.
2. All lamps must work only when the master-slave machine is turned off when the DMX512 console is turned of -
DMX512 console
After powering on, set the address code of all lamps, and then connect all lamps to the DMX512 console in parallel with a three-core signal line, and the address code will stop flashing, indicating that the DMX512 console signal has been sent to the lamp. According to the instructions of each channel, use the DMX512 console to control the relevant functions.
CH10Channel description
** Pass
agew ay| Channe
I value| Basic functions**
---|---|---
1| 000-255| Focusing
2| 000-255| Dimming
3| 000-255| Strobe
4| 000-255| R red bead linear dimming
5| 000-255| G green bead linear dimming
6| 000-255| B Blue Bead Linear Dimming
7| 000-255| W white beads linear dimming
8| 000-255| Model
9| 000-255| Velocity
10| 000-255| Relocation: The parameter value is 250-255 reset for the whole machine, and the parameter value of 000-249 is useless and cannot be reset.
CH18Channel description****
Pass
agew ay| Channe
I value| Basic functions
---|---|---
1| 000-255| Focusing
2| 000-255| Dimming
3| 000-255| Strobe
4| 000-255| First circle of red beads
5| 000-255| First circle of green light beads
6| 000-255| First circle of blue light beads
7| 000-255| First circle of white light beads
8| 000-255| Second circle of red light beads
9| 000-255| Second circle of green light beads
10| 000-255| Second circle of blue light beads
11| 000-255| Second circle of white light beads
12| 000-255| Third circle of red beads
13| 000-255| Third circle of green light beads
14| 000-255| Third circle of blue light beads
15| 000-255| Third circle of white light beads
16| 000-255| Model
17| 000-255| Velocity
18| 000-255| Relocation: The parameter value is 250-255 reset for the whole
machine, and the parameter value of 000-249 is useless and cannot be reset.
5. technical parameters:
Voltage: AC100~240V 50/60HZ
Power: 200W
Lamp beads: 19 12W four-in- 1 LED beads
Control mode: DMX512, self-propelled, master-slave,Sound-activated, RDM.
Channel: CH10Channel,CH18Channel.
Dimming: 32bit 0~100% linear dimming
Features: Dyeing+Explosion + focus
Operating temperature: -30 degrees~50 degrees
Strobe frequency: 1~30HZ
Appearance: Metal, Black
Connection method: DMX512 input and output / power input and output.
IP rating: IP20
Size: Weight:
CAUTION: Keep this equipment away from rain, moisture and liquids. ****
Attention
- Keep the voltage of the power supply with the master light
- Do not connect with other electric cable and the DMX512 signal cable
- To ensure the earhing conductor of the switch well before connecting with AC110v~240v
- The earthing conductor is the yellow and green.
- When you move or install, to avoid the metal to knock the light
ATTENTION:
DANGER OF LIFE! RISK OF BURNS!
RISK OF FIRE! RISK OF SHORT CIRCUIT!
- Be sure to follow figures 2&3 when making your own cables.
- Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing.
- Grounding the shield could cause a short circuit and erratic behaviour.
DMX Signal Connection
3-Pin XLR to 5-pIN XLR Conversion
Conductor| 3-Pin XLR Female (OUT)| 5-Pin XLR Male (IN)
Ground/Shield| Pin 1| Pin 1
Data compliment (-signal)| Pin 2| Pin 2
Data True (1-signal)| Pin 3| Pin 3
Not Used| | Pin 4-Do Not Used
Not Used| | Pin 5-Do Not Used
MAINTENANCE
Attention:
Periodical to maintain the light
Check the screw of the spare parts in order to use well
Clearing the dusr and fragmenrs of the inner light, to keep the inner par
light clearly
Clearing the lens
More dust, smoke and granular can cause appearance of the
light corrosively,even cause overheated to damage equipment
Attention: Before take the light apart, please cut the power source.
CAUTION: Take care using this equipment! high voltage-risk of electric shock!! ****
Clearing
Cutting the power source when the light is cool, to move the cover of the
light
Using the vacuum cleaner or the gas from air compressor to remove the dust of
the appearance of the light
The lens need clearly once every week, otherwise to reduce the bright.
The fans need clear once every month,to promiss the cool effect.
Clearing the lens must be take care, decause the suface of the lens is easy to
damage and cutting, and do not wse the liquid to clean
The PCB do not use the liquid to clean, must be keep it dry, to avoid short
circuit