Operating Instructions

  • Turn the cutlery polisher on so that it is vibrating & allow it to run for 20- 30 minutes before use so that it can reach its operating temperature of 60°c o This can be monitored on the digital display or is indicated when the orange light on the front of the equipment goes out
  • Cutlery must be warm, clean & wet – the cutlery polisher cannot polish dry cutlery
  • Place cutlery into the entry chute, 8-12 pieces at a time, as soon as these are absorbed by the grain, place the next handful of cutlery into the chute
  • Cutlery will emerge from the front of the machine 20-30 seconds later, dry, polished & sanitised & will be caught in the baskets
  • Some granulate will spill into the baskets – pour this back into the polisher
  • IMPORTANT: After use the machine must be left to run for 20-30 minutes to allow the granulate to dry out and recover after use

Changing the Granulate

  • Unplug the cutlery polisher from the power supply
  • Lift the equipment lid
  • Remove used granulate from the polishing tank by hand or using a vacuum cleaner
  • Pour one new, complete fill of granulate into the polishing tank via the entry chute & grids
    • Baby Star, AS MP / Mobile – 1 Fill = 1 x 2.5kg Bag
    • AS 500 / ASK6 – 1 Fill = 1 x 3kg Bag
  • Close the equipment lid
  • Re-plug the cutlery polisher to the power supply
  • Turn the cutlery polisher back on & allow it to run for 20-30 minutes before use so that it can reach its operating temperature of 60°c
    • This can be monitored on the digital display or is indicated when the orange light on the front of the equipment goes out

Please refer to the full presentation & manual for a guide to troubleshooting
*For further assistance, grain or service please call the office on 01626 833 120

Like us on Facebook/spoonshinecutlerypolisher
Follow us on Twitter/#!/spoonshinecouk

Tel 0845 2873120
Fax 01626 835120
E-mail info@spoonshine.co.uk www.spoonshine.co.uk

Precision Hygiene Ltd Unit 4 Millwood Business Park Collett Way Newton Abbot Devon TQ12 4PH VAT Registration No. 645014464 Company Reg NO. 2888042 Registered Office Southgate House 59 Magdalen Street Exeter, Devon EX2 4HY
Company Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals