ZEBRONICS ZC2000 Monitor Mountable User Manual

June 1, 2024
ZEBRONICS

ZEBRONICS-logo

ZEBRONICS ZC2000 Monitor Mountable

Thank you for purchasing ZEB-ZC2000 Zero Client. Please read this user manual carefully before usage & save it for future reference.

Features

  • Monitor Mountable
  • Easy Maintenance
  • Enhanced Security
  • Management Software
  • Quad Core Processor

Specifications

  • Processor:  Quad Core 1.5GHz
  • RAM: 1 GB
  • Storage: 8 GB
  • Resolution: 1 920×1080@60Hz
  • 1/0 Ports: 1x DC IN Port, 1x VGA,
    • 1x HDMI, 4x USB,
    • 1 x USB 3.0, 1 x Rj45,
    • 1 x Speaker Port,
    • 1 x Microphone Port
  • Network: 10/100/1 000M Ethernet (Rj45)
  • Protocols: RDP8.0/8.1/10.0-10.6
  • Supported Serve: Windows 7/8.1/10/11 Server 2008 R2/2012 R2/2016 R2
  • Anti Theft Feature: Kensington lock
  • Product dimensions: 11×10.5×3 cm (WxDxH)
  • Net. weight: 145g
  • Country of Origin: India

Package contents

  • Zero Client: 1U
  • Power Adapter: 1U
  • QR code guide: 1U
  • Monitor Mount: 1U
  • Mounting Screws: 1U

Product image

Basic Networking

Kindly network the Zero client as per the above-mentioned diagram

Setting up the Zero Client:
Note: – You need to configure the remote desktop setup on the operating system of your computer. Please refer to the official documentation of the operating system and configure the Remote desktop protocol.

Configure your Ethernet Settings

By default, the zero client is configured in DHCP mode. If you want to assign the static IP address, Please uncheck the automatically get the IP address option and follow the below steps.

  • Step 1:- Select the Network option on the Zero client UI interface and select the wired network option.
  • Step 2: – Now Enter the Network details such as IP address, Subnet Mask, and the default gateway of the router/ switch used.
    Note: – Please assign the IP address which is freely available in the router. Assigning the same IP address will result in an IP conflict.

Configure your Display Settings

  • Step1:- Select the Display option on the Zero client UI interface and resolution option Eg:- 1366 x 768
  • Step2:- Select a Suitable resolution that matches the Native resolution of the monitor
  • Note:- The zero client supports up to 1920 x1080p video output.

Configuring your peripheral setup:­

  • Step 1 : – On the Left bottom of the screen Select the USB symbol icon to open up the peripheral menu.
  • Step 2:- Now, adjust the settings according to your preference

Connecting the servers:

Step 1:- Click on the manual add option.

Step 2:- Enter the IP details, Hostname, and Port of the server.

Step3:- Click on ok.

Zebronics Management Tool Installation Setup:-

  • Double-click to open the installer
  • Select the destination to be installed.
  • Select the necessary components to be installed.
  • Check the box if a Desktop shortcut is needed.
  • Click install to initiate the installation.

Operation

  • Double-click the Zebronics Management tool Icon to Open the Software.
  • There is no password by default.

The Main Interface

ZEBRONICS-ZC2000-Monitor-Mountable-fig-32

Screen Broadcast Settings

ZEBRONICS-ZC2000-Monitor-Mountable-fig-17

Screen Broadcast Transmission Mode| UDP broadcast, UDP multicast, UDP unicast and other modes can be selected
---|---
Screen Display Mode| You can choose the GDI and DXGI modes.

If an exception is displayed, change the mode

Audio Broadcast Switch| Select whether or not to broadcast audio, the source of the audio that has been broadcast
Screen Maximum Frame Rate| Sets the maximum frame rate for broadcast

Remove

the terminal

| Delete the existing terminal. After deleting, the terminal will rescan to connect again
---|---
Close

the terminal

| Shut off terminal power
Restart

the terminal

| Restart the terminal
Remote control terminal| Wake up the terminal, use the management computer to turn on the closed terminal, Also called wake up.
Bind the Host & User| Specify the connection information to the terminal (host and login account & password}
Connection between a Host| This is equivalent to clicking the “connect” button on the terminal
Disconnect| Disconnect the terminal from the host
Update| Patch terminal firmware updates
File Push| Push the PDF file for the terminal to display

User management

ZEBRONICS-ZC2000-Monitor-Mountable-fig-19

Create User Create a user for terminal login use
Edit User Edit user, change password
Delete User Delete corresponding user
Reset User Reset user password
Disconnect User Disconnect this user’s terminal
Logoff User Log out the corresponding user, log out, will save the

corresponding user documents & Data
Send User Message| Send a message to the corresponding user

System Settings

ZEBRONICS-ZC2000-Monitor-Mountable-fig-20

Disable all USB devices
When Turned ON, all the USB devices on the terminal will be disabled. Use with caution.

Allows a remote connection to this computer
To connect the terminal to the host, you need to turn this option ON.

Open terminal monitoring
When enabled, the terminal management interface (which may need to switch views) can dynamically display the terminal screen.

User storage Settings

ZEBRONICS-ZC2000-Monitor-Mountable-fig-21

After selecting the corresponding disk as the user’s storage space, to prevent other users from seeing it, please set the disk to be invisible to all users at the same time. Then restart the host to take effect.

Share Class
The multimedia teaching system is used with a terminal for related teaching operations, including the following functions:
Screen broadcast, student demonstration, student desktop lock, remote control, remote open software, user management, terminal management, desktop management, and other functions can greatly facilitate the use of school teaching.

ZEBRONICS-ZC2000-Monitor-Mountable-fig-22

Main Interface

ZEBRONICS-ZC2000-Monitor-Mountable-fig-23

Broadcasts

ZEBRONICS-ZC2000-Monitor-Mountable-fig-24

  • Broadcast function means broadcasting the teacher machine screen to all terminals. Supports broadcast audio
  • Click the “Screen Broadcast” button to start broadcasting, and click the “Stop Broadcast” button to stop broadcasting
  • Please be patient as this operation takes a few seconds to complete.
  • When the broadcast is turned on, the terminal screen is the same as the teacher’s screen, the parameters of the broadcast are configured in the settings interface.

Broadcasts

ZEBRONICS-ZC2000-Monitor-Mountable-fig-25

A student presentation feature broadcasts a particular student’s desktop for all terminals to view.Click the “Student Demo” button to start the demo and the “Stop Demo” button to stop it.
Note: Before clicking on the “Student Demo” button, the student terminal for the demo needs to be selected.

Remote Control

ZEBRONICS-ZC2000-Monitor-Mountable-fig-26

Click the “Remote Control” button, the remote control window will pop up, the default support for the operation terminal interface if you just want to view, please check the only view option in the settings interface. Clicking the Close button on the remote control window to exit the remote control interface.

Open Software in the terminal

ZEBRONICS-ZC2000-Monitor-Mountable-fig-27

Please select the terminal to be operated before clicking. Support for quick opening of Notepad, screen, writing pad, command prompt, browser, explorer, default player settings, etc..
Custom commands can also be run.

ZEBRONICS-ZC2000-Monitor-Mountable-fig-28

Running a custom command requires double quotation marks over the full path of the executed command, or the software will not open and supports adding this command to a drop-down menu.

Settings Interface

ZEBRONICS-ZC2000-Monitor-Mountable-fig-29

Monitor Enable| Select whether to display the terminal screen dynamically.
---|---
Refresh Interval| Dynamic display of the terminal screen refresh interval in case of terminal interface.
Bind

Network Card

| Network cards used for broadcasting.
Frame Rate| Broadcast frame rate settings.
Efficient screen capture| Efficient screenshot, Win10, Windows server 2016, 2019 systems recommend enabling this option.
Broadcast audio| Select whether to broadcast the host audio

(the sound output from the host audio interface).

Broadcast microphone| Select whether or not to broadcast

host microphone sound.

Port| Port number for remote control, typically 5900.
View Only| Whether the remote control is limited to a view-only state that is not enabled to operate the terminal desktop.
Language| Select the language in which the software will be displayed, supporting Chinese and English.

Raise Hand

ZEBRONICS-ZC2000-Monitor-Mountable-fig-30

When you click on the “Raise hand” Icon, it appears darker.

ZEBRONICS-ZC2000-Monitor-Mountable-fig-31

After clicking on it, the icons turn lighter. To cancel the “Raise hand” action, Click the icon again.
ISO 9001:2015 Certified Company www.zebronics.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>