SEALEY SAC1900 19L Oil Free Direct Drive Air Compressor User Manual

June 1, 2024
SEALEY

SEALEY SAC1900 19L Oil Free Direct Drive Air Compressor

SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-
PRODUCT

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-FIG-
\(1\)

SAFETY

ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand, and comply with the following: You must check all electrical products before use to ensure that they are safe. You must inspect power cables, plugs, sockets, and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimized by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated into the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply that is not protected by an RCCB. If in any doubt consult a qualified electrician. You must also read and understand the following instructions concerning electrical safety:

  • The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators.
  • If in any doubt about electrical safety, contact a qualified electrician.
  • Ensure that the insulation on all cables and the appliance is safe before connecting it to the power supply.
  • Ensure that cables are always protected against short circuits and overloads.
  • Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
  • Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse.
  • DO NOT pull or carry the appliance by the power cable.
  • DO NOT pull the plug from the socket by the cable.
  • DO NOT use worn or damaged cables, plugs, or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.
  • Over/current Protection: The user has to make provision for the installation of the over-current protection of the power circuit. The overcurrent protection is to be by EN 60204-1:2006
  • Electrical disconnecting device: The user has to make provisions for the installation of the electrical disconnecting device of the power circuit.
  • The supply disconnection device is to be by EN 60204-1:2006.
    NOTE: If using a transformer to supply the compressor, it must be rated at a minimum of 2kVA to allow the compressor to run efficiently.

GENERAL SAFETY

  • Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
  • Familiarise yourself with the application and limitations of the compressor.
  • The operation must be with all guards, covers, lids, and enclosures correctly in place.
  • This compressor has not been designed for commercial, trade, or industrial applications. The warranty will be voided if the machine is used in commercial, trade, or industrial businesses or for equivalent purposes.
  • Fully assemble the compressor before using it for the first time.
  • The concentration of processed gases that can displace breathing air shall be kept within acceptable levels. Reference EN 12021 for acceptable levels of contaminants in breathing air.
  • The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user/operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
  • Remove from mains supply when performing maintenance or inspections.
  • Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service agent.
  • Delivery hoses should be fitted with a safety cord. It is essential to use separators, water traps, and drains which process the liquids produced by the compressor system is put into operation.
  • The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +5°C to +40°C). Ensure there is no dust, acids, vapors, explosive gases, or inflammable gases in the room.
  • WARNING! The compressor must only be serviced by an authorized agent. DO NOT tamper with, or attempt to adjust, the pressure switch or safety valve.
  • Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented.
  • Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorized parts may be dangerous and will invalidate your warranty.
  • Read the instructions relating to any accessory to be used with this compressor. Ensure the safe working pressure of any air appliance used exceeds the compressor’s output pressure.
  • If using a spray gun, check that the area selected for spraying is provided with an air change/ventilation system.
  • Ensure the air supply valve is turned off before disconnecting the air supply hose.
  • To move the compressor use the handle only. Maintain the unit’s center of gravity when lifting. DO NOT attempt to lift or move the compressor by any other means.
  • Use the compressor in a well-ventilated area and ensure it is placed on a firm surface.
  • Keep tools and other items away from the compressor when it is in use, and keep the area clean and clear of unnecessary items.
  • Ensure the air hose is not tangled, twisted, or pinched.
  • Keep children and unauthorized persons away from the working area.
  • DO NOT disassemble the compressor for any reason. The unit must be checked by qualified personnel only.
  • DO NOT use the compressor outdoors, or in damp, or wet, locations.
  • DO NOT operate within the vicinity of flammable liquids, gases, or solids.
  • DO NOT touch the compressor cylinder, cylinder head, or pipe from head to tank as these may be hot.
  • DO NOT use this product to perform a task for which it has not been designed.
  • DO NOT deface the certification plate attached to the compressor tank.
  • DO NOT cover the compressor or restrict airflow around the unit whilst operating.
  • DANGER! DO NOT direct the output jet of air towards people or animals.
  • DO NOT operate the compressor without an air filter.
  • DO NOT allow anyone to operate the compressor unless they have received full instructions.
  • WARNING! The air tank is a pressure vessel and the following safety measures apply:
  • DO NOT tamper with the safety valve, DO NOT modify or alter the tank in any way DO NOT strap anything to the tank, DO NOT weld the tank.
  • DO NOT subject the tank to impact, vibration, or heat, and DO NOT allow contact with abrasives or corrosives.
  • Drain condensation from the tank daily.
  • WARNING! If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.
  • When not in use, store the compressor carefully in a safe, dry, childproof location.

INTRODUCTION

Low noise compressor runs at only 79dB(A), suitable for places where a standard compressor would disturb work or people in the vicinity. Aluminum cylinder head with cast iron cylinder gives added resistance to wear. Fitted with a fully automatic pressure cut-out switch and twin gauges displaying tank and working pressures. The pump head is directly coupled to a heavy-duty induction motor for reliable and quiet operation. Precision welded receiver tank manufactured to meet Pressure Vessel Directive. Fitted with two outputs so multiple tools can be used at once. Suitable for use with the Sealey range of air nailers. Tube chassis and painted metal step, perfect for construction and automotive applications. The benefits of oil-free compressors include easy maintenance, reduced noise levels, better efficiency, quieter when running, and no oil contamination in the air supply. Lightweight unit with extendible handle and solid plastic wheels with rubber grip.

CONTENTS

SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-FIG-
\(2\)

  • A – Electrical Motor
  • B – Air Compressor Pump
  • C – Safety Valve
  • D – Pressure Switch
  • E – Air Pressure Regulator
  • F – Tank Pressure Gauge
  • G – Outlet Pressure Gauge
  • H – Quick Coupler
  • I – Drain Valve
  • J – Air Tank
  • K – Power Cord

PARTS DESCRIPTION

PARTS DESCRIPTION

A| Electric Motor| The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut it down to prevent the motor from being damaged.
B| Air Compressor Pump| The pump compresses the air and discharges it into the tank via the piston that moves up and down in the cylinder.
C| Safety Valve| This valve is used to prevent the compressor from building too much pressure. If the pressure reaches the present level of the motor, it will automatically pop open.
 | D| Pressure Switch| This switch turns on the compressor and is operated manually. When in the ON position, it allows the compressor to start up or shut down automatically, without warning, upon air demand. ALWAYS set this switch to OFF when the compressor is not being used and before unplugging the compressor.
---|---|---|---
E| Air Pressure Regulator| The regulator is used to adjust the pressure inside the line to the tool that is being used. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease the pressure.
F| Tank Pressure Gauge| The gauge measures the pressure level of the air that is stored in the tank. It cannot be adjusted by the operator and it does not indicate the pressure inside the line.
G| Outlet Pressure Gauge| The gauge measures the regulated outlet pressure.
H| Quick Coupler| The quick coupler is connected to a quick connector which connects to the air hose.
I| Drain Valve| The drain valve is used to remove moisture from the air tank after the compressor is shut off.
J| Air Tank| The tank is where the compressed air is stored.
K| Power Cord| This product is for use on a nominal 240-volt circuit and should be grounded. A cord with a grounding plug as illustrated must be used. Make sure that the product is connected to an outlet that has the same configuration as the plug. No adapter should be used with this product. Check with a licensed electrician if the grounding instructions are not understood or if there is doubt as to whether the product is properly grounded. Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a licensed electrician.

SPECIFICATION

MODEL NO: SAC1900
Air Displacement cfm(L/min): 7.16(203)
Flow Rate 105L/Min@6.2bar
Full Load Current 6A
Fuse Rating: 13A
Inlet Intermediate Pressure/Temperature Normal environment
Inlet Discharge Pressure 8-10 bar
Maximum Free Air Delivery cfm(L/min): 4.6(130)

1.8m
Maximum Speed of Unit| 1455rpm| Pressure| 8-10 bar
Maximum Pressure:| 145psi(10bar)| Receiver Capacity:| 19L
Motor Output:| 1.5hp| Size (W x D x H):| 550mm x 340mm x 715mm
Maximum Free Air Delivery cfm(L/min):| 4.6(130)| Supply:| 230V/13A 50Hz

PREPARATION

UNPACKING THE COMPRESSOR

  • Unpack the air compressor unit. Inspect the unit for damage. If the unit has been damaged, contact the retailer immediately.
  • Check the air compressor’s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its intended use.
  • The carton should contain the air compressor and owner’s manual.
  • POSITIONING OF THE AIR COMPRESSOR (FIG.1)SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-FIG- \(3\)
  • Position the air compressor (1) near an electrical outlet (2).
  • The compressor must be at least 12”(31cm) from any wall (3) or obstruction, in a clean, well-ventilated area to ensure sufficient airflow and cooling.
  • Place the air compressor on the floor or a hard, level surface. The air compressor must be level to ensure proper drainage of the moisture in the tank.
  • CONNECT THE AIR HOSE TO THE COMPRESSOR (FIG.2)
  • Connect the air hose (1) to the compressor’s quick coupler (2) with the quick connector (3).
  • NOTE: Air hose and quick connector are not provided and need to be purchased separately. Apply PTFE tape on all the threads to prevent air leakage.
  • WARNING! High-pressure air could result in death or serious injury. Never operate above the maximum operating pressure of the spray gun or tool.
  • WARNING! Hot compressor surfaces could result in serious injury. Allow the compressor to cool before touching it.
  • NOTE: If the pump has been transported or turned upside down (even partially), allow the pump to sit in a normal, upright position for approximately 10 minutes before starting.
  • WARNING! Risk of serious eye injury from moisture and debris. Always wear CE safety goggles when opening the drain valve.
  • WARNING! High-pressure air could result in death or serious injury. Shut off the unit, unplug, and release air pressure before servicing.
  • CAUTION: High-pressure air containing water condensation could result in minor or moderate injury. Do not spray at any person.

BREAK IN THE PUMP

  • Set the pressure switch to the OFF position (fig.3).SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-FIG- \(5\)
  • Open the tank drain valve by turning it counter-clockwise to permit the air to escape and prevent air pressure build-up in the air tank during the break-in period (fig.4).
  • Turn the air pressure regulator knob clockwise until it stops (fig 5).
  • Plug in the power cord
  • Use a dedicated circuit. The compressor will use the full capacity of a typical 10A household circuit.
  • If any other electrical devices are drawing from the compressor’s circuit, the air compressor may fail to start voltage or an overloaded circuit can result in sluggish starting that causes the motor overload protection system or circuit breaker to trip, especially in cold conditions. Disconnect the power cord only after the break-in process has been completed, otherwise, the motor might get damaged.
  • Set the pressure switch to the ON position. The compressor will start. Run the compressor for 30 minutes. If it fails, turn it off immediately.
  • NOTE: Breaking in the unit is only required before first use.
  • After 30 minutes, turn off the pressure switch.
  • Close the tank drain valve by turning it clockwise (fig 4).
  • Set the pressure switch to the ON position. The air receiver will fill to “cut-out” pressure and then the compressor’s motor will stop. The compressor is now ready for use.

BEFORE EACH START-UP

  • Set the pressure switch to the OFF position (fig.3).
  • Turn the air pressure regulator knob counter-clockwise until it stops (fig.5).
  • Attach hose and accessories (sold separately).

HOW TO START

  • Close the tank drain valve (fig.4).
  • Plug in the power cord.
  • Set the pressure switch (fig.3) to the ON position and allow the tank pressure to build.
  • The motor will stop when tank pressure reaches cutout pressure.
  • Turn the air pressure regulator knob (fig.5) clockwise until the desired pressure is reached.
  • The compressor is ready for use.

HOW TO SHUT DOWN

  • Set the pressure switch to the OFF position (fig.3).
  • Unplug the power cord.
  • Set the tank drain valve to ON to ensure the tank is drained (fig.4).

MAINTENANCE

  • WARNING! Disconnect from all energy supplies before servicing.
  • WARNING! Display warning signs against reconnection whilst the compressor is being repaired such as:SEALEY-SAC1900-19L-Oil-Free-Direct-Drive-Air-Compressor-FIG- \(6\)
  • WARNING! Air contaminants taken into the compressor will affect optimum performance.
  • Example: Body filler dust or paint overspray will clog the pump intake filter and may cause internal damage to pump/motor components.
  • Please note that any parts damaged by any type of contamination will not be covered by warranty.

DAILY MAINTENANCE
Drain the tank. Through normal operation of your air compressor, condensation of water will accumulate in the tank. To prevent corrosion of the tank from the inside, condensation must be drained at the end of every workday. Be sure to wear protective goggles.
Relieve the air pressure in the system then open the drain valve on the bottom of the tank to drain. Under cold conditions, it is especially important to drain the tank after each use to reduce the chance of problems resulting from the freezing of condensation water. NOTE: Refer to 7.5 on how to drain the tank. Pressure relief valve. Loosen the knob at the top of the safety valve to ensure normal exhaust. Tighten it again and remove any debris.

MONTHLY MAINTENANCE
Test for leaks. Check that all connections are tight. Small leaks in the tank, hoses, connections, or transfer tubes will substantially reduce the air compressor and tool performance. Spray a small amount of soapy water around the area of suspected leaks with a spray
bottle. If bubbles appear, repair, replace, or reseal the faulty component. Do not over-tighten any connections.

BEFORE STORING
Before storing the air compressor:

  • Drain tank.
  • Use an air blow gun to clean all dust and debris from the compressor.
  • Disconnect and wind up the power cord.
  • Clean the ventilation openings on the motor enclosure with a damp cloth.
  • Drain all moisture from the tank.
  • WARNING! Storage covers could cause a fire resulting in death or serious injury.
  • DO NOT place a storage cover over a hot air compressor.
  • Let the equipment cool for a sufficient time before placing the cover on the equipment.

STORAGE

  • Store the air compressor in a clean and dry location.
  • In cold weather, store the compressor in a warm building when it is not in use.
  • This will reduce problems related to starting the motor and the freezing of water condensation.

HOW TO DRAIN TANK

  • Set the pressure switch to the OFF position.
  • Unplug the power cord.
  • Turn the air pressure regulator knob counter-clockwise to set the outlet pressure to zero.
  • Place a suitable container under the unit to catch water.
  • Slightly tilt the unit and turn the drain valve counter-clockwise to open.
  • After the water has been drained, close the drain valve(clockwise). The air compressor can now be stored.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
The motor will not run or start. The power cord is not plugged in. Plug the

power cord into a grounded outlet.
The pressure switch is in the OFF position.| Set the pressure switch to the ON position.
The extension cord is the wrong wire gauge or is too long?| Check extension cord information for the proper wire gauge and cord length.
The motor’s thermal overload protection has tripped.| Turn the air compressor off, unplug the power cord, and wait until the motor has cooled down. Plug in the power cord only after the motor has cooled

down, and wait at least 5 minutes to make sure the

thermal overload protector has recovered.

A fuse has blown or a circuit breaker has been tripped.| Replace the fuse or reset the circuit breaker.
Verify that the fuse has the proper amperage.
Check for low voltage conditions.
Disconnect any other electrical appliances from the circuit or operate the compressor on a dedicated circuit.
The air tank pressure exceeds the preset pressure switch limit.| The motor will start automatically when the tank pressure drops below the cut-in pressure.
The safety valve is stuck open.| Clean or replace the safety valve.
Electrical connections are lost.| Contact an authorized service center
The motor, capacitor, or safety valve is defective.| Contact an authorized service center
The motor runs continuously when the pressure switch is in the ON position.| The pressure switch does not shut off the motor when the air compressor reaches the cut-out pressure and the safety valve activates.| Set the pressure switch to the OFF position. If the motor does not shut off, unplug the air compressor. If the pressure switch is defective, replace it.
The compressor’s capacity is not enough.| Check the air requirements of the accessory that is being used. If it is higher than the L/MIN and pressure supplied by the compressor (page 2), a larger capacity air compressor is needed. Most accessories are rated at 25% of actual

L/MIN while running continuously.

The regulator does not regulate the pressure.| The regulator or its internal parts are dirty or damaged.| Replace the regulator.
The pressure is low or there is not enough air.| There is a leak at one of the fittings.| Check the fittings with soapy water. Tighten or reseal leaking fittings (apply plumber’s tape on threads). Do not over-tighten.
---|---|---
The tank drain valve is open.| Close the drain valve.
The air intake is restricted.| Clean or replace the air filter element.
Prolonged excessive use of air.| Decrease the amount of air used.
There is a hole in the air hose.| Check the air hose and replace it if necessary.
The tank leaks.| Replace the tank immediately. Do not attempt to repair it.
The valve is leaking.| Check for worn parts and replace them if necessary.
There is moisture in the discharge air.| There is condensation in the air tank caused by a high level of atmospheric humidity or because the air compressor has not been running long enough.| Drain the air tank after each use. Drain the air tank more often in humid weather and use an air-line filter.
The compressor overheats.| The ventilation is inadequate.| Relocate the compressor to an area with cool, dry, and well-circulated air.
Cooling surfaces are dirty.| Clean all cooling surfaces on the pump and the motor thoroughly.
The valve is leaking.| Replace worn parts and reassemble using the new plumber’s tape.

ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a manner that is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations. REGISTER YOUR

WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of which is required for any claim.