PCE INSTRUMENTS PCE-LMD 5 Lux Meter User Manual
- June 11, 2024
- PCE Instruments
Table of Contents
**PCE INSTRUMENTS PCE-LMD 5 Lux Meter User Manual
**
Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.
-
- The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
-
The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
-
Do not expose the device to shocks or strong vibrations.
-
The case should only be opened by qualified PCE Instruments personnel.
-
Never use the instrument when your hands are wet.
-
You must not make any technical changes to the device.
-
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
-
The device must only be used with accessories from PCE Instruments or equivalent.
-
Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
-
Do not use the instrument in explosive atmospheres.
-
The measurement range as stated in the specifications must not be exceeded under any circumstances.
-
Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this
manual.
We expressly point to our general guarantee terms which can be found in our
general terms of business.
If you have any questions please contact PCE Instruments. The contact details
can be found at the end of this manual.
Delivery scope
1 x lux meter PCE-LMD 5 or PCE-LMD 10 incl. lux sensor
1 x USB cable
1 x PC software (PCE-LMD 10)
1 x service bag
1 x user manual
Accessories
USB mains adapter NET-USB
Technical data
Specifications
Measurement range | 0 … 400 kLux 0 … 40 kfc |
---|---|
Accuracy | ±5 % of measured value ±10 digits at standard light A ±10 % of |
measured value ±10 digits
Repeatability| ±2 %
Sampling rate| 4 Hz
Sensor| Silicon photodiode with spectral filter
Peak Hold| Detection of the peak light intensity of the shortest 10 pS
Battery level indicator| flashes when the battery voltage is too low
Data logger (PCE-LMD 10)| 32,000 sets of measured values
Power supply| 3.7 V Li-Ion battery
Operating conditions| -10 … 50 °C / <80 % RH
Storage conditions| -20 … 50 °C / <80 % RH
Dimensions| Meter: 162 x 88 x 32 mm (6.38 x 3.46 x 1.26 “) Sensor: 102 x 60 x
25 mm (4.01 x 2.36 x 0.98”)
Weight| approx. 320 g (0.70 Ibs)
Sensitivity
Device description
Key description
- Sensor cable
- LCD
- Zero calibration key
- HOLD key
- ON/OFF key
- Key for switching the unit
- REL key (relative value)
- PEAK key
- MIN key (PCE-LMD 5) / MIN/MAX key (PCE-LMD 10)
- MAX key (PCE-LMD 5) / REC key (PCE LMD 10 only)
- Light sensor
Notice: The micro USB socket is located at the bottom of the meter.
Display
- MAX/MIN value
- Relative value
- PEAK value MAX/MIN
- Freeze data
- Analogue bar graph
- Digital display
- Icon for data storage
- Unit : FC/LUX
- Battery icon
- Icon for full memory
- USB icon
- Automatic power off
Operating instructions
Sensor
The light sensor is firmly connected to the meter by a spiral cable. Open the
sensor protection cap, leaving the white sensor dome fully exposed. To avoid
scratches and damage to the sensor dome, replace the protective cap when the
meter is not in use.
6.2 Switch on/off the meter
Press and release the key to turn on the light meter and press and hold the
same key for 3 seconds to turn off the light meter.
Select units
Press the key to select LUX or FC (Foot Candle) as the unit for
measurements.
Measurement
Open the sensor protection cap.
Position the sensor at a point perpendicular to the light source.
Read the value on the LCD.
Note: During the measurement, make sure that no shadow or reflective
light enters the light sensor dome.
Max/Min mode
- Press the MAX (PCE-LMD 5) or MAX/MIN (PCE-LMD 10) key once. The “MAX” icon will appear on the LCD and the maximum value will be displayed on the LCD until a higher value is measured.
- Press the MIN (PCE-LMD 5) or MAX/MIN (PCE-LMD 10) key again. The “MIN” icon will appear on the LCD and the minimum value will be displayed on the LCD until a lower value is measured.
- Press the MAX/MIN key again. The MAX MIN icon will flash on the LCD and the realtime value will be displayed. Now the MAX and MIN values are recorded.
- Press the MAX/MIN key again. This will take you back to step 1.
- To exit the MAX-MIN mode, press and hold the MAX/MIN key for approximately 2 seconds until the “MAXMIN” icon disappears from the LCD.
Hold data
Press the “HOLD” key. The digital reading is held and the “HOLD” icon appears
on the LCD.
Press the “HOLD” key again to return to normal operation.
Note: When the Data Hold function is activated, the analogue bar graph
above the measured value changes according to the current light intensity.
Hold a PEAK value
The peak hold function allows the lux meter to detect the light pulse rising
or falling to 10 µs.
- Press the PEAK key. The “Pmax” icon will appear on the LCD. The lux meter measures the MAX light pulse and displays the MAX value. The data will be updated until a higher value is detected.
- Press the PEAK key again. The “Pmin” icon will appear on the LCD. The lux meter will display the MIN light pulse value. The data will be updated until a lower value is detected.
- To exit the Peak Hold function, press the PEAK key for approximately 2 seconds until the “Pmax” or “Pmin” icon disappears from the LCD.
Relative value
The relative value is the difference in value between the current light value
and the saved reference light value.
To save a reading as a reference light value, press the REL key when the
desired reference value is displayed on the LCD. The value displayed
thereafter will be the relative value of that saved value.
For example: with the saved reference value 80 lux, if the current light value
is 100 lux, the meter will display 20 lux. To retrieve the reference value,
press the REL key again. The value will be displayed and the REL icon will
flash on the LCD.
To exit REL mode, press and hold the REL key for approximately 2 seconds until
the REL icon on the LCD disappears.
Back light
If no key is pressed for 60 seconds in APO (auto power off) mode or recording
mode, the back light will automatically dim to save battery power. Press any
key to increase the brightness again. In non-APO mode, the back light is
always very bright.
Recording mode (PCE-LMD 10 only)
The lux meter has a data logging function. Before starting the recording
function, connect the light meter to the PC via Micro-USB and set up the
parameters via the Smart Logger software. Set the start mode to “by key” and
disconnect the light meter from the PC after setup. Press the REC key on the
lux meter to start recording. The REC icon will start flashing and will be
displayed on the LCD.
Do not turn off the meter during recording mode. When the set number of data
is reached, the lux meter will be turned off automatically. When the memory is
full, the FULL icon appears at the bottom of the LCD. When enough data have
been deleted, the FULL icon disappears.
Notice: If the lux meter is turned off during recording, connect it to
the PC and set up the parameters again after turning it on before starting
recording again. Otherwise, the ERR icon will be displayed on the LCD when you
press the REC key for recording.
Auto Power Off
The APO function is set to ON by default. To turn off the APO function, press
the key lightly.
To extend the battery life, the lux meter will automatically turn off after
about 10 minutes when not in use.
In record mode or when the meter is connected via USB, the APO function is
automatically disabled until the memory is full or the set number of records
is reached.
Zero point calibration
If value drift occurs after prolonged use of the light meter, it can be
calibrated with the zero calibration function.
Cover the sensor dome with the sensor protection cap.
Press the zero key. The “CAL” icon will appear on the LCD.
Press the Zero key until the “CAL” icon disappears from the LCD, then release
the key when 0.0 lux is displayed.
Note: If the light sensor is not covered, “ERR” is displayed when the
zero key is pressed.
Maintenance and cleaning
- Cleaning and storage
- The white plastic sensor dome should be cleaned with a damp, soft cloth if necessary.
- Store the light meter in an area with moderate temperature and relative humidity.
- Charging the battery
When the battery power is insufficient, the battery icon appears on the LCD and flashes. Use the DC 5V power adaptor to connect to the micro USB charging port on the bottom of the meter. The battery icon on the LCD will indicate that the battery is charging and will disappear when the battery is fully charged.
Warranty
You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms.
Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the
European Parliament applies. Due to the contained pollutants, batteries must
not be disposed of as household waste. They must be given to collection points
designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back.
We either re-use them or give them to a recycling company which disposes of
the devices in line with law. For countries outside the EU, batteries and
devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
PCE Instruments contact information
United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL
USA
Tel: +1
561-320-9162">561-320-9162
Fax: +1
561-320-9176">561-320-9176
info@pce-americas.com
www.pce-instruments.com/us
****
References
- France.fr : Explore France and its wonders - Explore France
- iberica.es
- Make an offer on the domain instruments.co.uk - Domains.co.uk
- Computer Instruments | Home
- Discover Italy: Official Tourism Website - Italia.it
- PCE Teknik Cihazlar Paz. Tic. Ltd.Şti. | PCE Instruments
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>