VOLLRATH 3667101D Hot and Cold Food Well Unit Instruction Manual
- June 1, 2024
- VOLLRATH
Table of Contents
Outpertfrom every day
Operator’s Manual
3667101D Hot and Cold Food Well Unit
1 WELL, 2 WELL, 3 WELL, AND 4 WELL HOT/COLD DROP-IN (NSF7 Cold Food Holding and NSF4 Hot Food Holding)
Item| Description| Heater Watts (per well)|
Compressor| Max Amps Draw| Voltage| Plug
---|---|---|---|---|---|---
HP| Refrigerant
3667101D| 1 Well Hot/Cold Drop-in, Top Mount| 625W| 1/4 hp| R404| 6.0| 120V|
5-15P
3667101U| 1 Well Hot/Cold Drop-in, Bottom Mount
3667102D| 1 Well Hot/Cold Drop-in, Top Mount| 120/208-240V| 14-20P
3667102U| 1 Well Hot/Cold Drop-in, Bottom Mount
3667201D| 2 Well Hot/Cold Drop-in, Manifold Drain| 11.2| 120V| 5-15P
3667201DA| 2 Well Hot/Cold Drop-in, Auto Drain
3667202D| 2 Well Hot/Cold Drop-in, Manifold Drain| 8.6| 120/208-240V| 14-20P
3667202DA| 2 Well Hot/Cold Drop-in, Auto Drain
3667301D| 3 Well Hot/Cold Drop-in, Manifold Drain| 16.0| 120V| 5-20P
3667301DA| 3 Well Hot/Cold Drop-in, Auto Drain
3667302D| 3 Well Hot/Cold Drop-in, Manifold Drain| 11.2| 120/208-240V| 14-20P
3667302DA| 3 Well Hot/Cold Drop-in, Auto Drain
3667402D| 4 Well Hot/Cold Drop-in, Manifold Drain| (2) 1/4 hp| 14.0|
120/208-240V| 14-20P
3667402DA| 4 Well Hot/Cold Drop-in, Auto Drain
Thank you for purchasing this Vollrath equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Safety Precautions
To ensure safe operation, read the following statements and understand their meaning. This manual contains safety precautions which are explained below. Please read carefully.
WARNING
Warning is used to indicate the presence of a hazard that will or can cause
severe personal injury or death.
CAUTION
Caution is used to indicate the presence of a hazard that will or can cause
minor or major personal injury if the caution is ignored.
NOTICE is used to note information that is important but not hazard-
related.
These precautions should be followed at all times. Failure to follow these
precautions could result in injury to yourself and others.
To reduce risk of injury or damage to the equipment:
- Use only grounded electrical outlets matching the nameplate rated voltage.
- Do not use an extension cord with this equipment. Do not plug this equipment into a power strip or multi-outlet power cord.
- Keep equipment and power cord away from open flames, electric burners or excessive heat.
- Do not operate if equipment has been damaged or is malfunctioning in any way.
- Unit should only be used in a flat, level position.
- Do not operate hot well without water.
- Do not use food pans deeper than 6” (15.2 cm).
- Do not place any hot items on the top surface.
Function and Puroose
This unit is intended and designed to keep food at proper serving
temperatures. This unit is made for use in an ambient temperature below 86 °F
(30 °C). Using in warmer temperatures will take unit out of NSF compliance.
Modifying refrigeration parameters may void the warranty.
Hot food stations are not intended or designed to cook raw food or to reheat
prepared food. Cold food stations are not intended or designed to cool or
chill food. Food must be prepared and placed in food stations at proper
serving temperatures. Refrigerated cold stations are best used for holding
periods up to four hours. For best performance, stainless steel containers are
recommended.
This equipment is not intended for household, industrial or laboratory use.
Unpacking the Equipment
- Remove all packing material and tape, as well as any protective plastic from the equipment.
- Clean any glue residue left over from the plastic or tape.
- Dispose all packaging materials in an environmentally responsible manner.
Installation
This unit must be installed on a dedicated electrical circuit in accordance with local codes. Installation must be qualified service personnel.
Clearance Requirements
- One, two and three well drop-ins are zero clearance on all sides.
- Four well drop-in requires zero clearance on sides and 1 1/2” clearance at the bottom.
Venting requirements
The Hot/Cold Drop-ins must have adequate ventilation. Minimum requirements are
listed in the table below.
Drop-in | Number of cutouts | Size |
---|---|---|
Intake | Discharge | |
One Well | 1 | 1 |
Two Well | 1 | 1 |
Three- Well | 1 | 1 |
Four-Well | 2 | 2 |
The preferred location for the venting cutouts is on the short ends of the cabinet. If the short end are not available the long sides can be used. See drawings below. When louvers are installed in the long sides, Vollrath recommends using a fan to assist air movement.
Control Box Mounting
Controls must be mounted on the operator side (raceway side) for proper
orientation with wells. The control box requires 3″ of depth in the cabinet
when using the included frame. Without the frame, the control box requires 4″
of depth in the cabinet.
Control Box Cutout Dimensions
Model | Cutout Dimension |
---|---|
One Well Drop-in | 7″ x 8” |
Two Well Drop-in | 7″ x 10-1/2″ |
Three Well Drop-in | 7″ x 13″ |
Four Well Drop-in | 7″ x 15-1/2″ |
Controt Box Locations
Hot/Cold Well Drop-in Cutout Dimensions
Model | Cutout Dimension |
---|---|
One Well Top Mount Drop-in | 25-1/4″ x 17-5/16″ |
One Well Bottom Mount Drop-in | Per customer specification for amount of |
visible top flange
Two Well Drop-in| 25-1/4″ x 40-3/4″
Three Well Drop-in| 25-1/4″ x 54″
Four Well Drop-in| 25-1/4″ x 67-1/4″
NOTICE: Well cutouts must have a corner radius of 7/8″.
NOTICE: Control cutouts must have a corner radius of 3/8″.
Seal the Flang
Top Mount
- Place a bead of silicone sealer rated at a minimum of 450 °F (232 °C) around the well flange to prevent water from leaking into control areas.
- Set the clips into slots
- Tighten the thumbscrews slowly and in an alternating pattern to evenly compress the silicone.
Bottom Mount
Place a bead of silicone sealer rated at a minimum of 450 °F (232 °C) between
the countertop and the inside of the well to prevent water from leaking into
control areas, and in mounting holes when using rivets or other fasteners.
Controls
A ON/OFF SWITCH. Switches the equipment power “ON” or “OFF”.
B MODE SELECTOR SWITCH. The down position selects refrigeration mode. The
up position selects heating mode The center position selects neutral mode.
When the switch is in the center or up positions, the drain valve will be
closed.
C REFRIGERATION INDICATOR LIGHT. Illuminates when the unit is in the
refrigeration mode.
D TEMPERATURE CONTROL DIAL (Hot Mode Only). Used to set or adjust the hot
temperature of the well. The higher the number the higher the temperature, the
lower the number the lower the temperature.
E HEATING INDICATOR LIGHT. Illuminates when the unit is in the heating
mode.
Operation
| WARNING
---|---
Electrical Shock Hazard.
Keep water and other liquids from entering the inside of the unit. Liquid
inside the unit could cause an electrical shock
Do not over fill wells, pans or trays. Liquid could contact the electrical
components and cause a short circuit or an electrical shock. Unplug unit
before performing service, draining or removing spillage pans and trays. Do
not spray water or cleaning products. Do not use a power cord that has been
modified or damaged.
NOTICE: Before using this equipment it must be cleaned and dried
thoroughly.
NOTICE: For best performance, prevent drafts or room air currents from
disturbing the curtain of hot or cold air above the food pans.
Refrigerated Mode
NOTICE: When switching from hot mode to refrigerated mode, turn the mode
selecting switch to the neutral mode center position. Remove the hot food
pans. Remove the drain plug or switch to cold mode and drain water from the
system. Drain the hot water before beginning refrigerated mode.
-
Plug the equipment into a properly grounded electrical supply matching the nameplate rating. Damage to the equipment can occur if incorrect power is supplied to equipment.
-
Turn the on/off switch to the “ON” position.
-
Turn the mode selector switch to the down position. This will open the drain valve on models with auto-drains. On units with manual drain plugs, remove the drain plug. Units do not have an adjustable temperature setting.
-
Allow the unit to run for approximately 60 minutes.
For the best performance when using ice with this unit, allow unit to run for approximately 2 hours before adding ice. This will help the ice remain solid. -
Place containers of properly chilled food into the pre-chilled unit.
-
Regularly check the food temperature.
NOTICE: Monitor food temperature closely for food safety. The United States Public Health Service recommends that cold food be held at a maximum of 41 ºF (5 ºC) to help prevent bacteria growth. -
When finished using the unit, turn the mode selector switch to the middle position and turn the on/off to the “OFF” position. Remove the food containers.
Heating Mode
| CAUTION
---|---
Burn Hazard.
Do not touch heating surfaces, liquid, or food while unit is heating or
operating.
Hot food, steam and liquids can burn skin. Allow the hot liquid, spillage pans
and trays to cool before handling. Use gloves, mitts or pot holders if it is
necessary to handle hot pans.
- Plug the equipment into a properly grounded electrical supply matching the nameplate rating. Damage to the equipment can occur if incorrect power is supplied to equipment.
- Turn the on/off switch to the “ON” position. Turn the mode selector switch to the up position.
- Fill the well to the correct level with clean fresh water. The correct level is about 1” (2.5 cm) from the bottom. Always maintain water in the well. Do not over fill. Allowing the well to run dry during operation may reduce the service life of the equipment.
- Preheat the water in the wells by covering wells with empty food containers or covers. Turn the heat control to the maximum heat setting. Preheat for 60 minutes.
- Place container of hot food product, above 140 °F (60 °C), into preheated equipment.
- Reduce heat setting to a level that will maintain a safe holding temperature and maintain food quality.
NOTICE: Monitor food temperature closely for food safety. The United States Public Health Service recommends that hot food be held at a minimum of 140 ºF (60 ºC) to help prevent bacteria growth. Maintain correct water level and temperature setting. Periodically remove food container and check the water level. Add water if needed.
During operation
- Maintain water level. Periodically (approximately 2 hours) remove container of food and check the water level. Add hot water if needed.
When Finished Ussng the Equipment
-
Turn the mode selector switch to the center position. Turn the on/off switch to the “OFF” position.
NOTICE: When the selector switch is in the center position or the hot position the drain valve will be in the closed position. -
When finished using the unit, remove the food containers.
-
When removing hot food containers from unit use gloves, mitts or pot holders to protect hands.
-
Allow the unit and water to cool completely before cleaning.
Cleaning
To maintain the appearance and increase the service life, clean your equipment
daily.
NOTICE: Do not use caustic cleaning chemicals, steel wool or commercial
lime removal products to clean the equipment.
-
Remove the food containers.
-
If the drop-in was in heating mode, drain the water.
• If the unit has an automatic drain, turn the mode selector switch to cold mode. This will allow the water to drain. Turn the ON/OFF switch to the “OFF” position.
• If the unit has a manual drain, turn the ON/OFF switch to the “OFF”position. Let the water in the wells cool. Remove the drain plug to drain the water. -
Let hot wells cool before cleaning.
-
Use a damp cloth or sponge dipped in soapy water to clean the inside of the well and the outside of the equipment.
-
Thoroughly rinse equipment with water after cleaning.
Problem | It might be caused by | Course of Action |
---|---|---|
**** Unit does not have power. | Unit is not plugged in. | Plug unit in. |
Power switch is in the “OFF” position. | Turn power switch to the “ON” |
position.
Circuit breaker is tripped.| Reset the circuit breaker.
Defective circuit or in-adequate power supply.| Call licensed electrician.
Unit has power but is not operating.| Unknown.| Contact Vollrath Technical
Services 800-632-0832.
**** Unit does not heat or chill correctly.| Drafts or room air currents
disturbing the curtain of hot or cold air immediately above the food pans|
Eliminate drafts and room air currents.
Service and Repair
There are no user serviceable parts within this appliance. To avoid serious
injury or damage, never attempt to repair the unit or replace a damaged power
cord yourself. Do not send units directly to The Vollrath Company LLC. Please
contact Vollrath Technical Service from the list below.
VOLLRATH Technical Service •
1-800-628-0832 • Email:
techservicereps@vollrathco.com
When contacting Vollrath Technical Service, please be ready with the item
number, model number (if applicable), serial number, and proof of purchase
showing the date the unit was purchased.
Warranty Statement for the Vollrath Co. L.L.C.
This warranty does not apply to products purchased for personal, family or
household use, and The Vollrath Company LLC does not offer a written warranty
to purchasers for such uses.
The Vollrath Company LLC warrants the products it manufactures or distributes
against defects in materials and workmanship for a period of one year, except
as specifi cally described in our full warranty statement. In all cases, the
warranty runs from the date of the end user’s original purchase date found on
the receipt. Any damages from improper use, abuse, modifi cation or damage
resulting from improper packaging during return shipment for warranty repair
will not be covered under warranty.
For complete warranty information, product registration and new product
announcement, visit www.vollrath.com.
www.vollrath.com
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI
53081-3201 U.S.A.
Main Tel: 800.628.0830
Fax: 800.752.5620
Technical Services: 800.628.0832
Service Fax: 920.459.5462
Canada Service: 800.695.8560
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>