User Manual
Model: GMC120AP
IMPORTANT NOTES
N.B PLEASE REMOVE THE PLASTIC FROM THE INTERNAL FILTER BEFORE USING THE MACHINE.
Dear Customer
Your new GMC Air Purifier has been manufactured in a state-of-the-art
facility and has passed the strictest quality control procedures. Please read
this manual carefully before using your appliance for the first time and then
please store this manual in a safe place for future reference.
Thank you again for choosing GMC.
If you have any issues at all with your product or any questions then the
quickest route for resolution is to please contact us through our website
www.gmcaircon.co.za or on 012-661-1173.
We will be able to resolve any issues that may arise and our technical team is
always on hand for assistance. We pride ourselves on 100% customer
satisfaction and we trust you will enjoy your new product.
IMPORTANT! PLEASE REMOVE THE PLASTIC FROM THE INTERNAL FILTER BEFORE USING THE AIR PURIFIER.
Safety instructions
- Check the voltage of 100-240V~ 50-60Hz before use.
- Check the power supply unit and the power cable before plugging them in.
- When not in use, unplug the AC adapter from the wall outlet.
- Do not insert any objects into the air inlets and outlets of the unit. It may cause a short circuit. Special care must be taken when operating the device within the reach of children.
- Use the mains and/or power switch to switch the unit “on and off”.
- Never use the power supply unit/line to switch the unit “on and off”.
- Before changing the device, switch it off and unplug the power supply unit from the socket.
- Never attempt to clean the air inlets or outlets with sharp objects.
- Never immerse the appliance in water.
- Never spray flammable liquids into the device.
- Never operate the appliance in a damp room (e.g. bathroom). Risk of electric shock or power transfer.
- Never use hairsprays, thinners or flammable gases in the vicinity of the device, as there is a risk of fire and explosion.
- If candles or gas ovens burn in the same room during operation, open the window occasionally.
- Never cover the air inlet or outlet and keep away any moving textiles that may block the air inlet or outlet. This can damage/destroy the blower motor.
- When handling the appliance, make sure that your hair or clothing does not get into the air outlet. These could be detected by the fan wheel.
- Always position the device on a flat, horizontal and dry surface.
- Never operate the device near heat sources such as heaters, open fires or direct sunlight. The plastic parts can be deformed.
- The unit does not serve as a fan replacement. This considerably shortens the service life of the filter.
- The device must not be used in an environment containing high levels of dust or chlorine.
- Do not place heavy objects on the unit and keep it out of the reach of children.
- The device must not be used in closed, narrow or excessively warm rooms.
- Make sure that the mains cable is not pinched, excessively bent or twisted, as otherwise the cable wire can be exposed and/or damaged.
- If the mains cable is damaged, stop operation and replace it immediately.
- Only use the power supply included in the scope of delivery. Do not use a power supply unit from another device.
- Do not use the included power supply for other devices.
- If the device is defective, switch off the mains switch and disconnect it.
- To avoid interference, do not operate the equipment near microwaves or television sets.
- The device may only be operated by persons who are physically and mentally capable of correct operation in accordance with these operating instructions, or who have been instructed on this device by a responsible person.
- Never switch the appliance on or off with wet hands.
- Do not attempt to repair or make any other adjustments, both electrical and mechanical, to the unit yourself.
- Do not let children play with the packaging, such as plastic films.
- Ensure a minimum distance of 20 cm between the unit and the nearest wall.
Components
- Air outlet
- Ring
- Housing
- Air inlet
- DC socket
- Bottom plate
- Filter
- Base
- Power adapter
Packing list
INSTALLATION
- Invert the equipment after unpacking it.
- Rotate the base cover to take out the filter by the guide arrow.
- Install the filter after opening the package. Rotate the base cover in revert direction described as step 2.
- Plug on with the power adapter.
Take out the transparent packaging bag| Turn the bottom cover counterclockwise
and
take out the filter| Remove the packaging bag of the filter and put the filter
back according to the direction
Install the bottom cover clockwise| Place the product on a flat surface,
insert the adapter and connect the
power supply
OPERATIONS
Control Panel
- Speed display
- PM2.5 display
- Reset
- Timer
- Sleep mode button
- Auto
- Ion
- UV
- Timer button
- Power button
Understanding the air quality light
The color of air quality light corresponds to the ambient air quality.
The brightness of air quality light reflects the current running mode.
Air Quality | PM2.5 | Color indicator |
---|---|---|
Very Good | Oct-60 | Green |
Moderate | 61-150 | Orange |
Bad | 151-300 | Red |
PM2.5
Fine dust is also known as PM2.5. This refers to the size of the dust
particles, half of which at PM2.5 are particles with a diameter of 2.5μm and a
smaller proportion of larger particles and a larger proportion of smaller
particles.
The size of the fine dust is usually less than that of a bacterium and can
therefore not be seen with the naked eye.
MODE | MENU | FUNCTIONAL DESCRIPTION |
---|---|---|
ON/OFF | Press the POWER button to start and stop the unit. The device starts |
working in Auto Mode.
After 10 seconds, the air quality indicator will show the air quality and
automatically and select a suitable speed according to the air quality. The
digital display will show the PM2.5 data.
FILTER RESET| | After running for 2000 hours, the RESET light will be light up
on the display to remind user to replace the filter.
After replacing the fitter, long press the POWER button for 5 seconds to reset
. the life time of filter will restart .
ION UV| | Negative ions and UV are turn on automatically when turn on the
device. Press this button to switch the UV light and Negative Ion on or off.
MANUAL CONTROL/
AUTO MODE| | By repeatedly pressing the Speed button, the fan speed between 1
(low) and 5 (high) and the Auto Mode can be selected.
If you use the unit in AUTO mode, the fan is controlled via the air quality
sensor (PM2.5).
The Auto mode can be left by simply pressing the speed button.
SLEEP MODE| | Pressing the Sleep button to activate the sleep function. This
mode behaves as follows:
•The display illumination including all displays, with the exception of the
Sleep display, is switched off.
•The device switches to the lowest and therefore quietest fan level.
•The LED ambient light is switched off.
•To exit sleep mode, press any key.
TIMER| | With the timer you can set the running time of the device. It can be
selected between 1 and 8 hours by repeatedly pressing the button. If the timer
function is activated, the display shows alternately the PM2.5 value and the
remaining running time. When the time has elapsed, the unit switches itself
off automatically.
Maintenance
Filter change
After some time in operation, the main filter must be replaced. The filter
life is 2000 Hours
Filter change indicator:
The unit is equipped with a modern filter change indicator.
If the filter has to be checked/replaced, this is indicated by the RESET light
flashing on the display.
If the filter has been replaced, the filter change indicator must be reset
again. long press the POWER button for 5 seconds to reset the air purifier.
Change the filter:
Switch and disconnect the device for this purpose. Put it upside down and
open the filter cover at the bottom of the unit and remove the filter.
Please note that the replacement filter must be removed from the protective
film before it can be inserted into the device. Finally, the filter must be
locked again.
Cleaning the device
Always disconnect the power supply from the socket before cleaning!
Clean the appliance with a dry cloth. Do not use chemicals. You can also clean
the air inlets with a vacuum cleaner (it is best to clean the unit outdoors).
Specifications
Product name | Air Purifier | Model | GMC120AP |
---|---|---|---|
Rated voltage/frequency | DC 24V | Product size | 198198330mm |
Power | 20W | Net weight | 1.7kg |
Noise | 23-55dB(A) | Applicable area | 20m2 |
CADR | 120m³/h | Fuselage materials | ABS |
FEATURES
- 120 m³/h clean air rate (CADR)
- 5 Wind Speed Settings.
- 8hr Timer
- 99% virus, allergen & pollutant removal
- 99.5% particle removal
- Air quality display
- Anion
- Auto mode and 5x speed levels
- Ergonomic Touch Button Display
- Filter Usage Display
- H13 Medical Grade HEPA Filter
- High Performance
- Intelligent sensors
- Low energy consumption
- Purifies rooms up to 20 m²
- Sleep Mode
- Smart filter indicator
- Ultra-quiet operation
- Up to 99.9% virus removal
- UV Light
TROUBLE SHOOTING
Phenomenon | Reason & Solution |
---|
The airflow that comes out of the air outlet is significantly weaker than
before.| The surface of the filter is dirty. Clean the surface of the filter
(see the cleaning instructions for filter).
The air quality does not improve, even thoughthe appliance has been operating
for a long time.| •Check if the packing material is removed from the filter.
•Make sure that the filter is properly installed.
•The air quality sensor is dirty or wet. Clean the air quality sensor
•Room size is large or the outdoor air quality is poor. For optimum
purification performance, please close the doors and windows when operating
the air purifier.
•There are indoor pollution resources. For instances, smoking, cooking,
incense.
•Filter reaches the end of life. Replace the filter with a new one.
The appliance produces a strange smell.| Please ensure you have removed the
plastic over the HEPA filter. The first few times you use the appliance, it
may produce a plastic smell. This is normal. However, if the appliance
produces a burnt smell even if removing the filter, contact us at
www.qmcaircon.com or 012-661-1173.
The filter may produce smell after being used for a while because of the
absorption of indoor gases. It’s recommended that you reactivate the filter by
putting it in direct sunlight for repeated use. If odor still exists, replace
the filter.
Three gear indicator lights up at the same time| There is a machine
malfunction. Please cut off the power immediately and contact us on
012-661-1173 orwww.amcaircon.com
El| Please ensure all sensors have been cleaned on the air purifier. If the
problem still persists please contact us on 012-661-1173 or
www.amcaircon.com
The appliance is extra loud.| •Check if the packing of the filter is removed.
•The appliance will run in high speed when the air quality is poor, which will
cause higher noises. When using the appliance in a bedroom at night, choose
the Sleep speed.
•if anything drops into air outlet, it may also cause abnormal loud sounds.
Immediate turn off appliance, turn appliance upside down, to get foreign
objectives out of appliance.
The appliance still indicates that I need to replace a filter, but I already
did.| Perhaps you did not reset the filter lifetime counter. Switch on the
appliance. If the filter has been replaced, the filter change indicator must
be reset again. long press the POWER button for 5 seconds to reset the air
purifier.
SERVICE AND WARRANTY
GMC Airconditioning CC was established in 1995 and is one of South Africa’s
leading cooling and heating companies. We pride ourselves on 100% customer
satisfaction and have the highest online rating of all heating and cooling
companies in South Africa. We will strive to ensure you are 100% satisfied
with your product.
In the rare case of encountering any issues with your product or would like
some support please contact us directly on 012-661-1173 or
www.gmcaircon.co.za as this will allow us to
react quickly to your request. If you have bought this product from one of our
partner platforms, then contacting us directly will allow us to resolve the
issue for you in a timelier fashion.
We are here to help you and ensure you are 100% satisfied.
Please read this instruction manual carefully before setting up or using this
product. If you believe this product to be suffering from a manufacturing
fault, or if you have any inquiries about this product, please contact our
customer support.
CUSTOMER SUPPORT
GMC Airconditioning CC
35 Sarel Baard Crescent
Gateway Industrial Park
Centurion
0046
Telephone: +27 (12) 661-1173
Website: www.gmcaircon.co.za
Email: info@gmcaircon.com
When contacting our customer support, please have the information below
available.
All warranty requests must be accompanied by a proof of purchase, which is a
copy of the original receipt.
Model: ……………………….
Date of purchase: ………………
Purchased from: …………………
For enquiries or support : visit www.gmcaircon.co.za or contact us on 012-661-1173