TECH Sinum FC-S1m Temperature Sensor User Manual

June 1, 2024
TECH

TECH Sinum FC-S1m Temperature Sensor

Product Information

  • Specifications:
    • Model: FC-S1m
    • Power Supply: 24V
    • Max. Power Consumption: Not specified
    • Temperature Measurement Range: Not specified

Product Usage Instructions

  • Sensor Connection:
    • The system has a terminating connection.
    • The position of the sensor on the transmission line with the Sinum Central is determined by the position of the terminating switch 3.
    • Set to ON position (sensor at the end of the line) or position 1 (sensor in the middle of the line).
  • Identifying the Device in the Sinum System:
    • To identify the device in the Sinum Central, follow these steps:
    • Activate the Identification Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab.
    • Hold the registration button on the device for 3-4 seconds.
    • The device used will be highlighted on the screen.

FAQs

  • EU Declaration of Conformity:
    • The product may not be disposed of in household waste containers. Please transfer used equipment to a collection point for proper recycling of electric and electronic components.
  • Contact Information:

Connection

TECH-Sinum-FC-S1m-Temperature-Sensor-fig-1 \(1\)

  • The FC-S1m sensor is a device that measures the temperature and humidity in the room.
  • Additionally, a floor sensor can be connected to the device 4.
  • Sensor measurements are displayed in the Sinum Central device.
  • Each parameter can be used to create automations or assigned to a scene.
  • FC-S1m is flush mounted in a Ø60mm electrical box and communicates with the Sinum Central device via cable.

Sensor connection

  • The system has a terminating connection.
  • The position of the sensor on the transmission line with the Sinum Central is determined by the position of the terminating switch 3.
  • Set to ON position (sensor at the end of the line) or position 1 (sensor in the middle of the line).

How to register the device in the sinus system

  • The device should be connected to the Sinum central device using the SBUS connector 2 and then enter the address of the Sinum central device in the browser and log in to the device.
  • In the main panel, click the Settings > Devices > SBUS devices >+ > Add device.
  • Then briefly press the registration button 1 on the device.
  • After a properly completed registration process, an appropriate message will appear on the screen.
  • Additionally, the user can name the device and assign it to a specific room.

How to identify the device in the Sinum system

  • To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab and hold the registration button on the device for 3-4 seconds.
  • The device used will be highlighted on the screen.

Technical Data

  • Power supply 24V DC ±10%
  • Max. power consumption 0,2W
  • Temperature measurement range – 30 ÷ 50ºC

Notes

  • TECH Controllers is not responsible for any damages resulting from improper use of the system.
  • The manufacturer reserves the right to improve devices and update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look.
  • The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
  • Before using the device for the first time, read the following regulations carefully.
  • Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children.
  • It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.).
  • The device is not water resistant.
  • The product may not be disposed of in household waste containers.
  • The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration Of Conformity

Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122) Hereby, we declare under our sole responsibility that the FC-S1m sensor is compliant with Directive:

  • 2014/35/UE
  • 2014/30/UE
  • 2009/125/WE
  • 2017/2102/UE

For compliance assessment, harmonized standards were used:

  • PN-EN IEC 60730-2-9:2019-06
  • PN-EN 60730-1:2016-10
  • PN-EN IEC 60730-2-13:2018-11
  • PN-EN IEC 62368-1:2020-11
  • EN IEC 63000:2019-01 RoHS
  • Wieprz, 01.12.2023

The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

TECH User Manuals

Related Manuals