According the “Quick Installation Guide Industrial Ethernet Switch.pdf”, page7:
Device Reset:
- Press and hold the reset button for 6 to 10 seconds. All the LEDs on the DIS-200G will light amber. When this happens, release the reset button and the DIS-200G will be reset to factory defaults.
Note: holding the reset button for more than 11 seconds will cause all LEDs on the DIS-200G to light green. Holding the reset button for a further 2 seconds will put the DIS-200G into boot loader mode.
Based on my test there is no problem with F/W 1.00.043, 1.10.023, 1.10.024,
and 1.20.006.
This is my test step:
Reboot:
-
Login console by [admin/admin] and add new account [test/12345678].
Switch# conf t
Switch(config)# username test password test
Switch(config)# exit
Switch# copy running-config startup-config -
Re-login console by “test/test”.
Switch>
-
Holding reset button for more than 11 seconds, the LEDs are light green, and the DUT is rebooting.
-
Re-login console by “test/test”, it is able to login.
Reset Default:
-
Login console by [admin/admin] and add new account [test/12345678].
Switch# conf t
Switch(config)# username test password test
Switch(config)# exit
Switch# copy running-config startup-config -
Re-login console by “test/test”.
Switch>
-
Press and hold the reset button for 6 seconds, and then release the reset button,
the LEDs are light amber, and it shows “The configuration is resetting to Factory
Default” on the console message.Switch>
The configuration is resetting to Factory DefaultSave configuration
-
Re-login console by “test/test”, it cannot login. And the DUT is default.