YHDC SCT010T Split Core Current Transformer Instruction Manual

May 15, 2024
YHDC

YHDC logoSCT010T

SCT010T Split Core Current Transformer

Ф10mmAperture Split core current transformer

YHDC SCT010T Split Core Current Transformer

Characteristic

  • Safety lock buckle, easy to install
  • Built-in over-voltage protection device (TVS tube)
  • Crimping terminal output
  • Suspended type

Product application

  • Portable instrument
  • Household metering
  • Monitor motor load

Product advantage

  • Small volume,light weight
  • Low cost
  • High turns,high precision

Installation diagram

Primary threading method(Firing line)

  1. Open the buckle
  2. Open upward
  3. Put in lead wire
  4. Fasten the buckle

Typical technical index:

  • Material of core — Ferrite
  • Working voltage — Phase voltage≤720V
  • Working temperature — 25℃~+60℃
  • Storage temperatureb b— 30℃~+90℃
  • Frequency range — 50Hz~1KHz
  • Dielectric strength — Input( bare conductor)/output AC 800V/1min 5mA 50Hz
    Output/Outer shell AC 3.5KV/1min 5mA 50Hz

Electrical parameters:( The following parameters are typical values and actual values will be subject to product testing)
Max. continuous input current: 120% of rated input

Model| Input current| Output| Turns ratio| Load resistance| Accuracy| Linearity| Weight
---|---|---|---|---|---|---|---
SCT010T| 20A| 20mA| 1:1000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 20A| 5mA| 1:4000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 50A| 50mA| 0.388888889| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 50A| 16.6mA| 1:1000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 60A| 20mA| 1:3000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 80A| 80mA| 1:3000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 80A| 40mA| 1:1000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 80A| 26.6mA| 1:2000| 10Ω| 0.5%/1%| 1%| 45g
SCT010T| 50A| 0.1A| 1:3000| 10Ω| 0.5%/1%| 1%| 45g
Model| Input current| Output| Turns ratio| Load resistance| Accuracy| Linearity| Weight
---|---|---|---|---|---|---|---
SCT010T| 10A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g
SCT010T| 20A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g
SCT010T| 30A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g
SCT010T| 50A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g
SCT010T| 60A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g
SCT010T| 80A| 0.333V| –| built-in| 0.5%/1%| 1%| 45g

  • Can be customized parameters/lead length/lead specifications according to user requirements.

Wiring schematic diagram:

Built-in sampling resistance Voltage output type, Secondary doesn’t allow short circuit TVS:Transient voltage suppressor Current output type, Secondary doesn’t allow open circuit
Outline size: (in:mm):YHDC SCT010T Split Core Current Transformer - diagram
2

YHDC logo www.poweruc.pl

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>