phrozen CURE BEAM Post Curing UV Light String User Manual
- June 1, 2024
- phrozen
Table of Contents
phrozen CURE BEAM Post Curing UV Light String
Product Specifications
- Power Requirement: DC 7.5V 1A
- Wavelength: 700mA
- LED Specifications : 405nm
- Controller Power : 5W
Product Usage Instructions
Step-by-Step Instructions
When the device is turned on manually, the red indicator light will be turned on as well. The UV light will then be on continuously until the device has been turned off. If the UV light hasn’t been used for 60 minutes, the device will automatically turnoff.
Button Functionality
- POWER: Click on the Power button to turn on (or turn off) the device.
- TIMER H. S: The indicator light from the Timer H.S button will light up in red once the device is turned on.
- TIMER 1 MIN : The UV light will automatically turn off after 1 minute when the yellow indicator light is turned on.
- TIMER 10 MIN : The UV light will automatically turn off after 10 minutes when the green indicator light is turned on.
Warnings
DO NOT stare directly at the UV light. Please wear safety glasses before usage. DO NOT touch or poke the UV light source with sharp objects. Do not use electric cords from other devices. Do not use any chemicals to rub the lens of the UV light device. Do not use it with other adaptors.
Alcohol Cleaning: Use sanitizing alcohol to clean the exterior of the device. Do not use any oily or corrosive liquids to clean the device.
Connectors
- CH1: This is the CH1 electric power connector.
- CH2: This is the CH2 electric power connector.
FAQ
- Can I use this device with adaptors other than the specified one?
- No, please do not use any other adaptors with this device. Use only the included power cord set packaged with the main unit.
- How should I clean the device?
- Use sanitizing alcohol to clean the exterior of the device. Avoid using oily or corrosive liquids for cleaning.
Product Specifications
- Power Requirement: DC 7.5V;1A
- Wavelength: 700 mA
- LED Specifications : 405 nm
- Controller Power :” 5 W
Instructions
Step-by-Step Instructions
Button Functionality
When the device is turned on manually, the red indicator light will be turned on as well. The UV light will then be on continuously until the device has been turned off. If the UV light hasn’t been used for 60 minutes, the device will automatically turn off.
Click on the Power button to turn on (or turn off) the device. Once the device has been turned on, the indicator light from the Timer H.S button will light up in red. Click on the Power button one more time to turn off the device.
When the yellow indicator light is turned on, the UV light will automatically turn off after 1 minute.
When the green indicator light is turned on, the UV light will automatically turn off after 10 minutes.
When the green indicator light is turned on, the UV light will automatically turn off after 10 minutes.
This is the CH1 electric power connector.
Warning
- DO NOT stare directly at the UV light. Please wear safety glasses before usage.
- DO NOT touch or poke the UV light source with sharp objects.
- Please do not use electric cords from other devices.
- Do not use any chemicals to rub the lens of the UV light device.
- Do not use it with other adaptors.
- The included power cord set packaged with the main unit cannot be used with electrical equipment other than the specified device
Maintenance: Please use sanitizing alcohol to clean the exterior of the device. Do not use any oily or corrosive liquids to clean the device.
Please follow Phrozen’s social media accounts and subscribe to our YouTube channel to learn more about printing tips and share ideas with one another. Feel free to contact us if you have any question