SIEMENS RF600 Excerpt Syh Simatic Instruction Manual
- June 1, 2024
- SIEMENS
Table of Contents
SIEMENS RF600 Excerpt Syh Simatic
Note: This document is a draft document. This document is not released for publication. Siemens accepts no liability for the completeness or correctness of the contents.
Legal information
Warning notice system
This manual contains notices you have to observe to ensure your safety, as
well as to prevent property damage. The notices referring to your safety are
highlighted in the manual by a safety alert symbol, notices referring only to
property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper
precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper
precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not
taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified for the specific task in accordance with the relevant
documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are
capable of identifying risks and avoiding potential hazards when working with
these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the
catalog and in the relevant technical documentation. If products and
components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly,
commissioning, operation and maintenance are required to ensure that the
products operate safely and without any problems. The permissible ambient
conditions must be complied with. The information in the relevant
documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The
remaining trademarks in this publication may be trademarks whose use by third
parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with
the hardware and software described. Since variance cannot be precluded
entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are
included in subsequent editions.
Characteristics
The SIMATIC RF695R is a stationary reader in the UHF frequency range without an integrated antenna. Up to eight external UHF RFID antennas can be connected via RP-TNC connectors. The maximum transmit power is 2000 mW at the reader output. A radiated power of up to 2000 mW ERP / 4000 mW EIRP is achieved when the appropriate antennas and antenna cables are used. The interfaces (Ethernet, power supply, DI/DQ interface) are located on the lower front edge. These interfaces can be used to connect the reader to the power supply and to a PC or a controller for parameter assignment. The degree of protection is IP65.
Pos. | Description |
---|
| ①| RP- TNC interfaces
for connecting up to 8 external antennas
②| LED operating display
③| Power supply interface (NEC Class 2): X80
(terminal block)
④| DI/DQ interface: X10
(terminal block)
⑤| CLP interface (Configuration license
plug): CLP
⑥| Ethernet interface: X1 LAN
(RJ45)
⑦| Protective Earthing (PE) connection
⑧| Reset button: RESET
Ordering data
Table 1- 1 RF695R ordering data
Product | Article number |
---|---|
RF695R (ETSI) | 6GT2811-7DD20-0AA0 |
RF695R (FCC) | 6GT2811-7DD20-1AA0 |
RF695R (CMIIT) | 6GT2811-7DD20-2AA0 |
Table 1- 2 Ordering data accessories
Product | Article number |
---|---|
SIMATIC RF600 antenna holder 3-way kit | 6GT2890-2AB10 |
Connecting cable and connectors | |
• DI/DQ cable connector open cable ends | |
• Ethernet plug on the reader FastConnect M12 (IP65) | |
• Ethernet plug Standard IE FastConnect RJ45 180 (IP20) |
6GK1901-1BB10-2AA0
| • Industrial Ethernet cable M12 / RJ45| 5 m| 6XV1871-5TH50
| • Industrial Ethernet cable M12 / M12| 5 m| 6XV1870-8AH50
| • Industrial Ethernet connecting cable M12-180 / RJ45| 2 m| 6XV1871-5TH20
3 m| 6XV1871-5TH30
5 m| 6XV1871-5TH50
| • Industrial Ethernet cable
by the meter, green (minimum 20 m)
| 6XV1840-2AH10
| • Connecting cable reader ↔ CM M12-180 / M12-180| 2 m| 6GT2891-4FH20
5 m| 6GT2891-4FH50
10 m| 6GT2891-4FN10
20 m| 6GT2891-4FN20
50 m| 6GT2891-4FN50
Connecting cable CM ↔ reader / extension cable for 24 V connecting cable
RS422, M12 connector, 8-pin socket
| • 2 m| 6GT2891-4FH20
| • 5 m| 6GT2891-4FH50
| • 10 m| 6GT2891-4FN10
| • 20 m| 6GT2891-4FN20
| • 50 m| 6GT2891-4FN50
Wide-range power supply unit for SIMATIC RF systems
| • With EU plug| 6GT2898-0AC00
| • With UK plug| 6GT2898-0AC10
| • With US plug| 6GT2898-0AC20
Product| Article number
---|---
24 V connecting cable reader ↔ wide-range power supply unit
| • with plug, 5 m| 6GT2891-0PH50
| • with open ends, 2 m| 6GT2891-4EH20
| • with open ends, 5 m| 6GT2891-4EH50
Set of protective caps
Contains 3 protective caps for antenna output, one protective cap for digital I/O interface and 2 protective caps for Ethernet/PROFINET (required for IP65 degree of
protection when some connectors are unused)
| 6GT2898-4AA10
Pin assignment
Pin assignment of the power supply interface (X80)
Table 1- 3 Pin assignment of the power supply interface (reader side)
Interface view | Pin | Assignment |
---|---|---|
1 | L2+ | + 24 V load supply |
2 | M2- | Ground of load supply |
3 | L1+ | + 24 V module/encoder supply |
4 | M1 | Ground of module/encoder supply |
Note
Requirement for external power sources
The reader must only be supplied with power by power supply units that meet
the requirements of LPS (Limited Power Source) and NEC Class 2. Requirement
for external power sources The reader must only be supplied with power by
power supply units that meet the requirementsof limited power source (LPS) and
NEC Class 2.
Notes on connectors and cables
NOTICE
Insulate unused single wires
Unused single wires must be insulated individually to prevent unwanted
connections of signal lines.
NOTICE
For long cables : Adapt the power supply and transmission speed
Note that even with long cables, the supply voltage of 24 VDC must always be
guaranteed. Note also that the transmission speed on the serial interface
must, if necessary, be reduced. SIMATIC standard cables (e.g. 6GT2891-4FN10)
have a loop resistance of 160 mOhm / meter. This results in a voltage drop of
0.8 volts on the 24 V cable for every 10 meters of connecting cable and with a
power requirement of 500 mA. If the power requirement increases through the
use of the digital inputs/outputs, the voltage drop increases accordingly.
Pin assignment of DI/DQ interface (X10)
Table 1- 4 Pin assignment of the DI/DQ interface (reader end)
Interface view | Pin | Pin assignment |
---|---|---|
Digital input/output (3 pins) | ||
1 | 1Us | Ground of module/encoder supply |
2 | 1M | Voltage output, galvanically connected |
3 | DIQ | Digital input/output |
Digital input/output or IO-Link (3 pins)
4| 1Us| Voltage output (L1+), galvanically connected
5| 1M| Voltage output (M1), galvanically connected
6| C/Q| Digital input/output or IO-Link
Power supply IO-Link class B (2 pins)
7| 2UA| Infeed of load supply (L2+), galvanically
isolated from L1+
8| 2M| Load supply, galvanically isolated
Note Requirement for external power sources
When the DI/DQ interface is supplied with power by an external power source,
this source must meet the requirements for LPS (Limited Power Sources) and NEC
Class 2.
Protective earthing connection
On the bottom of the reader, there is a blind drill hole (M4 x 8) for
protective earthing. Tighten the screw with a torque of ≃ 1.5 Nm.
WARNING
Hazardous voltage due to lightning strikes
Death or serious injury may occur as a result of lightning strikes to antennas mounted outside buildings. If the reader is operated with antennas mounted outside buildings, the reader must be reliably connected to the protective earthing connection.
NOTICE
Installation only in protected areas
The antenna can be installed in the protected part of a building. When
implementing your lightning protection concept, make sure you adhere to the
VDE 0182 or IEC 62305 standards.
Protective earthing connection
| ①| Screw (M4 x 8)
②| Flat washer
③| Cable lug
④| Contact washer
⑤| Minimum wire diameter > 1 mm2 (AWG 18)
Planning operation
Antenna/reading point configurations
You can connect up to eight external antennas to the RF695R reader. The
standard setting is that an antenna is connected when the reader is started.
When connecting multiple antennas, note the information in the section
“AUTOHOTSPOT”. With the WBM, you can set up various different configurations
of antennas and/or reading points as required. Based on the number of data
sources and subsequent assignment of the antennas, many tasks can be
accomplished.
Examples of possible antenna reading point configurations
- Eight data sources with one antenna each for eight different reading points.
- Four data sources with two antennas each for small portals.
- One data source with 4 to 8 antennas for large portals. You will find further information in the online help of the products.
Mounting
Requirement
NOTICE
Close unused connectors Note that the readers only have the specified
degree of protection when all connectors are in use or when unused connectors
are closed with the protective caps. Close any connectors on the reader that
you are not using with protective caps. You can order the protective cap set
using the article number specified in the section “Ordering data”.
CAUTION
Radiation load
The transmitter complies with the requirements of Health Canada and the FCC
limit values for subjecting persons to HF radiation, provided that a minimum
spacing of 20 cm exists between antenna and person. When the antennas are
installed, you must therefore ensure that a minimum spacing of 20 cm is
maintained between personnel and antennas.
Mounting options
The following mounting systems/holders are available for securing the readers:
- Mounting on a T35 DIN rail (S7-1200)
- SIMATIC RF600 antenna holder 3-way kit via a standardized VESA 100 mounting system (4 x M4, torque ≃ 1.5 Nm)
- VESA 100 mounting system (4 x M4, torque ≃ 1.5 Nm)
For detailed information on the mounting systems/holders and on mounting the readers, refer to the section “Reader and antenna holders “. The positions of the mounting holes are shown in the section “Dimension drawing “.
Technical specifications
Table 1- 5 Technical specifications of the RF695R reader
- Measured at the output of the antenna socket.
- All supply and signal voltages must be safety extra low voltage (SELV/PELV according to EN 60950 or EN 62368). All voltage sources must meet the requirements of limited power sources (LPS) and NEC Class 2. Note that, depending on the power consumption, using extension cables > 20 m (6GT2891-4FN50) may lead to a voltage drop on the reader. This voltage drop can mean that the necessary minimum voltage on the reader is below the required 20 V.
- The values for shock and vibration are maximum values and must not be applied continuously. These values only apply to mounting using screws.
Dimension drawing
@@@ Dimension drawing @@@ Dimension drawing of SIMATIC RF695R All dimensions in mm (± 0.5 mm tolerance)
Certificates & approvals
Note Marking on the readers according to specific approval
The certificates and approvals listed here apply only if the corresponding
mark is found on the readers.
Table 1- 6 6GT2811-7DD20-0AA0
For information on which reader variant can be used in which country or region, refer to the “List of country profiles”.
Table 1- 7 6GT2811-7DD20-1AA0
Table 1- 8 6GT2811-7DD20-2AA0
Standard|
---|---
CMIIT Certification| China radio approval
Marking on the reader: CMIIT ID: 2014DJ3989
FCC information
Siemens SIMATIC RF695R (FCC): 6GT2811-7DD20-1AA0
FCC ID : NXW-RF600R2 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
FCC Notice
To comply with FCC part 15 rules in the United States, the system must be
professionally installed to ensure compliance with the Part 15 certification.
It is the responsibility of the operator and professional installer to ensure
that only certified systems are deployed in the United States. The use of the
system in any other combination (such as co-located antennas transmitting the
same information) is expressly forbidden.
FCC Exposure Information
To comply with FCC RF exposure compliance requirements, the antennas used for
this transmitter must be installed to provide a separation distance of at
least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter.
IC-FCB information
Siemens SIMATIC RF685R (FCC): 6GT2811-7DD20-1AA0
IC: 267X-RF600R2
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
In order to comply with ISED RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times To comply with Industry Canada licence-exempt RSS standard(s), the system must be professionally installed to ensure compliance with IC certification.
Industry Canada Notice
To reduce potential radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that permitted for successful communication.
Transmitter power and antenna information for antennas with a gain less than 6
dBi: This device has been designed to operate with the SIMATIC RF615A antenna
902-928, the SIMATIC RF620A antenna 902-928, the SIMATIC RF622A antenna
902-928, the SIMATIC RF650A antenna 902-928, the SIMATIC RF680A antenna
902-928 as well as the SIMATIC RF660A antenna 902-928 listed below, and having
a maximum gain of 5,5 dBi. Arbitrary transmission power settings in
combination with other antennas or antennas having a gain greater than 5,5 dBi
are strictly prohibited for use with this device. The required antenna
impedance is 50 Ohms.
Transmitter power and antenna information for antennas with a gain greater
6 dBi:
This device requires professional installation. Antennas with a gain greater 6
dBi may be used provided the system does not exceed the radiation power of
4000 mW E.I.R.P. This device has been designed to operate with the SIMATIC
RF642A antenna 902-928 exceeding the maximum gain of 5,5 dBi under the
restriction that the RF power at the input of the antenna must be set to meet
the following relation: RF power (dBm) ≤ 30 dBm – (antenna gain (dBi) – 6 dBi)
Other antennas or system configurations for antennas having a gain greater
than 6 dBi are strictly prohibited for use with this device. The required
antenna impedance is 50 Ohms.
Reader and antenna holders
Depending on the device used, the following mounting systems/holders are available to you to mount the respective readers and antennas:
SIMATIC RF600 antenna holder 3-way kit
The following readers and antennas have a standardized VESA 100 mounting
system (4 x M4) and can be fixed to the antenna holder with this:
- SIMATIC RF610R, RF615R, RF650R, RF680R, RF685R, RF690R, RF695R
- SIMATIC RF642A, RF650A, RF660A, RF662A, RF680A
SIMATIC RF600 aluminum holding plate
The following readers and antennas, for example, can be mounted on a pedestal
or in a frame using the holding plate:
- SIMATIC RF610R, RF615R
- SIMATIC RF615A, RF622A
Mounting kit for DIN/mounting rail
The SIMATIC RF650R, RF680R, and RF685R readers can be mounted on one of the
following DIN rails or mounting rails using an adapter kit:
- DIN rail T35 (S7-1200)
- S7-300 mounting rail
- S7-1500 mounting rail
The SIMATIC RF690R, and RF695R readers can be mounted directly on a T35 DIN rail (S7-1200) without the use of an adapter kit.
Antenna holder 3-way kit
Ordering data
Table 2- 1 Order data of SIMATIC RF600 antenna holder 3-way kit
Description | Article number |
---|
SIMATIC RF600 antenna holder 3-way kit (stainless steel)
for mounting readers and antennas
| 6GT2890-2AB10
Mounting with the antenna holder
Flexible mounting is possible with the antenna holder. The RF600 readers/antennas can be rotated in any direction with this holder. Follow the steps below to mount the antenna holder with the reader or the antenna on the wall:
- Install the wall mounting plate (A) on the wall.
- Install the articulated joint (B) with the screws ① on the wall mounting plate (A).
- Fasten the reader or the antenna using the four bore holes on the antenna mounting plate (C).
- Mount the antenna mounting plate (C) into the articulated joint (B) and fasten it with the help of screws ② to the articulated joint (B).
- Align the antenna holder by sliding the setting angle on the articulated joint (B) and tighten all the screws.
Technical specifications
Table 2- 2 Technical specifications
Dimension drawing
Aluminum holding plate
Order data
Table 2- 3 Order data for SIMATIC RF600 aluminum holding plate
Description | Article number |
---|
SIMATIC RF600 aluminium holding plate
for mounting readers and antennas
| 6GT2890-2AC00
Technical specifications
Table 2- 4 Technical specifications
Dimension drawing
- ∅ 7 mm (6x) for attachment to a pedestal
- ∅ 5 mm (4x) for attaching the RF610R and RF615R readers to the holding plate
- ∅ 6 mm (4x) for attaching the RF622A antenna to the holding plate
- ∅ 5 mm (4x) for attaching the RF615A antenna to the holding plate
All dimensions in mm (tolerances according to DIN ISO 2768 – medium).
Mounting kit for DIN/mounting rail
Order data
Table 2- 5 Ordering data of mounting kit for DIN/mounting rail
Description | Article number |
---|
Mounting kit for DIN/mounting rail
• DIN rail T35 (S7-1200)
• S7-300 mounting rail
• S7-1500 mounting rail
| 6GT2890-0AB00
Securing onto a DIN/mounting rail
Installation on a DIN rail SIMATIC RF650R/RF680R/RF685R
Follow these steps to mount the SIMATIC RF650R, RF680R or RF685R readers on
a DIN rail using the mounting kit:
Table 2- 6 DIN rail mounting
Description | |
---|---|
1. | Place the spring in the groove. |
2. | Insert the holder. Make sure that the angled tip is |
positioned above the spring in the groove.
3.| Mount the holder using the supplied Torx screws.
| Description
---|---
| 4.| Fit the lower locking mechanism of the reader
onto the top edge of the DIN rail ①.
5.| Pull down the holder mounted in step 2 ② while pressing the reader backwards at the bottom ③ at
the same time.
6.| Release the holder mounted in step 2 ②.
Make sure that the holder locks into the DIN rail and the reader sits securely on the DIN rail.
SIMATIC RF690R/RF695R
The mounting of the SIMATIC RF690R and RF695R readers is very similar to the
mounting of the SIMATIC RF650R, RF680R and RF685R readers, except that the
RF690R/RF695R readers only have one locking mechanism and the holder for
hanging in a DIN rail is already premounted.
To mount the RF690R/RF695R readers on a T35 DIN rail, use steps 4 to 6 of the
previous instructions for mounting the RF650R/RF680R/RF685R readers on a DIN
rail as a guide.
Installation on a mounting rail
- Follow these steps to mount the SIMATIC RF650R, RF680R or RF685R readers on a mounting rail using the mounting kit:
Table 2- 7 Installation on a mounting rail
Description | |
---|---|
1. | Mount the two adapter pieces using the supplied Torx countersunk head |
screws ①.
| 2.| Fit the upper locking mechanism of the reader into
the top edge of the DIN rail ②.
3.| Secure the reader using the supplied slotted-head screws ③.
Auszug aus dem SYH “SIMATIC RF600” Operating Instructions, 04/2023, C79000-G8976-C6xx-01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>