Altronix NetWay1 Single Port PoE Injector for Standard NetWork Infrastructure Installation Guide
- June 4, 2024
- Altronix
Table of Contents
- Overview:
- Features:
- CAT-5 Structured Cable Wiring Color Codes and PIN Configuration
- Installation Instructions:
- NetWay1:
- NetWay1X:
- NetWay1 Port Status and LED Flash Codes
- NetWay1 Port Status and LED Flash Codes
- Typical Applications (NetWay1 and NetWay1X):
- Maintenance:
- Troubleshooting:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NetWay1 Single Port PoE Injector for Standard Network Infrastructure
Installation Guide
Overview:
Altronix NetWay1 and NetWay1X are single port PoE/PoE+ injectors that provide
power and pass data (e.g. video) for PoE/PoE+ compliant devices. Devices may
be located up to 100m from NetWay1/NetWay1X.
To extend data distance for an additional 100m use NetWayXT/NetWayXTX repeater
modules.
Features:
Agency Listings:
NetWay1:
• UL:|
---|---
UL294*| Access Control Systems
UL294B| Power over Ethernet (PoE) for
Access Control
• UL/cUL:|
UL 60950-1| Information Technology
Equipment.
• cUL:|
CSA Standard C22.2
No.205-M1983| Signal Equipment
• CE European Conformity.
NetWay1X:|
• UL/cUL:|
UL 60950-1| Information Technology Equipment.
• CE European Conformity.
Input:
- NetWay1: 24VAC @ 1.2A or 24VDC @ 1.2A.
- NetWay1X: 24VAC @ 1.5A or 24VDC @ 1.5A.
PoE/PoE+:
- NetWay1: IEEE 802.3af (15W) compliant.
- NetWay1X : IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
Features:
-
Port status LED.
-
PoE manual shutdown (For UL 60950-1 application only)
(see Technical Specifications table pg. 4). -
Auto detection and protection of legacy non-PoE cameras/devices.
-
Data rate: 10/100 BASE-T compliant.
-
Compact insulated housing.
Dimensions (W x L x H approx.):
NetWay1:
2.5” x 3.8” x 1” (63.5mm x 96.5mm x 25.4mm).
NetWay1X:
3.5” x 3.5” x 1” (88.9mm x 88.9mm x 25.4mm).
* ANSI/UL 294 7th Ed. Access Control Performance Levels:
Destructive Attack – I; Endurance – N/A; Line Security – I; Stand-by Power –
II.
Compliance with IEEE 802.3 (at or af) specifications was not verified as part
of these requirements. Equipment is intended to comply with the following
sections of the National Electrical Code, ANSI/NFPA 70:Article725.121. Not
suitable for connection to outside wiring. Article 800 in the National
Electrical Code, NFPA 70. Category 5e cabling is the minimum performance
category recommended. The performance category utilized should match the
transmission speed required at the installation site. The minimum conductor
gauge permitted to connect between the PSE or power injector and the PD shall
be 26AWG (0.13 mm2 ) for patch cords; 24AWG (0.21 mm2 ) for horizontal or
riser cable. Products that utilize power over communications cable are
typically connected through standard eight-pin RJ45 connectors. This power
sourcing equipment (PSE) uses Mode B for power/data transfer. Please see the
connector configuration diagram (see below).
The maximum power class supported by the PSE is 802.3af class levels 1-3.
CAT-5 Structured Cable Wiring Color Codes and PIN Configuration
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction. Wiring
should be UL Listed and/or Recognized wire suitable for the application.
The unit is intended to be used with a UL Listed Class 2 or LPS (limited power
supply). NetWay1/NetWay1X is not intended to be connected to outside plant
leads and should be installed indoors within the protected premises.
NetWay1/NetWay1X is intended for indoor use only.
1. Mount NetWay1/NetWay1X in the desired location utilizing the mounting hole
(Figs. 1a and 2a, pg. 2). Use a proper fastener and/or wall anchor when
securing NetWay1/NetWay1X with a screw through its mounting hole to the wall.
2. Connect 24VAC/24VDC to terminals marked [24VAC/VDC Input] (Figs. 1b and
2b, pg. 2). Use 22AWG-16AWG wire for this connection. Input power should be a
UL Listed Access Control power-limited power supply (for UL294 applications)
or Class 2 rated transformer/power supply (for UL60950-1 applications).
3. Connect the structured cable from port marked [IN] on NetWay1/NetWay1X to
the corresponding input of a UL Listed ethernet switch or video server (Figs.
1b, 2b, pg. 2).
4. Connect the structured cable from the port marked [OUT] on the
NetWay1/NetWay1X to the PoE device (Figs. 1b, 2b, pg. 2).
All interconnected devices must be UL Listed.
5. Port status LED will illuminate indicating normal operation (Figs. 1c, 2b,
pg. 2).
6. To initiate PoE shutdown connect 12VAC to 24VAC or 5VDC to 24VDC to the
input terminals marked [PoE Shutdown] on the NetWay1/NetWay1X (Figs. 1b, 2b,
pg. 2). The PoE output voltage may be shut down by manually applying voltage
in the rated range (PoE Shutdown Voltage Range in Specifications). Upon
applying voltage the output will drop to zero volts. Removal of voltage from
the shutdown terminals or applying zero volts to the shutdown terminals will
allow the PoE output to operate normally to supply power to PoE-compliant
devices.
Note: Return to normal operation from shutdown can take about 4 seconds.
Although there is no output voltage to power PoE devices during the shutdown,
data signals may still be present on the data pair lines of the CAT5e cable.
NetWay1:
NetWay1X:
NetWay1 Port Status and LED Flash Codes
Port Status | Flash Code | Flash Pattern |
---|---|---|
Non-Powered Device On < RPORT < 2000 | OFF | LED OFF |
Port Open RPORT > 1 MO | OFF | LED OFF |
Port On 25k0 | ON | LED ON |
Low Signature Resistance
3000 < RPORT < 15k0| 1 Flash|
High SignAture Resistance 33K0 < FIPORT < 500k0| 2 Flashes|
Port Overload Fault| 5 Flashes|
NetWay1 Port Status and LED Flash Codes
Port Status | Flash Code | Flash Pattern |
---|---|---|
The Port is not powered or disconnected | OFF | LED OFF |
Port is connected to a valid PD and powered | ON | LED ON |
Overcurrent fault during port power-on | 2 Flashes | ![Altronix NetWay1 Single |
Port PoE Injector for Standard NetWork Infrastructure - Icon
4](https://manuals.plus/wp-content/uploads/2022/08/Altronix-NetWay1-Single-
Port-PoE-Injector-for-Standard-NetWork-Infrastructure-Icon-4.jpg)
Invalid low or high discovery signature resistance| 5 Flashes|
Typical Applications (NetWay1 and NetWay1X):
Maintenance:
The unit should be tested at least once a year for the proper operation as
follows:
While the NetWay1/NetWay1X is powered and the output is connected to a
suitable UL Listed PoE device, it should be tested for PoE shutdown operation
(For UL 60950-1 application only).
For UL294 applications, the NetWay1 is to be tested as part of a complete
Access Control System and in accordance with listed Access Control Devices.
Troubleshooting:
Refer to NetWay1/NetWay1X Port Status and LED Flash Codes, pgs. 2 and 3.
Parameter | Description |
---|---|
No. of Ports | One (1) |
Input power requirements | NetWayl: 24VAC @ 1.2A or 24VDC @ 1.2A. |
NetWay1X: 24VAC @ 1.5A or 24VDC @ 1.5A.
Indicators| Port Status LED, Power In LED (NetWay1X only).
PoE Shutdown Voltage and
Current Range| 5VDC to 24VDC or 12VAC to 24VAC
Maximum current: 2mA for 5VDC
Maximum current for higher voltages: 10mA Class 2 Power-Limited.
Environmental Conditions| Operating Ambient Temperature:
NetWayl : UL60950-1: 0°C to 40°C (32°F to 104°F).
UL294: 0°C to 49°C (32°F to 120.2°F).
NetWayl X: 48VDC, 30W: 0°C to 45°C (32°F to 113°F).
24VAC, 30W: 0°C to 37°C (32°F to 98.6°F).
Relative humidity: 85%, +/— 5%.
Storage Temperature: — 20°C to 70°C (— 4°F to 158°F).
Operating Altitude: — 304.8 to 3,048m.
Regulatory Compliance|
UL/cUL Listed for Information Technology Equipment (UL 60950-1).
UL Listed for Access Control Systems (UL294 – NetWayl only).
Power over Ethernet (PoE) for Access Control (UL294B – NetWayl only).
cUL Listed – GSA Standard C22.2 No.205-M1983, Signal Equipment (NetWayl only).
CE European Conformity.
Weights (approx.)| NetWayl: Product: 0.2 lb. (0.09 kg) I Shipping: 0.25
lb. (0.11 kg)
NetWay1X: Product: 0.25 lb. (0.11 kg) I Shipping: 0.3 lb. (0.14 kg)
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA |
718-567-8181 | fax:
718-567-9056
website: www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty
NetWay1 / NetWay1X Rev. 051619
H19U
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>