ProTeam GoFitTM6 HEPA Media Vacuum Unit Instruction Manual

June 1, 2024
ProTeam

ProTeam logo Instruction Manual

GETTING STARTED

This quick start guide has basic information for the use and safe operation of this machine. However, the owner’s manual has important, detailed information.
Carefully read both before using your new ProTeam vacuum.
CARTON CONTENTS:ProTeam GoFitTM6 HEPA Media Vacuum Unit - CARTON
CONTENTS

QUICK START INSTRUCTIONS:ProTeam GoFitTM6 HEPA Media Vacuum Unit -
INSTRUCTIONS PREPARING BATTERY PACK FOR CHARGE: (1) Plug the charger’s power cord into the charger.
WARNING
To avoid damage to battery pack contacts, always check that the vacuum’s power switch is OFF before disconnecting or reconnecting the battery pack. (2) When connecting battery pack to vacuum or charger, firmly press into place. Install battery on charger as shown. Plug the charger’s power cord into 120V wall outlet. The LED lights will remain off until a battery is inserted into the charger.
After inserting a battery into the charger, the charging indicator light will flash green while charging and the full indicator light will turn green when fully charged. Refer to the Owner’s Manual for approximate charge times.
NOTE: Batteries cannot be shipped fully charged, only partially charged. Please follow these steps to fully charge your new battery. Verify the charge level of the battery pack by pressing the power level indicator button on the front of the battery pack. Four green lights indicate a fully charged battery.
Remove battery from charger and unplug cord from wall outlet after charging. Battery pack may get warm while charging. Holding battery by the front handle, carefully slide the battery into the vacuum’s lower housing, aligning the slides of the battery and lower housing. Connectors are spring-loaded. Battery will need to be pushed fully into position. BATTERY FUEL GAUGE
The battery fuel gauge indicates the approximate run time remaining on the battery. When the test button is pressed, one to five indicators will light up, indicating the approximate battery charge remaining as follows:
All 4 lights on: Full Charge
4 lights on: 80% – 100%
3 lights on: 60% – 80%
2 lights on: 40% – 60%
1 light on: 20%-40%
1 Flashing light on: Less than 20%

ATTACHING WAND AND TOOLS: For the standard configuration accessories, follow these instructions. Different wands/ tools may have different connections.
Fasten the ends of the wands together. Pull back to open purple latch on lower half of the wand.
Find the notch on the inside of lower half and the groove on the outside of the upper half – they must align. Insert the upper half into the lower by aligning the notch and groove. To tighten into position, close the purple latch when wand is at desired height. If wand does not stay at desired height, pull open the purple latch, tighten the Phillips screw as necessary, and close the purple latch again. Twist the wand into the end of the hose. Attach the floor tool to end of wand. Align the brass ring with the groove on the floor tool to ensure a secure fit. After inserting a battery pack into the lower housing of the vacuum, press the power button once to turn on the vacuum on HI mode. Press the power button a second time to turn the vacuum to LO mode. Pressing the power button a third time will turn off the vacuum. Draw the top of the wand in toward your waist and twist at the waist walking backward or forward, in a side-to-side motion.

MAINTAINING YOUR VACUUM

POST THIS INFORMATION FOR REFERENCE NEAR THE LOCATION YOU STORE THE VACUUM.
SAFE CLEANING PRACTICES:
WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY REFER TO OWNER’S MANUAL FOR ALL SAFETY WARNINGS! REVIEW the SAFETY LABEL on the vacuum. For additional safety information, read the vacuum owner’s manual. DO NOT vacuum liquids or expose the vacuum to rain or water.
DO NOT use the vacuum outdoors or on wet surfaces.
DO NOT handle the vacuum or battery pack with wet hands. DO NOT vacuum flammable or combustible materials or anything that is burning or smoking, such as cigarettes, matches or ashes. ALWAYS hold the plug, not the cord, when plugging in or unplugging the battery charger.

WEARING THE VACUUM:
HARNESS HEIGHT ADJUSTMENT
Follow the purple numbers 1-4 for the perfect fit Upper harness should sit between shoulder blades for most comfortable fit. The upper harness can be adjusted by sliding the upper harness along the Quick Adjust track (See side view of vacuum and harness to the left).
DO NOT adjust harness height while wearing the backpack.ProTeam GoFitTM6
HEPA Media Vacuum Unit - WEARING 1To move the upper harness, pull on the purple tab located between the upper harness pad and the vacuum to release the locking feature (A). Maintain upward pressure on this pull tab and slide the upper harness identified with a purple “1”, to the desired location before releasing the tab (B). Ensure the upper pad is locked by gently pulling on the carry handle to make sure there is no further movement. Loosen the shoulder straps and the waist belt. Lift the vacuum and slide your arms through the straps.ProTeam
GoFitTM6 HEPA Media Vacuum Unit - AJUSTEMENT 2Connect the waist strap. Tighten the waist belt by grabbing the ends of the straps and pulling them toward each other and then directly outward from the center of the body. It is very important that the weight of the unit be concentrated on your hips rather than your shoulders. Adjust the shoulder straps so that the unit fits comfortably, with the weight concentrated on your hips. Connect the sternum strap and slide the strap up or down on the sewn-in wire support for the best fit.

FILTER MAINTENANCE:
USE ONLY GENUINE PROTEAM FILTERS TO ENSURE OPTIMAL PERFORMANCE, IMPROVED INDOOR AIR QUALITY AND MAINTAIN A VALID VACUUM WARRANTY.

  1. **** INTERCEPT MICRO® FILTER
    EMPTY and INSPECT the Intercept Micro Filter every time you start and finish vacuuming. Replace the filter if necessary. A clogged and dirty filter restricts airflow and results in overheating and reduced suction. To replace the Intercept Micro Filter, slide filter into Cloth Filter and secure into vacuum body.

  2. CLOTH FILTER WARNING:
    To reduce the risk of fire, electric shock or injury, do not use the vacuum with a wet cloth filter bag or dome filter. Allow the filters to dry completely before reinstalling.
    Once a month, or as necessary, hand or machine wash the cloth filter and let it AIR dry.
    DO NOT PUT IT IN THE DRYER.

  3. HEPA MEDIA DOME FILTER Once a week, or as necessary, inspect or replace the HEPA Media Dome Filter. First, remove the Intercept Micro Filter and Cloth Filter. Reach into the vacuum body and twist dome filter from motor.

ProTeam GoFitTM6 HEPA Media Vacuum Unit - AJUSTEMENT 8

ProTeam, Inc.
ph 866.888.2168
fax 800.844.4995
proteam.emerson.com The American Lung Association does
not endorse product, device or service.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ProTeam User Manuals

Related Manuals