SAFEWAZE FS-EX311 Standing Seam Roof Anchor Instruction Manual

June 1, 2024
SAFEWAZE

SAFEWAZE-logo

SAFEWAZE FS-EX311 Standing Seam Roof Anchor

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-product

Product Information

Specifications

  • Product Name: FS-EX311 Standing Seam Roof Anchor
  • Compliance: Meets OSHA 1926.502, 1910.140, 1910.66, ANSI Z359.1 standards

Frequently Asked Questions

  • Q: How should I store the FS-EX311 Standing Seam Roof Anchor when not in use?
    • A: The anchor should be stored in a dry, well-ventilated area away from direct sunlight and corrosive materials.
  • Q: Can the FS-EX311 be used in all weather conditions?
    • A: The anchor is suitable for use in various weather conditions, but it is recommended to inspect it regularly for any signs of wear or damage.

Information

WARNING

This product is part of a personal fall arrest, work positioning, suspension or rescue system. The manufacturer’s instructions must be provided to users of this equipment. The user must follow the manufacturer’s instructions for each component of the system. The user must read and understand these instructions before using this equipment. Manufacturer’s instructions must be followed for proper use and maintenance of this equipment. Alterations to this product, misuse of this product, or failure to follow instructions may result in serious injury or death.

IMPORTANT

Questions regarding the use, care, or suitability of this equipment for your application? Contact Safewaze.

IMPORTANT

Record identification information before using this product. Identification information may be found on the equipment label. This information should be recorded in the “Inspection Log” located at the back of this manual

  • OSHA 1926.502, 1910.140, 1910.66

This manual is intended to meet the manufacturer’s instructions as required by ANSI Z359 and should be used as part of an employee training program as required by OSHA.

User Information

  • Date of First Use:
  • Serial#:
  • Trainer:
  • User:

Do not throw away these instructions!

Read and understand these instructions before using equipment!

INTRODUCTION

Thank you for purchasing the Safewaze FS-EX311 Standiing Seam Roof Anchor. This manual must be read and understood in its entirety, and used as part of an employee training program as required by OSHA or any applicable state agency. This manual and any other instructional material must be available to the user of the equipment. The user must understand how to safely and effectively use the FS-EX311, and all fall protection equipment used in conjuction with the anchor.

APPLICABLE SAFETY STANDARDS

When used according to instructions, the FS-EX311 Standing Seam Roof Anchor meets all applicable ANSI Z359.1 standards and OSHA regulations for fall protection. Applicable standards and regulations depend on the type of work being done, and may include state-specific regulations. Refer to local, state, and federal (OSHA) requirements for additional information concerning the governing of occupational safety regarding Personal Fall Arrest Systems (PFAS).

WORKER CLASSIFICATIONS

Understand the definitions of those who work in proximity of or may be exposed to fall hazards.

  • Qualified Person: “Qualified” means one who, by possession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience, has successfully demonstrated his ability to solve or resolve problems relating to the subject matter, the work, or the project.
  • Competent Person: “Competent person” means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
  • Authorized Person: “Authorized person” means a person approved or assigned by the employer to perform a specific type of duty or duties or to be at a specific location or locations at the job site.

It is the responsibility of a Qualified or Competent person to supervise the job site and ensure safety regulations are complied with.

PRODUCT SPECIFIC APPLICATIONS

Purpose: The Safewaze FS-EX311 Standing Seam Roof Anchor is designed to be used as part of a Personal Fall Arrest System (PFAS).

  • A competent person shall train users on this equipment in accordance with OSHA and ANSI.
  • Never exceed a free fall distance of 6 ft. A free fall of more than 6 ft could cause excessive arrest forces that could result in serious injury or death.
  • The Safewaze FS-EX311 Standing Seam Roof Anchor has a maximum capacity of 310 lbs including any tools, clothing, accessories, etc…, unless otherwise rated by Safewaze.
  • Structures for attachment of Safewaze FS-EX311 Standing Seam Roof Anchor shall support a minimum 5,000 lbs or be designed with a safety factor of two by a Qualified Person.
  • All Safewaze anchors must IMMEDIATELY be removed from service if subjected to fall arrest forces.
  • Safewaze anchors shall be inspected by the end user prior to each usage and by a Competent Person other than the user every 6 months. These inspections shall be documented.

LIMITATIONS

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-1

  • Fall Clearance: There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction. When calculating fall clearance, account for a MINIMUM 2’ safety factor, deceleration distance, user height, length of lanyard/SRL, and all other applicable factors. (See Figure 1)
  • Swing Falls: Prior to installation or use, make considerations for eliminating or minimizing all swing fall hazards. Swing falls occur when the anchor is not directly above the location where a fall occurs. Always work as close to in line with the anchor point as possible. Swing falls significantly increase the likelihood of serious injury or death in the even of a fall. (See Figure 2)

COMPATIBILITY OF CONNECTORS

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-3

Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how they become oriented. Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22.2 kN). Connectors must be compatible with the anchorage or other system components (see Figure 4). Do not use equipment that is not compatible. Non-compatible connectors may unintentionally disengage (see Figure 3). Connectors must be compatible in size, shape, and strength. Self-locking snap hooks and carabiners are required by ANSI Z359 and OSHA guidelines. Contact Safewaze if you have any questions about compatibility.

NOTE: SOME SPECIALITY CONNECTORS HAVE ADDITIONAL REQUIREMENTS. CONTACT SAFEWAZE WITH QUESTIONS.

Using a connector that is undersized or irregular in shape (1) to connect a snap hook or carabiner could allow the connector to force open the gate of the snap hook or carabiner. When force is applied, the gate of the hook or carabiner presses against the non-compliant part (2) and forces open the gate (3). This allows the snap hook or carabiner to disengage (4) from the connection point.

MAKING CONNECTIONS

Snap hooks and carabiners used with this equipment must be double locking and/or twist lock. Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked.

Safewaze connectors (snap hooks and carabiners) are designed to be used only as specified in each product’s user’s instructions. See figure 4 for examples of inappropriate connections. Do not connect snap hooks and carabiners:

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-4

  • To a D-ring to which another connector is attached.
  • In a manner that would result in a load on the gate (with the exception of tie back hooks). NOTE: Large snap hooks must not be connected to objects which will result in a load on the gate if the hook twists or rotates. Snap hooks marked with ANSI Z359.12 and are equipped with a 3,600 lb (16 kN) gate. Check the marking on your snap hook to verify its compatibility.
    • NOTE: Large throat snap hooks must not be connected to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless the snap hook complies with ANSI Z359.1-2007 or ANSI Z359.12 and is equipped with a 3,600 lb (16 kN) gate. Check the marking on your snap hook to verify that it is appropriate for your application.
  • In a false engagement, where features that protrude from the snap hook or carabiner catch on the anchor, and without visual confirmation seems to be fully engaged to the anchor point.
  • To each other.
  • By wrapping the web lifeline around an anchor and securing to lifeline except as allowed for Tie Back models.
  • To any object which is shaped or sized in a way that the snap hook or carabiner will not close and lock, or that roll-out could occur.
  • In a manner that does not allow the connector to align properly while under load.

SPECIFIC ANCHOR APPLICATIONS

  • Personal Fall Arrest: The FS-EX311 Standing Seam Roof Anchor is designed as an anchor point to support a maximum of 1 Personal Fall Arrest System (PFAS) when utilized for fall protection applications. The structure to which the anchor is attached must withstand loads applied in the directions permitted by the system of at least 5,000 lbs. Maximum allowable free fall is 6’.
  • Restraint: The FS-EX311 Standing Seam Roof Anchor is authorized for use in Restraint applications. The structure to which the anchor is attached must withstand loads applied in the directions permitted by the system of at least 1,000 lbs. NO free fall is permitted. Restraint systems may only be used on surfaces with slopes up to 4/12 (vertical / horizontal). For Restraint applications, the allowable attachment points to harness are Dorsal D-ring, Chest D-ring, Side D-rings, and Shoulder D-rings.
  • Work Positioning: The FS-EX311 Standing Seam Roof Anchor is authorized for use in Work Positioning applications. Work Positioning allows a worker to be supported during suspension while freeing both hands to conduct work operations. The structure to which the Chain Anchor is attached must withstand loads applied in the directions permitted by the system of at least 3,000 lbs. Maximum allowable free fall is 2’. For positioning applications, the allowable attachment points to harness are the Side D-rings.
  • Rescue/Confined Space: The FS-EX311 Standing Seam Roof Anchor is authorized for use in Rescue/Confined Space applications. Rescue systems are utilized to safely recover a worker from a confined location or after exposure to a fall. Composition of rescue systems can vary based upon the type of rescue involved. The structure to which a Chain Anchor is attached must withstand loads applied in the directions permitted by the system of at least 3,000 lbs. NO free fall is permitted. For rescue applications, the allowable attachment points to harness are Dorsal D-ring, Chest D-ring and Shoulder D-rings.

All above referenced applications have a worker weight capacity range of 310 lbs (including all clothing, tools, and equipment).

STANDING SEAM ROOF ANCHOR COMPONENTS

FS-EX311 STANDING SEAM ROOF ANCHOR COMPONENTS

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-9

  • A. PFAS Attachment Point
  • B. Side Plate
  • C. Seam Clamp Point
  • D. Side Plate
  • E. Tightening Bolts

INSTALLATION

  1. Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that meets the strength requirement, minimizes free fall, and reduces swing fall hazards. Do not work above the anchorage point.
  2. The FS-EX311 Standing Seam Roof Anchor can be installed on any structure that meets the strength requirements as defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal Fall Arrest.
  3. The FS-EX311 Standing Seam Roof anchor is a rated roof anchor point designed for sloped or flat roofs. The Standing Seam roof deck must be rated to meet OSHA, federal, state, and local government regulations for fall protection anchor points. MINIMUM required substrate thickness is 24 gauge.
  4. The FS-EX311 Standing Seam Roof Anchor is NOT suitable for use with Horizontal Lifelines.
  5. Choose an installation location directly over a clip that is screwed/bolted down, and ensure that the enire panel is fully seamed.
  6. To install the FS-EX311 Standing Seam Roof Anchor the user will first loosen the 4 Tightening Bolts. This allows the two side plates to seperate a sufficient distance for installation onto the standing seam (See Figure 6).
  7. Once the FS-EX311 is opened wide enough to allow the standing seam to be enclosed in the anchor, the user will then tighten the bolts to 50 ft. lbs. starting with the top two bolts first (See Figure 7). Once all bolts are tightened, the bolts should be loosened once again and retightened on the standing seam. This ensures proper compression of any open space within the seam.
  8. The allowable working radius of the FS-EX311 Standing Seam Roof Anchor is 30° in line with the anchor (See Figure 8).

INSTALLATION EXAMPLE

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-10

PRECAUTION

WARNING

  • Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event. Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall arrest forces. Women who are pregnant, individuals considered minors must not use any Safewaze equipment.
  •  Never alter any part of a lanyard or add/remove components. Safewaze shall not be held responsible for injury or death due to tampering.
  • Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and destroyed.
  • Failure to follow these instructions and warnings could result in serious injury or death in the event of a fall.
  • A preplanned rescue procedure in the event of a fall is required. The rescue plan must be specific to the project. The rescue plan must allow for employees to rescue themselves, or to be promptly rescued by alternative means.
  • Harnesses or connectors selected for use with any Safewaze anchor must be compatible in size and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors. Any connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be self locking and self closing and must never be hooked to each other.
  • A Competent Person must conduct an analysis of the workplace and anticipate where workers will be conducting their duties, the route they will take to reach their work, and the existing and potential fall hazards they may be exposed to. The Competent Person must choose the fall protection equipment to be utilized.
  • Do not misuse equipment.
  • Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or equipment unless specifically certified for such use.

INSPECTION

  • Safewaze Anchors shall be inspected prior to each use by the user and at least every 6 months by a Competent Person. Annual inspections shall be documented. Severity of conditions during use may necessitate increased frequency of documented inspections.
  • Anchors that fail inspection MUST be removed from service.
  • Prior to each use, inspect the FS-EX311 Satnding Seam Roof Anchor for deficiencies or damage, including, but not limited to, sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme heat exposure, or missing or illegible labels. If any deficiencies or defects are found, the FS-EX311 must IMMEDIATELY be removed from service.
  • The FS-EX311 Standing Seam Roof Anchor must be inspected at least every 6 months by a Competent Person other than the user. Competent person inspections must be recorded in the inspection log included in this manual and on the inspection grid label on the FS-EX311.

WARRANTY AND MAINTENANCE

WARRANTY

  • Safewaze warrants its products are free from defects in materials and construction under normal use and service.
  • Liability is not accepted for abuse, modification, improper use, destructive activity and contaminated exposure.

MAINTENANCE & STORAGE 

  • The FS-EX311 Standing Seam Roof Anchor can be cleaned with water and mild soap if necessary. User should remove all dirt, possible corrosives, and contaminants from the anchor prior to, and after each use. Never use any type of corrosive substance to clean the FS-EX311.
  • Excess water should be blown out with compressed air. Hardware can be wiped off with a clean, dry cloth.
  • When not in use, store the FS-EX311 Standing Seam Roof Anchor in a cool dry area where it will not be exposed to extreme light, extreme heat, excessive moisture, or possibly corrosive chemicals or materials.

LABELS

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-11

INSPECTION LOG

SAFEWAZE-FS-EX311-Standing-Seam-Roof-Anchor-fig-12

Contact

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals