TechniSat 2266186 Z-Wave, Z-Wave+ Blinds actuator User Manual

June 4, 2024
TechniSat

2266186 Z-Wave, Z-Wave+ Blinds actuator
User Manual

2266186 Z-Wave, Z-Wave+ Blinds actuator

Please keep this page with the full device-specific key (DSK) in a safe place!
It is needed throughout the entire product’s lifetime

Safety warnings

**INSTALLATION**

  1. To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
  2. Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
  3. Take extra precautions to avoid accidentally turning on the device during installation.
  4. Connect the device according to the wiring diagram.

Danger of electrocution!
Installation of this device requires a great degree of skill and may be performed only by a licensed and qualified electrician. Please keep in mind that even when the device is turned off, the voltage may still be present in the device’s terminals.

IMPORTANT DISCLAIMER

Wireless communication is not always 100% reliable. This device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the device is not recognized by your gateway (hub) or shows up incorrectly, you may need to change the device type manually and make sure your gateway (hub) supports Z-Wave Plus devices.
WARNING
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal free of charge.
Z-Wave
This product can be operated in any Z-Wave network with other Z-Wave-certified devices from other manufacturers. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
Z-Wave Plus
This device is a security-enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate with other security-enabled Z-Wave Plus products.
This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.

Key features

The TechniSat Shutter is designed to control a roller shutter

  • In-wall-mounted shutter control
  • Z-Wave Plus
  • Security S2
  • SmartStart
  • compatible with German market wall switch product lines
  • Overload protection

Overview

Front
TechniSat 2266186 Z Wave Z Wave Blinds actuator -
Front Back
TechniSat 2266186 Z Wave Z Wave Blinds actuator - Back
L Live lead
1 Switched output to shutter motor – up direction
2 Switched output to shutter motor – down  direction
N Neutral lead

**Wiring diagram

**

TechniSat 2266186 Z Wave Z Wave Blinds actuator - Wiring
diagram

SmartStart inclusion

SmartStart-enabled products can be added to a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

  1. The Z-Wave QR-Code is located on the back of the product.
  2. Please follow your SmartStart-enabled Z-Wave gateway‘s manual, on how to use SmartStart inclusion.
  3. Install the TechniSat Shutter.
  4. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker
  5. The TechniSat Shutter will be added to your Z-Wave network within 10 minutes after re-enabling electrical power.

Manually adding the device to the Z-Wave network

  1. Install the TechniSat Shutter.
  2. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker.
  3. Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual.
  4. Press T1 3x within 1 second.
  5. The red status LED is on while the device is added to the Z-Wave network.
  6. The green LED is on for 5 seconds after successfully adding the device.

Removing the device from the Z-Wave network

  1. Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway‘s manual.
  2. When the roller shutter is in the uppermost position, press and holds T1 for more than 10 seconds.
  3. The red status LED is on while the device is removed from the Z-Wave network.
  4. The green LED is on for 5 seconds after successfully removing the device.

Factory Default Reset

Use this procedure only when the network primary controller is missing or otherwise inoperable.

  1. When the roller shutter is in the lowermost position, press and holds T2 for more than 20 seconds.
  2. The LED will alternately flash red and green for 5 seconds after a successful reset.

Configuration

Parameter| Description| Size (Bytes)| Value|

Default

---|---|---|---|---
1| Enable/Disable Central scene notifications for 2x-5x press| 1| 0  – disable 1 – enable| 1
2| Interval of current wattage meter report in 10 seconds| 2| 0 – disable unsolicited reports
3 … 8640 (30 seconds – 1 day)| 3 (the 30s)
3| Interval of active energy meter report in minutes| 2| 0 – disable unsolicited reports
10 … 30240 (10 minutes – 3 weeks)| 60 (1 hour)
4| Manual shutter calibration (Shutter will move up, down, and up again)| 1| 0 – idle
1 – start a manual shutter calibration| 0

Supported Association Groups

ID| Name| Max group members|

CC-Commands

---|---|---|---
1| Lifeline| 1| –  Device Reset Locally Notification
–  Central Scene notification
–  Meter Report
–  Multilevel Switch Report
–  Notification Report
2| Switch State| 10| – Basic Set

Basic Command Class

This device controls members of association group 2 with Basic Command Class Set commands. The set commands mirror the device‘s state.
When the device is set to a multilevel value, the same value is sent as a Basic Set to members in association group 2.

Notification Command Class

Notification Type Notification Event Description
Power Management (0x08) Idle (0x00) No event detected / event cleared
Overload detected (0x08) The maximum load on outputs 1 or 2 to the shutter

motor has been exceeded

Supported Command Classes documentation

Command Class Version Required Security Class
Association 2 highest granted
Association Group Information 1 highest granted
Basic 2 highest granted
Central Scene 3 highest granted
Configuration 1 highest granted
Device Reset Locally 1 highest granted
Firmware Update Meta Data 4 highest granted
Manufacturer Specific 2 highest granted
Meter 4 highest granted
Multilevel Switch 4 highest granted
Notification 8 highest granted
Powerlevel 1 highest granted
Security 0 1 none
Security 2 1 none
Supervision 1 none
Transport Service 2 none
Version 3 highest granted
Z-Wave Plus Info 2 none

Central Scene

The TechniSat Shutter can send central scene activation notifications to a Z-Wave gateway.
Pressing the respective button multiple times will send the corresponding scene number:

Button T1 T2 T3 T4
Scene number 1 2 3 4

The following Z-Wave key attributes are available for all scenes:

Button pressed Z-Wave key attribute
two times Key Pressed 2 times
three times Key Pressed 3 times
four times Key Pressed 4 times
five times Key Pressed 5 times

Firmware update

This device supports firmware updates via Z-Wave. For enhanced security, the device requires a manual confirmation, before an update of the device‘s firmware can be initiated.
To perform a firmware update follow these steps:

  1. Follow your Z-Wave gateway‘s manual, on how to update the firmware of a Z-Wave device.
  2. From your gateway issue a Z-Wave request to get the current firmware version of the device to be updated.
  3. When the request has been received, your device‘s LED will glow red for 10 seconds.
  4. While the LED glows red, press T1, T2, T3, or T4 to allow a firmware update – the LED will now glow green for 10 seconds.
  5. While the LED glows green, start the device‘s firmware update from your gateway.

Technical Data

Product Key Features| In-wall mounted shutter control! Z-Wave Plus
Security S2 SmartStart
compatible with German market wall switch product lines
Overload protection
---|---
supply voltage| 230 VAC +/- 10 %
line frequency| 50 Hz +/- 10 %
the rated load current of output (resistive load)| 1,7 A
IEC protection class| Schutzklasse II
IP protection class| IP20
Z-Wave frequency transmission power| 868,42 MHz 4 dBm
Status LED| The red status LED is on during the inclusion process
Red blinking – overload protection
Green LED is on for 5 s after successful inclusion
Ambient Conditions Operational| Temperature: +5 °C to +35 °C Humidity: 10 % to 75 % RH
Ambient Conditions Warehousing & Transport:| Temperature: -20 °C to +60 °C Humidity: 5 % to 90 % RH non condensing
Dimensions (WxHxD)| 70 mm x 70 mm x 45 mm

Subject to technical changes and errors.
Subject to change for amendments and printing errors.
Last updated: 01/20
Duplication and reproduction only with the publisher‘s approval.
TechniSat is a registered trademark of:
TechniSat Digital GmbH
PO box 560
54541 Daun (Germany)
www.technisat.com
Technical Hotline
Mon. – Fri. 8:00 – 18:00
03925/9220 1800
Caution!
If you encounter a problem with this equipment, please contact our Technical Hotline initially.
Z-Wave and Z-Wave Plus have registered trademarks of Silicon Laboratories and its subsidiaries in the United States and other countries.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals