- Safety warnings
- IMPORTANT DISCLAIMER
- Key features
- Overview
- **Wiring diagram
- SmartStart inclusion
- Manually adding the device to the Z-Wave network
- Removing the device from the Z-Wave network
- Factory Default Reset
- Configuration
- Supported Association Groups
- Basic Command Class
- Notification Command Class
- Supported Command Classes documentation
- Central Scene
- Firmware update
- Technical Data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
2266186 Z-Wave, Z-Wave+ Blinds actuator
User Manual
2266186 Z-Wave, Z-Wave+ Blinds actuator
Please keep this page with the full device-specific key (DSK) in a safe place!
It is needed throughout the entire product’s lifetime
Safety warnings
**INSTALLATION**
- To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
- Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
- Take extra precautions to avoid accidentally turning on the device during installation.
- Connect the device according to the wiring diagram.
Danger of electrocution!
Installation of this device requires a great degree of skill and may be
performed only by a licensed and qualified electrician. Please keep in mind
that even when the device is turned off, the voltage may still be present in
the device’s terminals.
IMPORTANT DISCLAIMER
Wireless communication is not always 100% reliable. This device should not be
used in situations in which life and/or valuables are solely dependent on its
functioning. If the device is not recognized by your gateway (hub) or shows up
incorrectly, you may need to change the device type manually and make sure
your gateway (hub) supports Z-Wave Plus devices.
WARNING
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated
to take back your old appliance for disposal free of charge.
Z-Wave
This product can be operated in any Z-Wave network with other Z-Wave-certified
devices from other manufacturers. All non-battery-operated nodes within the
network will act as repeaters regardless of vendor to increase the reliability
of the network.
Z-Wave Plus
This device is a security-enabled Z-Wave Plus product that is able to use
encrypted Z-Wave Plus messages to communicate with other security-enabled
Z-Wave Plus products.
This device must be used in conjunction with a Security Enabled Z-Wave
Controller in order to fully utilize all implemented functions.
Key features
The TechniSat Shutter is designed to control a roller shutter
- In-wall-mounted shutter control
- Z-Wave Plus
- Security S2
- SmartStart
- compatible with German market wall switch product lines
- Overload protection
Overview
Front
Back
L Live lead
1 Switched output to shutter motor – up direction
2 Switched output to shutter motor – down direction
N Neutral lead
**Wiring diagram
**
SmartStart inclusion
SmartStart-enabled products can be added to a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
- The Z-Wave QR-Code is located on the back of the product.
- Please follow your SmartStart-enabled Z-Wave gateway‘s manual, on how to use SmartStart inclusion.
- Install the TechniSat Shutter.
- After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker
- The TechniSat Shutter will be added to your Z-Wave network within 10 minutes after re-enabling electrical power.
Manually adding the device to the Z-Wave network
- Install the TechniSat Shutter.
- After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker.
- Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual.
- Press T1 3x within 1 second.
- The red status LED is on while the device is added to the Z-Wave network.
- The green LED is on for 5 seconds after successfully adding the device.
Removing the device from the Z-Wave network
- Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway‘s manual.
- When the roller shutter is in the uppermost position, press and holds T1 for more than 10 seconds.
- The red status LED is on while the device is removed from the Z-Wave network.
- The green LED is on for 5 seconds after successfully removing the device.
Factory Default Reset
Use this procedure only when the network primary controller is missing or otherwise inoperable.
- When the roller shutter is in the lowermost position, press and holds T2 for more than 20 seconds.
- The LED will alternately flash red and green for 5 seconds after a successful reset.
Configuration
Parameter| Description| Size (Bytes)| Value|
Default
---|---|---|---|---
1| Enable/Disable Central scene notifications for 2x-5x press| 1| 0 – disable
1 – enable| 1
2| Interval of current wattage meter report in 10 seconds| 2| 0 – disable
unsolicited reports
3 … 8640 (30 seconds – 1 day)| 3 (the 30s)
3| Interval of active energy meter report in minutes| 2| 0 – disable
unsolicited reports
10 … 30240 (10 minutes – 3 weeks)| 60 (1 hour)
4| Manual shutter calibration (Shutter will move up, down, and up again)| 1| 0
– idle
1 – start a manual shutter calibration| 0
Supported Association Groups
ID| Name| Max group members|
CC-Commands
---|---|---|---
1| Lifeline| 1| – Device Reset Locally Notification
– Central Scene notification
– Meter Report
– Multilevel Switch Report
– Notification Report
2| Switch State| 10| – Basic Set
Basic Command Class
This device controls members of association group 2 with Basic Command Class
Set commands. The set commands mirror the device‘s state.
When the device is set to a multilevel value, the same value is sent as a
Basic Set to members in association group 2.
Notification Command Class
Notification Type | Notification Event | Description |
---|---|---|
Power Management (0x08) | Idle (0x00) | No event detected / event cleared |
Overload detected (0x08) | The maximum load on outputs 1 or 2 to the shutter |
motor has been exceeded
Supported Command Classes documentation
Command Class | Version | Required Security Class |
---|---|---|
Association | 2 | highest granted |
Association Group Information | 1 | highest granted |
Basic | 2 | highest granted |
Central Scene | 3 | highest granted |
Configuration | 1 | highest granted |
Device Reset Locally | 1 | highest granted |
Firmware Update Meta Data | 4 | highest granted |
Manufacturer Specific | 2 | highest granted |
Meter | 4 | highest granted |
Multilevel Switch | 4 | highest granted |
Notification | 8 | highest granted |
Powerlevel | 1 | highest granted |
Security 0 | 1 | none |
Security 2 | 1 | none |
Supervision | 1 | none |
Transport Service | 2 | none |
Version | 3 | highest granted |
Z-Wave Plus Info | 2 | none |
Central Scene
The TechniSat Shutter can send central scene activation notifications to a
Z-Wave gateway.
Pressing the respective button multiple times will send the corresponding
scene number:
Button | T1 | T2 | T3 | T4 |
---|---|---|---|---|
Scene number | 1 | 2 | 3 | 4 |
The following Z-Wave key attributes are available for all scenes:
Button pressed | Z-Wave key attribute |
---|---|
two times | Key Pressed 2 times |
three times | Key Pressed 3 times |
four times | Key Pressed 4 times |
five times | Key Pressed 5 times |
Firmware update
This device supports firmware updates via Z-Wave. For enhanced security, the
device requires a manual confirmation, before an update of the device‘s
firmware can be initiated.
To perform a firmware update follow these steps:
- Follow your Z-Wave gateway‘s manual, on how to update the firmware of a Z-Wave device.
- From your gateway issue a Z-Wave request to get the current firmware version of the device to be updated.
- When the request has been received, your device‘s LED will glow red for 10 seconds.
- While the LED glows red, press T1, T2, T3, or T4 to allow a firmware update – the LED will now glow green for 10 seconds.
- While the LED glows green, start the device‘s firmware update from your gateway.
Technical Data
Product Key Features| In-wall mounted shutter control! Z-Wave Plus
Security S2 SmartStart
compatible with German market wall switch product lines
Overload protection
---|---
supply voltage| 230 VAC +/- 10 %
line frequency| 50 Hz +/- 10 %
the rated load current of output (resistive load)| 1,7 A
IEC protection class| Schutzklasse II
IP protection class| IP20
Z-Wave frequency transmission power| 868,42 MHz 4 dBm
Status LED| The red status LED is on during the inclusion process
Red blinking – overload protection
Green LED is on for 5 s after successful inclusion
Ambient Conditions Operational| Temperature: +5 °C to +35 °C Humidity: 10 % to
75 % RH
Ambient Conditions Warehousing & Transport:| Temperature: -20 °C to +60 °C
Humidity: 5 % to 90 % RH non condensing
Dimensions (WxHxD)| 70 mm x 70 mm x 45 mm
Subject to technical changes and errors.
Subject to change for amendments and printing errors.
Last updated: 01/20
Duplication and reproduction only with the publisher‘s approval.
TechniSat is a registered trademark of:
TechniSat Digital GmbH
PO box 560
54541 Daun (Germany)
www.technisat.com
Technical Hotline
Mon. – Fri. 8:00 – 18:00
03925/9220 1800
Caution!
If you encounter a problem with this equipment, please contact our Technical
Hotline initially.
Z-Wave and Z-Wave Plus have registered trademarks of Silicon Laboratories and
its subsidiaries in the United States and other countries.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>