TechniSat HT2 Heating Thermostat User Manual

June 2, 2024
TechniSat

TechniSat logo

TechniSat HT2 Heating Thermostat

TechniSat HT2 Heating Thermostat

Many thanks for choosing a product of TechniSat Digital GmbH. The following quick start set up guide will help you installing your heating thermostat HT2. Please read this manual carefully before using and keep it around when installing the product. For questions and information please contact your TechniSat reseller / distributor or use our technical hotline via +49 3925/9220 1800.

Included in delivery

  1. Heating thermostat HT2
  2. Screw
  3. Adapters for Danfoss valves
  4. 2x AA batteries

TechniSat HT2 Heating Thermostat 1

*When using the RAV adapter you need to use the RAV Pin for the extension of the valve stem.

IMPORTANT INSTRUCTIONS

WARNING- Do not use rechargeable batteries!
Never recharge batteries, do not short circuit them, do not take them apart – Risk of explosion!
Remove dead batteries immediately and remove them from the device. Not use new and used batteries together. Keep batteries away from children.
Avoid contact with skin, eyes and skin. If getting contact with battery acid please immediately clean the affected areas with plenty of clear water and visit a doctor.

SAFETY INSTRUCTIONS

  • The device is intended for use in buildings
  • Only operate the device as described in the operating instructions
  • The device should only be used in a dry and dust free place without direct sunlight
  • Stop using the device if it has obvious damage

The device must be not be rebuilt, modified or be opened.

Product description

The heating thermostat HT2 is a Z-Wave plus radio standard compatible energy saving radiator thermostat.

FLiRS (Frequently Listening Receiver Slave):
The heating thermostate HT2 uses FLiRS to provide short latency and short responding times.

Technical specifications

  • Device: Heating Thermostate HT2
  • EAN: 4019588095199
  • Art.nr: 0000/9519
  • Supply voltage: 2x 1,5V /AA
  • Radio frequency: 868,42 MHz
  • Connection: M30 x 1,5mm
  • Method of operation: Type 1
  • Dimensions: (W x H xD) 56 x 68 x 89 mm
  • Weight: 176 g
  • Degree of protection: IP20
  • Degree of pollution: 2

Buttons and display

Buttons

TechniSat HT2 Heating Thermostat 2

Result/BehaviourTechniSat HT2 Heating Thermostat 3

  • Decrease temperature by 0.5C
  • Decrease room temperature by 0.5C and lower the room temperature by 0.5C every 0.5 seconds or until the lowest temperature is set
  • Increase room temperature by 0.5C
  • Increase room temperature by 0.5C and raise the room temperature by 0.5C every 0.5 seconds or until the highest temperature is set.
    • Confirm action which is displayed in the LCD
    • Switch into Boost-Mode (Quick Heat)
    • Quit Boost-mode (Quick Heat) if currently active.
  • The LCD shows the Z-Wave Node ID.
  • The heating thermostat HT2 will react to Exclusion Commands Allows factory reset of the heating thermostat HT2.
  • Sets or clears the child protection.

Boost-button LEDsTechniSat HT2 Heating Thermostat
4TechniSat HT2 Heating Thermostat 5

LCD

Wrench:
Lights up if mechanical tasks are opening

Antenna :
Displays the HT2 network state. Segment visible: rf-link established / Segment turned off: rf-link lost

ID : Lights up if the display shows the Z-Wave NodeID

Battery : Lights up if less than 15% battery is remaining

Lock : Lights up if child protection is set

Celsius : Displayed if the LCD shows a setpoint temperature


Percent
: Displayed instead of C Icon if the HT2 is set to direct control mode

Inserting batteries
Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct polarity! At a later battery change, the configuration of your HT2 is maintained.TechniSat HT2 Heating Thermostat
8

Inclusion
Start inclusion mode of your primary Z-Wave controller. Press the Boost- Button. The heating thermostat HT2 will show the assigned Node ID.TechniSat
HT2 Heating Thermostat 9TechniSat HT2 Heating Thermostat
10

Mounting the heating thermostat HT2
After adding the HT2 to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet. If successfully installed to the radiator proceed with 4.6.

Installation at the radiator without adapter

TechniSat HT2 Heating Thermostat 11

Installation at the radiator with adapterTechniSat HT2 Heating
Thermostat 12

Mechanical installation
Press the boost button to start the mechanical installation.TechniSat HT2
Heating Thermostat 13TechniSat HT2 Heating Thermostat
14

Exclusion
Start Exclusion mode of your primary Z-Wave controller. Now press and hold the boost button of the HT2 for at least 5 seconds.TechniSat HT2 Heating
Thermostat 15

Unmounting the heating thermostat HT2
Remove the HT2 from the Z-Wave network before unmounting it. Follow the process described in Exclusion and wait until the LCD shows INC. You can now uninstall the HT 2 from the radiator.TechniSat HT2 Heating Thermostat
16

Factory reset

Remove batteries. Press and hold boost button. While still holding boost button insert batteries. The LCD shows RES. Release boost button. To perform the factory reset press boost button.

TechniSat HT2 Heating Thermostat 17

OPERATING DEVICE
The LCD shows the configured set point or the valve opening percentage if the device is in manufacturer specific mode.

Set point adjustment
The set point is adjusted via plus and minus button. Altering the set point locally will set the HT 2 in heating mode. The energy saving set point can only be adjusted via Z-Wave. The configurable set point is 8 C to 28 C. If the set point is increased /decreased above/below the set point limits the HT2 will change into boost/off – mode.

Child protection
Press and hold plus and minus button simultaneously for 3 seconds to enable/disable the child protection. If the HT2 is set into the highest protection level it is no longer possible to operate the device locally.

Altering the operating states

Off-Mode
Press minus button until OFF is displayed.
Boost-Mode
Press the boost button. Alternatively press the plus button until ON is displayed.
Heating-Mode
If the operating state is not heating mode, pressing the plus or minus button will bring the device in heating mode.

Window open detection
If the room temperature drops the window open detection will trigger. Heating thermostat HT 2 will change temporarily in off mode for 15 minutes. Window open detection will end automatically after 15 minutes and the previously active operating mode will be restored. Window open detection can also be canceled by a button press. The window open detection is disabled during manufacturer specific mode. The sensitivity of the window open detection can be configured.

Display NodeID
Press and hold the boost button for 3 seconds to display the NodeID.

6 Z-WaveTechniSat HT2 Heating Thermostat 18

*Availability of the Command Class after adding the heating thermostat HT2 to your Z-Wave network.

U Unsecure

  • S0 Z-Wave Security standard S0
  • S2 Z-Wave Security standard S2

Association
Heating thermostat HT2 can only be associated with the Z-Wave controller.TechniSat HT2 Heating Thermostat 19

Basic
Control basic functions of the heating thermostat HT2 via basic command class.TechniSat HT2 Heating Thermostat 20

Configuration
Heating thermostat HT2 can be configured during runtime.TechniSat HT2
Heating Thermostat 21

Multilevel sensor
Heating thermostat measured the room temperature and automatically reports sensor readings to associated devices. Per default the reporting threshold is +/-0.5 C. This parameter can be altered via configuration command class. The measured room temperature can be adjusted with an offset. The heating thermostat HT2 can receive temperature readings from other Z-Wave devices (wall thermostat for example). The external temperature can be used for temperature regulation. This feature has to be anabled via configuration parameter. The HT2 can handle multilevel sensor reports in the following format:

Multilevel Switch
Allows to request the valve opening in percent. 0% represents a fully shut valve. 100% a fully open valve. The valve opening can be reported on change. If the configuration parameter is set. Controlling the valve directly via multilevel switch command class is only possible if the heating thermostat HT2 is in manufacturer specific mode.

Notification
Heating thermostat HT2 will send notifications on certain events.TechniSat
HT2 Heating Thermostat 23

Protection
Heating thermostat HT2 can be locked remotely.TechniSat HT2 Heating
Thermostat 24

Thermostat Mode
Heating thermostat HT2 offers following modes.

Thermostat set point
The following set points of the heating thermostat HT2 can be altered.

TechniSat HT2 Heating Thermostat 26

Troubleshooting

TechniSat HT2 Heating Thermostat
27

Replace batteries
Adjust temperature of the boiler water. Remove the HT2, move the valve back and forth per hand or with a tool Unmount HT2. Move the valve stem several times by hand, it may be that adaption is impossible because your valve is calcified or the seat no longer performs it function. Remove batteries. Out in the pressure piece. Insert the batteries. The endless thread is rotating now and fixes the pressure piece again.

  • Z-wave controller out of range
  • Check if the valve is jammed
  • Check if the HT2 is correctly mounted
  • Check if the HT2 is correctly mounted

Technisat is a registered trademark of: TechniSat Digital GmbH TechniPark.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals