Hantek HDP135V6 0-35V/0-6A Adjustable LED Digital DC Switch Voltage Regulator User Manual
- June 4, 2024
- Hantek
Table of Contents
6A Adjustable LED Digital DC Switch Voltage Regulator
User Manual
Product Introduction
The HDP135V6 power supply is a high-quality, cost-effective power supply. It has a four-digit LED voltage and current display. It also has over-voltage protection (OVP), overcurrent protection (OCP), over-temperature protection (OTP), and USB quick charging functions.
Product Model
Model | CH | Output V/A | LCD | RS232 | AC input |
---|---|---|---|---|---|
HDP135V6 | 1 | 35.2V/6.2A | 4 | None | 15/230VAC |
HDP135V6A | 1 | 35.2V/6.2A | 4 | None | 230VAC |
HDP135V6B | 1 | 35.2V/6.2A | 4 | None | 115VAC |
HDP135V6S | 1 | 35.2V/6.2A | 4 | Yes | 15/230VAC |
Performance Specifications
-
Rated Working Condition
AC input: 115 VAC ± 10%, 230 VAC ± 10%, 50/60Hz
Working Conditions: Temperature -10℃~40℃ Relative humidity ≤80%
Storage Conditions: Temperature -20 ℃~60 ℃ Relative humidity ≤80% -
Specifications
All technical specifications can only be guaranteed when the instrument is operated continuously for more than 30 minutes at the specified operating temperature (18 ℃ to 28 ℃).
Quick Charge
Output Voltage Range| 5V ~ 12V
Output Power| Maximum: 18W
Supported Quick Charging Protocol
| DCP (Apple, Samsung and BC1.2), Qualcomm QC2.0/QC3.0, Huawei Quick Charge
Protocol FCP, Samsung Quick Charge Protocol AFC
General Features
Remote Interface
| RS232 (Optional) Baud rate: 2400
Data bit: 8
Stop bit: 1
No parity check
AC Input| 115 VAC ± 10%, 230 VAC ± 10%,50/60Hz
Working Conditions| Temperature -10 ℃ to 40 ℃
Relative Humidity ≤ 80%
Storage Conditions| Temperature -20 ℃ to 60 ℃
Relative Humidity ≤ 80%
Cooling| Air cooling
Weight| 2.2 Kg
Size| 85 150 230 (mm)
Front Pane
-
Voltage Display
-
Current Display
-
Save and Recall Keys M1 ~ M10
M1 ~ M4: Press [M] once, and the indicator lights up to display the group settings. Use the voltage and current adjustment knobs to adjust the settings that need to be saved, and then long press the [M]key until the indicator lights up, the settings will be saved in the [M*] position. M5 ~ M10: To use M5 ~ M10 to save and recall, use it in conjunction with the [Shift] key.TakingM5 as an example, press the [Shift]key and the [Shift]indicator will light up. Press the [M1]key below M5 once again and the [M1] indicator will light up to display the group settings of M5.Use the voltage and current adjustment knobsto adjust the settings that need to be saved. Press the [Shift]key and the [Shift] indicator will light up. Then long press the [M1]key below M5 until the [M1] indicator lights up and the settings will be saved in the M5 position. -
Shift Key Some keys provide texts above them. This indicates that the key has a function that you can access by pressing and releasing the [Shift] key before pressing this key.For example, if you press and release [Shift] before pressing [M1], you will access
M5 function:
-
ON/OFF: Enables or disables output.
-
Output Terminal Positive output terminal (red): Connect to the positive terminal of the load. The negative output terminal (black): Connect to the negative terminal of the load. Ground terminal (green): Connect to the chassis or ground cable (ground terminal of power cable).
-
USB Quick Charge Port The output voltage of USB quick charge ranges from 5V to 12V, providing a maximum output power of 18 W. The USB quick charge automatically adjusts the output voltage and current according to the identified quick charge protocol. Typical output voltages and currents are 5V@3.4A, 9V@2.0A, and 12V@1.5A. When charging an electronic device that does not have quick charging function, charging will be provided at standard 5V. USB quick charge provides input overvoltage and under-voltage protection, output overcurrent, overvoltage, under voltage, short circuit protection and other functions. The quick charge indicator lights up when the quick charge request voltage is not 5V, that is, it lights up when the request voltage is higher or lower than 5V.
-
Keyboard Lock: Press the key, the indicator will light up, and except this key and [ON/OFF]key,all keys and knobs are disabled. Press the key again and all keys and knobs are restored to use.
-
Current Adjustment Knob Press down the knob to enter the setting mode with the digit flashing. Press the knob several times in succession to change the flashing digit. Turn the knob clockwise to increase the value, and turn the knob counterclockwise to decrease the value.
-
OCP (Over Current Protection) Press the [OCP]key to turn on the OCP function, and the indicator will be on. Press the [OCP]key again to turn off the OCP function, and the indicator will be off. Long press the [OCP]key to enter the setting mode and use the current adjustment knob to change the OCP setting value. When the actual output current is higher than the OCP setting value, the protection function is triggered, the screen displays ” “, and the output is forcibly turned off. However, the [ON/OFF] indicator is not turned off, you can press the [ON/OFF]key to clear the error and turn off the indicator.
-
Voltage Adjustment Knob: The same as the current adjustment knob.
-
OVP (Over Voltage Protection) Press the [OVP]key to turn on the OVP function, and the indicator light will be on. Press the [OVP]key again to turn off the OVP function, and the indicator light will be off. Long press the [OVP]key to enter the setting mode and use the voltage adjustment knob to change the OVP setting value.When the actual output voltage is higher than the setting value, the protection function is triggered, the screen displays “ “, and the output is forcibly turned off, but the [ON/OFF] indicator is not turned off. Press the [ON/OFF]key to clear the error and turn off the indicator.
-
CC (Constant Current Output): In the constant current output state, the CC indicator light is on.
-
Keyboard Lock Sign: Press the keyboard Lock key, the light will be on.In keyboard lock mode, except the Keyboard Lock key and [ON/OFF] key, all keys and knobs are disabled. Press the Keyboard Lock key again and all keys and knobs are restored to use. 1
-
CV (Constant Voltage Output): In the constant voltage output state, the CV indicator light is on.
Rear Panel
![Hantek HDP135V6 0-35V0-6A Adjustable LED Digital DC Switch Voltage Regulator
- Fig4](https://manuals.plus/wp-content/uploads/2022/10/Hantek-HDP135V6-0-35V0 -6A-Adjustable-LED-Digital-DC-Switch-Voltage-Regulator-Fig4.jpg)
Safety Instructions
Check the AC Voltage Gear
The HDP135V6 power supply supports two specifications of AC power
inputs(115VAC or 230VAC). Before use, the user should check the gear of the AC
voltage selector on the rear panel of the power supply, and the input voltage
should be within the range allowed by the gear (±10%). Check the Fuse The
instrument has been installed with a fuse of specified specifications at
delivery. Before use, please check whether the fuse model matches the AC
voltage gear. If the fuse does not match or is blown, replace the fuse
according to the specification. Procedure for replacing a fuse: 1. Turn off
the power supply and remove the power cable.
Take out the fuse holder.
- Remove the fuse and install a new one.
- Take the fuse holder back into the slot.
- Remove the fuse and install a new one.
- Take the fuse holder back into the slot.
Connect the AC Power Supply
Use the power cable provided in the accessories to connect the instrument to
the properly grounded AC power supply. To avoid electric shock, please make
sure that the instrument is properly grounded.
Startup
Press the power switch to start the instrument. The display screen will be
lightened up.
RS232 Remote Control
Only HDP135V6S supports RS232 communication.
To use RS232 for remote control, please log in to the following website to
download:http://hantek.com/products/detail/17189
Or scan the QR code below to enter the website:
http://hantek.com/products/detail/17189
Troubleshooting
- If the AC power supply voltage is normal and the display screen does not light after the startup, it may be a fuse blown or other faults. Turn off the instrument, disconnect the power cable, replace the fuse, or ask a professional for inspection and repair.
- For constant voltage output, if the output voltage is less than the setting value and the CC light is on, which indicates that the instrument is in current protection. It will automatically switches to a constant current output state. At this time, check the load or increase the maximum current according to the use situation.
- For constant current output, if the output current is less than the setting value and the CV light is on, which indicates that the instrument is in open circuit voltage protection. It will automatically switch to a constant voltage output state. At this time, check the load or increase the maximum voltage according to the use situation.
- If the fault persists, please contact Hantek.
IX.Packing List
- One Power Supply
- One Power Cable
- One alligator clip Test Line
- Certificate of Conformity
QingDaoHantek Electronic CO., Ltd.
Address: #35 Building, No. 780 Baoyuan Road,
High-tech Zone, Qingdao City, Shandong Province,
China
Telephone: 0532-55678770
Zip code: 266114
http://www.hantek.com