DiFluid SD101 Omni Professional Roast Particle Analyzer 2 in 1 User Manual

June 2, 2024
DiFluid

DiFluid SD101 Omni Professional Roast Particle Analyzer 2 in 1

Know Your Omni

DiFluid-SD101-Omni-Professional-Roast-Particle-
Analyzer-2-in-1-FIG-1

Product Parameters

Specs

Name Professional Roast / Particle Analyzer (2-in-1)
Model DFT – SD101
Dimensions (Main Unit) 1097972mm(LWH)
Weight (Main Unit) 290g
Screen 2.8-inch HD touchscreen
Battery 2500mAh rechargeable lithium battery
Light Source (Roast Analysis) Multi-band NIR light source (850nm, 940nm)
Optical Sensor Two-dimensional imaging sensor
Data Records 500 Roast Analysis Records / 500 Particle Analysis Records
Operating Temperature 0-45℃
Charging Port USB-C
Charging Parameters 5V   1A

Accessories

  • Omni Main Unit *1
  • Particle Analysis *1
  • Roast Analyzer Tray*1
  • Tray *1
  • Velvet Bag *1
  • Coffee BeanSpoon*1
  • Brush*1
  • Scraper *1
  • Toolbox*1
  • Coffee Ground Spoon*1
  • USB-C Charging Cable *1
  • Calibration Plate *1
  • User Manual、Warranty Card、Test Report*1

Preparation before use

  1. Please ensure that the battery is fully charged. Attach the Omni Main Unit to the Particle Analysis Tray and connect the included charging cable to the USB-C port on the side of the Particle Analysis Tray for charging.
    Note : If you turn on the device during charging, the device will first display the “DiFluid” page, and then enter the charging status page. You need to short-press the button again to enter the “READY” page.

  2. Scan the QR code on the left to download the DiFluid Café App.DiFluid-SD101-Omni-Professional-Roast-Particle-Analyzer-2-in-1-FIG-3

Basic Operation

Operate with Button

  • Power-off State
    Press the button once to start the device. When the screen displays “READY” the device has finished booting up.

  • Power-on State

  • Short click: Perform the test.

  • A short click followed by a long press: Roast degree calibration.

  • Quick double-click: View device information.

  • Long press: Press and hold the button, and the screen will display “Power Off”. Release the button to complete the shutdown operation.

Operate with a touchscreen

DiFluid-SD101-Omni-Professional-Roast-Particle-
Analyzer-2-in-1-FIG-4

Swipe right to access the menu page

  1. Roast: Perform roast analysis.
  2. Particle: Perform particle analysis.
  3. Calibration: Perform the calibration.
  4. Settings: Access more settings for Omni.

Swipe left to access the analysis history page

  1. View Roast Analysis History: Swipe left from the Home Page to view the last roast analysis result, and swipe down to access all roast analysis history.
  2. View Particle Analysis History: Swipe left twice from the Home Page to view the last particle analysis result, and swipe down to access all particle analysis history.

On the Home Page, tap to perform the test. On a sub-page, swipe right to return to the previous level page.

Function operation

Test

There are three methods to start the test

  1. Click the button: In smart test mode, the system will automatically determine whether to perform roast analysis or particle analysis.
  2. Tap the screen on the Home Page : In smart test mode, the system will automatically determine whether to perform roast analysis or particle analysis.
  3. Click the or option on the menu page: The system will directly execute the corresponding analysis.

Roast Analysis

Recommended Procedure

  1. It’s recommended to use the deeper side of Coffee Beans while the Coffee Grounds can use either side of it.
  2. Evenly spread the coffee beans or ground coffee on the Roast Analysis Tray and use the Scraper to make them level with the brim of the tray.
  3. Place the Main Unit over the tray and start the test.
  4. Wait for the test to be completed.

Analysis Result(Table1)DiFluid-SD101-Omni-Professional-Roast-Particle-
Analyzer-2-in-1-FIG-5

Table1

Cautions

  1. Light Source: Roast analysis utilizes near-infrared light sources (850nm, 940nm) for testing and analysis. White light is used for auxiliary functions such as smart tests and silver skin detection.
  2. Silver Skin Detection: You can choose whether to enable the silver skin detection function for coffee beans or coffee grounds in the settings. You can also adjust the sensitivity of it.

Particle Analysis
Recommended Procedure

  1. Take an appropriate amount of coffee powder with a small spoon (refer to sampling recommendations) and place they are located in the central area of the particle analysis tray.
  2. Connect the main unit to the particle analysis tray, making sure that the magnetic connection between the tray and the main unit is properly connected.
  3. Start the test.
  4. Wait for the test to be completed.

Analysis Result(Table2)

DiFluid-SD101-Omni-Professional-Roast-Particle-
Analyzer-2-in-1-FIG-6

Cautions

  1. If the amount of coffee ground taken is more than one flat spoon, the analysis of finer particles may be affected.
  2. After the Smart Diffusor function is turned on, it can automatically conduct diffusion according to the current particle distribution. If the particles have already been evenly distributed, the diffusion will not be carried out again.

Sampling Recommendations

  1. For a coarse grind, please take two-thirds of a spoonful of fine powder.
  2. For a fine grind, please control it to one-third of a spoonful of fine powder.
  3. If the grind cannot be determined, please take half a spoonful of fine powder.
  4. You can adjust the sampling amount according to the actual situation to achieve better dispersion and uniformity.

Roast Degree Calibration

Instructions

  1. Remove the cover on the Roast Degree Calibration Plate first ( Be aware not to scratch the calibration area ).
  2. Place the calibration plate under the Main Unit and make sure the handle is facing the direction of the button.
  3. Enter Calibration Mode and tap to start the calibration.
  4. You can exit calibration mode after calibration success.

![DiFluid SD101 Omni Professional Roast Particle Analyzer 2 in 1 User Manual

Featured Image:

No file chosen

Update Post

Add MediaVisualText

Heading 4

H4

Close dialog

Add media

Actions

Upload filesMedia Library

Filter mediaFilter by type

Uploaded to this post

Filter by date

All dates

Search

Media list

Showing 12 of 12 media items

UPLOADING

10 / 11 – DiFluid-SD101-Omni-Professional-Roast-Particle- Analyzer-2-in-1-FIG-8.PNG

ATTACHMENT DETAILS

DiFluid-SD101-Omni-Professional-Roast-Particle-Analyzer-2-in-1-FIG-7.png

March 28, 2024

25 KB

807 by 372 pixels

Edit Image

Delete permanently

Alt Text

Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title

DiFluid-SD101-Omni-Professional-Roast-Particle-Analyzer-2-in-1-FIG-7

Caption

Description

File URL:

https://manuals.plus/wp-content/uploads/2024/03/DiFluid-SD101-Omni- Professional-Roast-Particle-Analyzer-2-in-1-FIG-7.png

Copy URL to clipboard

ATTACHMENT DISPLAY SETTINGS

Alignment

Center

Link To

None

Size

Full Size – 807 × 372

Selected media actions

1 item selected

Clear Insert into post

No file chosen](https://manuals.plus/wp-content/uploads/2024/03/DiFluid-SD101 -Omni-Professional-Roast-Particle-Analyzer-2-in-1-FIG-7.png)

Settings

DiFluid-SD101-Omni-Professional-Roast-Particle-
Analyzer-2-in-1-FIG-8

On the menu screen, click the option to enter the settings page.

  1. Roast: The settings related to roast analysis.
  2. Particle: The settings related to particle analysis.
  3. General: Device settings like language and screen brightness.
  4. Device Info: See more Omni product information.
  5. Factory Reset: Long-press on the reset icon and wait for the progress bar to complete filling (5 seconds). This will restore the device to its factory settings (Please note: This operation will clear all the history records, reset all settings and reboot the device).

Standards Specifications

Summary of Roast Analysis Standards

AGTRON Values COMMON SCALA

0 ≤ AGTRON ≤ 30

| ****

Espresso Roast

| ****

Very Dark


30 < AGTRON ≤ 40

| ****

French Roast

| ****

Dark


40 < AGTRON ≤ 50

| ****

Full City Roast

| ****

Medium-Dark


50 < AGTRON ≤ 60

| ****

City Roast

| ****

Medium


60 < AGTRON ≤ 70

| ****

Dark Roast

| ****

Medium-Light


70 < AGTRON ≤ 80

| ****

Medium Roast

| ****

Light


80 < AGTRON ≤ 90

| ****

Cinnamon Roast

| ****

Very Light


90 < AGTRON ≤ 150

| ****

Light Roast

| ****

Extra Light

International Standard ISO Sieve Pore Size ( μm )| ****

American Society for Testing and Materials Sieve Specifications (ASTM)

| ****

American Sieve Society

Sieve Specification (TYLER)

---|---|---


300

| ****

50

| ****

48


425

| ****

40

| ****

35


600

| ****

30

| ****

28


850

| ****

20

| ****

20


1180

| ****

16

| ****

14


1400

| ****

14

| ****

12


1700

| ****

12

| ****

10


2360

| ****

8

| ****

8

Grind Size Standard

Particle Size( μm ) Grind Size

100 ≤ Particle Size < 500

| ****

Fine


500 ≤ Particle Size < 800

| ****

Medium Fine


800 ≤ Particle Size < 1100

| ****

Medium


1100 ≤ Particle Size < 1400

| ****

Medium Coarse


1400 ≤ Particle Size ≤ 2500

| ****

Coarse

FCC STATEMENT

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE : The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. The SAR limit of USA (FCC) is 1.6 W/kg averaging over one gram of tissue. Device types DFT-SD101(FCC ID: 2A26IDFT-SD101) have also been tested against this SAR limit.

CONTACT

  • Shenzhen Digitizing Fluid Technology Co., Ltd.
  • Add: Room 1602, Jinhua Building, Longhua District, Shenzhen, China.
  • Tel: (+86) 0755-23761557
  • Web : www.digitizefluid.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals