Renowatt VT-5139 v2 Inverter 5.12KWh 48V 100Ah Instruction Manual

June 2, 2024
Renowatt

Renowatt-LOGO

Renowatt VT-5139 v2 Inverter 5.12KWh 48V 100Ah

Renowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-PRODUCT

Product Information

Specifications

  • Battery Type: LFP
  • Rated Capacity of Battery Pack: 100Ah
  • Rated Voltage of Battery Pack: 51.2V
  • Maximum Charging Voltage: 57.6V
  • Minimum Discharge Voltage: 40V
  • Rated Charge/Discharge Current: 100A
  • Maximum Charge/Discharge Current: 120A
  • Charging Temperature Range:
  • Discharge Temperature Range:
  • Depth of Discharge: 80%
  • Discharge Magnification: 1C
  • Cycle Life: 5000 times0.5C
  • Interactive Mode (APP):
  • LCD+Button +Bluetooth
  • Dimension Weight: About 65KG

Product Usage Instructions

Installation

  1. Refer to the figure below to install the battery module.
  2. The fixing feet should be on the ground, and the module body is fixed on the wall using 4~6mm combination screws.
  3. The reference tightening torque is 35 N.m.
  4. Check whether the battery module is firm and safe. Avoid damp, rain, and direct sunlight as much as possible.

App Installation

  1. Scan the given QR code to download the App and install it.
  2. After the installation is complete, open the phone settings application settings authorization management, and authorize Bluetooth and positioning for this App.
  3. For Android: Open the software and click BLE to connect to Bluetooth.
  4. For iOS: Click Scan Devices to scan the machine, find the device starting with AT, and click Connect to connect.

Frequently Asked Questions (FAQ)

How do I access the user manual in multiple languages?

  • You can scan the QR code provided in the manual to access the manual in multiple languages.

What should I do in case of any query or issue with the product?

  • If you have any queries or issues with the product, please reach out to us at support@v-tac.eu for assistance.

What precautions should I take during installation?

  • Make sure to turn off the power before starting the installation, and ensure that the installation is performed by a qualified electrician.

TECHNICAL DATA

Battery type LFP
Rated capacity of battery pack 100Ah
Rated voltage of battery pack 51.2V
Maximum charging voltage 57.6V
Minimum discharge voltage 40V
Rated charge/discharge current 100A
Maximum charge/discharge current 120A
Charging temperature range 0 to +45°C
Discharge temperature range -20°C to +50°C
Depth of discharge >80%
Discharge magnification <1C
Self-discharge (25°C) <3%/Month
Cycle life >5000 times(<0.5C )
Interactive mode (APP) LCD+Button+Bluetooth
Dimension 700515250mm (Error±2mm)
Weight About 65KG

INTRODUCTION

  • Thank you for selecting and buying V-TAC Products. V-TAC will serve you the best. Please read these instructions carefully & keep this user manual handy for future reference.
  • If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at your best.

Multi-Language Manual QR CODE

Please scan the QR code to access the manual in multiple languages.

WARNING

  1. Please make sure to turn off the power before starting the installation.
  2. Installation must be performed by a qualified electrician.
  • This marking indicates that this product should not be disposed of with other household wastes.
  • Caution, risk of electric shock.

CONTROL PANEL

Renowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-FIG-2

HUMAN-COMPUTER INTERACTION CONTENT

Project Function Remark
Button POWER When Powered on:

1. Short press: invalid

2. Long press (press for 4~6 seconds and release): power off

When powered off:

1. Short press: invalid

2. Long press (press for 4~6 seconds and release ): turn on

UP| Page up
DOWN| Page down
Switch| DC OUTPUT| Use the key to open the front panel before switching on and off

HUMAN-COMPUTER INTERACTION CONTENT

Project Function
LCD There are 6 display interfaces in total:

1.  Main interface information (voltage/current/SOC/status code);

2.  Secondary main interface information (maximum and minimum cell voltage/maximum and minimum temperature);

3.  Display 1~4cell voltage;

4.  Display 5~8cell voltage;

5.  Display 9~12cell voltage;

Error code| E11: Level 1 alarm of module equipment failure
E12: Module equipment failure secondary alarm
E21: Level 1 alarm of module communication abnormality
E22: Module communication abnormality secondary alarm
E31: Module address is abnormal level 1 alarm
E32: Module Address Abnormal Level 2 Alarm
E41: Module balancing abnormal level 1 alarm
E42: Module balance abnormal secondary alarm
E51: Module total voltage overvoltage level 1 alarm
E52: Module total voltage overvoltage secondary alarm
E61: Level 1 alarm of module total voltage undervoltage
E62: Second-level alarm of module total voltage undervoltage
E71: Module charging over current level 1 alarm
E72: Module charging over the current secondary alarm
E81: Module discharge overcurrent level 1 alarm
E82: Module discharge overcurrent secondary alarm
E83: Module discharge load short circuit (serious)
E91: Single battery overvoltage level 1 alarm
E92: Single battery overvoltage secondary alarm
E101: Single battery undervoltage level 1 alarm
E102: Single battery undervoltage secondary alarm
E111: Module battery high-temperature level 1 alarm
E112: Module battery high-temperature secondary alarm
E121: Module battery low-temperature level 1 alarm
E122: Module battery low-temperature secondary alarm

INTERFACE DEFINITION

Renowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-FIG-3

Port Port type NO Signal name Remark
Battery interface BAT 1 BAT+ Battery-positive output interface
2 BAT- Battery negative output interface
Battery output switch Battery Battery Battery output switch (control

positive)

INSTALLATION

  1. Refer to the figure below to install the battery module, the fixing feet are on the ground, the module body is fixed on the wall, and the screws are 4~6mm combination screws. The reference tightening torque is 35 N.m. (unit mm)Renowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-FIG-4
  2. Check whether the battery module is firm and safe. (Avoid damp, rain, and direct sunlight as much as possible)

APP INSTALLATION

  1. Step 1: Scan the given QR code to download the app, then install the app.
  2. Step 2: After the installation is complete, open the phone settings – application settings authorization management, and authorize the Bluetooth and positioning of this APP.
  3. Step 3: Open the software and click BLE” to connect to BluetoothRenowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-FIG-6
  4. Step 4: Click “Scan Devices” to scan the machine, find the device starting with “AT” and Click “connect” to connect.
  5. Step   5: After successfully pairing the device with the app, you can start reading the relevant data, including “CONNECTION, DEVICE INFO, LIVE DATA, HISTORY INFO, WARNING INFO, CONTACT” to switch (See the below pic).Renowatt-VT-5139-v2-Inverter-5-12KWh-48V-100Ah-FIG-9
  • IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU.
  • FOR MORE PRODUCT RANGES, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD.
  • BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals