KNX MDT SCN-RTC20.02 Time Switch Instruction Manual

June 4, 2024
KNX

MDT Logo SCN-RTC20.02 Time Switch
Instruction Manual

Important safety notes

Danger High Voltage
Installation and commissioning of the device only be carried out by authorized electricians. The relevant standards, directives, regulations, and instructions must be observed. The devices are approved for use in the EU and have the CE mark. Use in USA and Canada is prohibited.

Terminals, Operating, and Display Time Switch

KNX MDT SCN RTC20.02 Time Switch - Fig 1

  1. KNX bus connection terminal
  2. Programming key
  3. Red programming LED
  4. Operating buttons

Installation Time Switch

Technical Data SCN-RTC20.02
Number of channels 20
Cycle times each channel 8
Accuracy typ. < 5min/year
Power reserve 24 hours
Specification KNX interface TP-256
Available application software ETS 5

Permitted wire gauge
KNX bus connection terminal| 0,8mm Ø, solid core
Power Supply| KNX Bus
Power consumption KNX bus type.| < 0,25W
Operation temperature range| 0 bis + 45°C
Enclosure| IP 20
Dimensions MDRC (Space Units)| 4TE

  1. Place the Time Switch on DIN 35mm rail.
  2. Connect the Time Switch to the KNX bus.
  3. Switch on the KNX power supply.

Exemplary circuit diagram SCN-RTC20.02

KNX MDT SCN RTC20.02 Time Switch - Fig 2

Description Time Switch

The MDT Time switch with 20 channels (8 cycle times for each channel) has a daily/weekly/Astro switching function and an adequate power reserve if the bus voltage fails. The cycle times of the single channels are adjustable by the ETS or can be set directly at the device.
The large active color display for comfortable handling allows direct switching of the 20 channels (Manual Mode).
The time switch offers cyclic sending of the time on the KNX bus and clock time adjustment by bus telegram (Master-/slave mode).
The 8 logical blocks with 4 inputs each allow individual conjunctions.
The MDT Time Switch is a modular installation device for fixed installation in dry rooms. It fits on DIN 35mm rails in power distribution boards or closed compact boxes.
Commissioning Time Switch
Note: Before commissioning please download the application software at www.mdt.de/Downloads.html

  1. Assign the physical address and set parameters with the ETS.

  2. Upload the physical address and parameters into the Time Switch.
    After the request press the programming button.

  3. After successful programming, the LED turns off.