MEASURE WITH INTELLIGENCE! OPERATION MANUAL
Intended Use
The ecom-UNO is suitable for measuring the positive, negative and differential pressure of gases. It is particularly suitable for work on heating, ventilation and air conditioning systems. The measuring range covers pressures from -200 hPa to +200 hPa.
Scope of Delivery
- ecom-UNO 200 hPa
- 2x 1.5 V AA Batteries
- Protective bag (option)
General Safety Instructions
WARNING
Magnetic Field
The magnetic field can cause pacemakers to malfunction in their impair.
Operation of the ecom-UNO by persons with pacemakers is prohibited.
WARNING
Hazard of Injury
Improper work on incinerators can cause injuries.
Work on incinerators may only be done by qualified specialists.
CAUTION
Damage to the Sensor
Pressures greater than specified will destroy the sensor.
Do not use ecom-UNO to measure higher pressures.
CAUTION
Damage of the Electricity
Moisture or frost can damage the electronics.
Do not store the unit in moist rooms or at sub-zero temperatures.
CAUTION
Damage of the Sensors
Substances containing solvents damage the device’s sensors.
Avoid contact with substances containing solvents.
Device Description
1 | Connection Overpressure | 4 | Battery Capacity | 7 | HOLD Key |
---|---|---|---|---|---|
2 | Connection Depression | 5 | Cursor | 8 | Setting Key |
3 | Display | 6 | Pressure Units | 9 | ON/OFF |
Magnetic Holder
The ecom-UNO has a magnetic holder on the back, with which the device can be
attached to most metal surfaces.
WARNING
Magnetic Field
The magnetic field can cause pacemakers to malfunction in their impair.
Operation of the ecom-UNO by persons with pacemakers is prohibited.
Initiation/Measurement
- Connect the hoses.
- Switch on the device.
NOTICE
ecom-UNO carries out a segment test when switched on.
It starts in the lower measuring range and is ready to measure after 3
s.
Operations
Automatic Switch-off
- ecom-UNO switches off after 5 min, with values ≤ 0.01 hPa/mbar.
- ecom-UNO switches off after 15 min, for values > 0.01 hPa/mbar.
Display Damping
- The display damping can be set from 1 (weak damping) to 9 (strong damping) (see setup).
Zero Point Correction
- The zero point correction is used to compensate the zero point drift after switching on the instrument (see setup).
Range Switch
- If the pressure of 0.5 hPa/mbar is exceeded, the ecom-UNO automatically switches to the higher measuring range.
- Resolution from 0.001hPa/mbar to 0.01 hPa/mbar and from 0.01 hPa/mbar to 0.1 hPa/mbar.
Range Overload
- If the measuring range of -200 hPa to +200 hPa is exceeded 4 lines appear on the display.
Set Zero Point
- Press the setting key.
Unit Switch
- Hold down the setting key.
- The cursor for the set printing unit moves from unit to unity.
- Release the setting key at the desired unit.
Scan of the Maximum and Minimum Value
-
Press the HOLD key.
• Measured values are “frozen” and the value at the time the key is pressed is displayed. -
Press the HOLD key twice.
• Minimum value, smallest value since switching on the device, is displayed. -
Press the HOLD key 3 times.
• Maximum value, the highest value since the device was switched on, is displayed. -
Press the HOLD key 4 times.
• ecom-UNO is in measuring mode again. -
Hold the HOLD key.
• Minimum and maximum values are deleted.
Change Batteries
NOTICE
The two 1.5 V AA batteries must be replaced when the battery capacity
indicator flashes.
- Open the lid of the battery compartment.
- Remove used batteries.
- Replace batteries with new batteries.
- Slide the cover onto the battery compartment.
Setup
Settings can be made in the setup menu. To do this, press the ON/OFF key for
about 3 seconds after switching on the unit.
The following functions can be set:
Number | Value | Function | Factory Setting |
---|---|---|---|
0 | 0 – 1 | 1 = Set to Factory Setting | 0 |
1 | 0 – 90 | Automatic Switch-off | 15 |
2 | 1 – 9 | Display Damping | 3 |
3 | 0 – 1 | 1 = with Zero Correction | 1 |
- Select a function with the ON/OFF key.
- Setting is made with the HOLD and the setting key.
- Press and hold the ON/OFF key for about 3 seconds to exit the setup menu.
Technical Data
Technical Data|
---|---
Measurement range| 200 hPa
Resolution| 0,01 hPa
Overload| 300 hPa °C
Accuracy| 1 % of the MBE
Ambient Temperature| 0°C-40°C
Storage Temperature| -20 °C – 70 °C
Batteries| 2 x 1,5 V AA
Power Consumption| 20 mA
Size| 106 mm x 64 mm x 28 mm
Weight| 150 g
NOTICE
Subject to technical changes! (Status 01.2023)
Maintenance
To ensure the accuracy of your measuring device, we recommend an annual inspection by an authorised ecom partner. In case of heavy use, shorter inspection intervals should be chosen – please contact your ecom partner.
Disposal
- **** Dispose of used batteries at the designated collection points.
- Dispose of packaging material in an environmentally friendly manner.
- Old devices must be disposed of in an environmentally friendly manner by an authorised centre.
NOTICE
On request we take back old appliances and dispose of them in an
environmentally friendly way.
EC Daclaration of Conformity
The manufacturer
ecom GmbH
Am GroBen Teich 2
D-58640 Iserloha, Germany
hereby declares under its sole responsibility, that the products
pressure measurement devices
Type: ecom-UNO
ecom-DP
ecom-DP Engine
ecom-DP3
comply with the following European Directives:
2014/30/EU EMV-Richtlinie / EMC Directive
2011/65/EU RoHS
The following standard’s were used:
EN 61000-6-2:2005/AC:2005 | EMC — Immunity for industrial environments |
---|---|
EN 61000-6-3:2007/A 1:2011 | EMC – Emission standard for residential, |
commercial and lightindustrial environments
EN IEC 63000:2018| Technical documemation for thf assessment of electrical and
electronic products with respect to the restriction of hezardous substances
Iserlohn, 25.07.2022
Declaration of Conformity
The manufacturer
ecom GmbH
Am Grofen Teich 2
D-58640 Iserlohn, Germany
hereby declares under its sole responsibility, that the products
Pressure measurement devices
Type: ecom-UNO
ecom-DP
ecom-DP Engine
ecom-DP3
are in conformity with the relevant statutory requirements of the following
enactments:
Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012 (RoHS)
The following designated standards were used:
EN 61000-6-2:2005/AC:2005 | EMC – Immunity for industrial environments |
---|---|
EN 61000-6-3:2007/A 1:2011 | EMC – Emission standard for residential, |
commercial and light industrial environments
EN IEC 63000:2018| Technical documemation for thf assessment of electrical and
electronic products with respect to the restriction of hezardous substances
Iserlohn, 12.10.2022
ecom GmbH
Am GroBen Teich 2
D-58640 Iserlohn
Info@ecom.de
www.ecom.de
Phone: +49 2371 945-5
Fax: +49 2371 40305
UK importer:
DRM Technic Ltd.
Unit 25 Raleigh Hall Industrial Estate, Stafford, Staffordshire, ST21 6JL,
UK
sales@drmtechnic.com
www.drmtechnic.com
Phone: +44 (0) 1785 556 593
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>