- Safety precautions:
- Faults and damage:
- Certification:
- Specific conditions of use (X-conditions):
- Safety instructions:
- Entity parameter USB-C interface for use in hazardous locations
- Entity parameter Audio Jack for use in hazardous locations
- Spare parts user replacement in ordinary locations
- Non-Electrical accessories:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ex-Safety Manual
ATEX / IECEx / UKEX
Intrinsically Safe
5G Smartphone
Smart-Ex 03
DZ1
Smart-Ex 03 DZ1 5G Smart Phone
Note:
The current operating instructions, EU Declaration of Conformity and the
Certificate of Conformity can be downloaded from the relevant product page at
www.pepperl-fuchs.com, or alternatively they
can be requested directly from the manufacturer.
Safety precautions:
These safety instructions contain information and safety regulations which are to be observed. Non-observance of this information and these instructions can have serious consequences and may violate regulations. Please read these safety instructions carefully before using the device for the first time! In the event of conflicting information the details specified in the Ex-safety manual shall take precedence. In case of any doubt (in the form of translation or printing errors) the English text shall be applied.
Faults and damage:
If there is any reason to suspect that the safety of the device has been impaired, it must be withdrawn from use and removed immediately from the hazardous area. Measures must be taken to prevent it from being used within the hazardous area accidentally. The safety of the device maybe compromised, if for example:
- There is visible damage on the housing.
- Malfunctions occur.
- The device has been improperly stored.
- Device markings or inscriptions are illegible.
- Permitted limit values have been exceeded.
Certification:
ATEX/UKCA-Marking: | II 2 GD |
---|---|
Ex-Marking gas: | Ex ia IIC T4 Gb |
Ex-Marking dust: | Ex ia IIIC T135°C Db |
IECEx Certificate no.: | IECEx EPS 23.0021X |
ATEX Certificate no.: | EPS 23 ATEX 1 094 X |
UKEX Certificate no.: | EPS 23 UKEX 1 095 X |
Ambient Temperature: | -20°C ≤ Ta ≤ +60°C |
The Ex specified ingress protection level of IP64 differs to the specified industrial IP-rating due to the increased enclosure tests required under IEC 60079-0 in conjunction with the tests listed in IEC 60529.
Warnings:
- USE ONLY BATTERY PACK TYPE EX-BP S03 OR EX-BP S03s
- DO NOT OPEN THE DEVICE IN A HAZARDOUS LOCATION
- DO NOT CHARGE THE BATTERY IN A HAZARDOUS LOCATION
Specific conditions of use (X-conditions):
The device shall be protected against high energy impacts.
When used in group IIC or IIB environments the device shall not be used in
close proximity to processes producing high electrostatic charges.
Safety instructions:
Charging, SIM-card and battery pack replacement is only allowed in ordinary
(non-hazardous) locations. It must be ensured that the battery cover is
mounted properly before entering the hazardous location so that the IP rating
of the device is not affected.
The device may only be charged in a temperature range of 0 °C to 45 °C.
Charging and wired data-transfer via the USB-C interface is limited to a
maximum Um of 6V and a current of 10A (Im).
It must be ensured that the power plug/supply used for charging and wired data
connections via the USB-C port is a non-shock hazard extra low voltage
equipment such as SELV, PELV or ES1 as per IEC 62368-1 (former IEC 60950-1) or
equivalent.
Intrinsically safe equipment for use in the hazardous location connected to
the audio jack or USB-C interface must fulfill one of the following:
- The combination of the intrinsically safe equipment and the Smart-Ex 03 DZ1 must be assessed and the certificate of the equipment must allow the connection to the Smart-Ex 03.
- The equipment entity parameter must match with the Smart-Ex 03 DZ1 entity parameter as follows:
Entity parameter USB-C interface for use in hazardous locations
Uo = 4.2 V / Io = 0.8 A / Po = 0.6 W / Co = 2 μF / Lo = 8 μH
Ui = 4.4 V / Ii = 1.5 A / Pi = NR / Ci = 15 μF / Li = 2 μH
Entity parameter Audio Jack for use in hazardous locations
Uo = 3.6 V / Io = 290 mA / Po = 210 mW / Co = 2.6 μF / Lo = 730 μH
Ui = 4.5 V / Ii = 30 mA / Pi = NR / Ci = 0 μF / Li = 0 μH
Spare parts user replacement in ordinary locations
The following spare parts are allowed to be replaced by the end user in
ordinary non-hazardous locations:
a) USB-C Cover
b) Audio Jack door
c) Battery Cover / Battery pack
Repair:
Repairs are to be conducted by the manufacturer or an authorized service
center.
Non-Electrical accessories:
The following accessories are allowed to be used together with the SmartEx 03 in the hazardous location. The accessories groups and EPL must be considered together with the groups and EPL of the Smart-Ex 03 model used. The worst case of both must be assumed.
Accessory| Description| Suitable for Group and EPL|
Restriction
---|---|---|---
CR-Ex S03| Cradle with belt- or spring clip| Groups I, IIC, IIIC EPL Ma, Ga,
Da| None
LC-Ex S03| Leather case with belt- or spring clip| Groups I, IIC, IIICEPL Ma,
Ga,Da| In IIC environments no use next to strong charge producing mechanisms
LH-Ex S03| Leather holster| Groups I, IIC, IIIC
EPL Ma, Ga, Da| None
RL ID01| Retractable lanyard| Groups I, IIC, IIIC
EPL Ma, Ga, Da| None
EXT-C2LCO I L| Coil tether| Groups I, IIC, IIIC
EPL Ma, Ga, Da| None
Mini QD Loop| Mini disconnect clip with loop| Groups I, IIC, IIIC
EPL Ma, Ga, Da| None
ST 02 with tether| Stylus pen with tether| Groups I, IIC, IIIC
EPL Ma, Gb, Da| None
© 2023 Pepperl+Fuchs SE
The contents of this document, either in part or in their entirety, may not be
reproduced, forwarded, distributed or saved in any way without Pepperl+Fuchs
SE prior written consent. The contents of this document are presented as they
currently exist. Pepperl+Fuchs SE does not provide any express or tacit
guarantee for the correctness or completeness of the contents of this
document, including, but not restricted to, the tacit guarantee of market
suitability or fitness for a specific purpose unless applicable laws or court
decisions make liability mandatory. Pepperl+Fuchs SE reserves the right to
make changes to this document or to withdraw it any time without prior notice.
www.pepperl-fuchs.com
Subject to modifications · © Pepperl+Fuchs
Printed in Germany · MAS-0228B | 03/2024
WEEE-Reg.-Nr. DE 934 99306 · public
Pepperl+Fuchs Quality
Download our latest policy here:
www.pepperl-fuchs.com/quality
References
- Global lubrication solutions | FUCHS Group | Fuchs SE
- Pepperl+Fuchs International. Industrial Sensors, Factory Automation, Process Automation, Intrinsic Safety, Explosion Protection
- Pepperl+Fuchs International. Industrial Sensors, Factory Automation, Process Automation, Intrinsic Safety, Explosion Protection
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>