ecom LSG-CO Leakage Detection Instruction Manual

May 15, 2024
ECOM

ecom LSG-CO Leakage Detection

Product Information

Specifications

  • Intended Use: Leak detection device
  • Scope of Delivery: Device, batteries, user manual

Product Usage Instructions

General Safety Instructions

  • Before using the device, carefully read and follow all safety instructions provided in the user manual.

Device Description

  • The leak detection device is designed to detect leaks in various settings. It is compact and easy to use.

Initiation

  • Follow the initiation steps outlined in the user manual to activate the device for use.

Leak Detection

  • Place the device in the area where you suspect a leak and observe the readings on the display.

Adjustments

  • Refer to the user manual for instructions on making adjustments to settings based on your requirements.

Reset Zero Point

  • If needed, reset the zero point of the device following the guidelines provided in the manual.

Switch-off Power Supply

  • When not in use, switch off the power supply to conserve battery life.

Change Batteries

  • When the batteries are low, replace them with new ones according to the instructions in the manual.

Error Meaning

  • If you encounter an error message on the device, refer to the manual for the meaning of the error code.

Action

  • Follow the recommended actions provided in the manual to address the error and resume normal operation.

Technical Data

  • For detailed technical specifications, refer to the technical data section in the user manual.

Maintenance and Disposal

  • Follow the maintenance guidelines provided in the manual to ensure optimal performance.
  • When disposing of the device, follow local regulations for proper disposal methods.

Intended Use

  • The gas detector com-LSG-CO is designed to detect gas leaks in engines and their exhaust system.
  • The instrument displays existing carbon monoxide concentrations and warns, if an alarm threshold of 1600 ppm CO is exceeded, by an acoustic signal.
  • The sensor head is connected to a flexible gooseneck so that even the most difficult parts of the system can be achieved.

Scope of Delivery

  • ecom-LSG-CO
    • 2x 1,5 V AA Batteries

General safety instructions

WARNING Hazard of Injury

  • Improper work on incinerators can cause injuries.
  • Work on incinerators may only be done by qualified specialists.

WARNING Risk of poisoning

  • High CO concentrations can be life-threatening. The ecom-LSG-CO is not suitable as personal protective equipment.
  • NOTE Do not switch on the ecom-LSG-CO in gas-laden air, as this will lead to incorrect measurement results!

Device Description

ecom-LSG-CO-Leakage-Detection-fig-1

  1. Flexible Tube
  2. Display
  3. HOLD Key
  4. ON/OFF
  5. LED Warning Light
  6. Contact Pins
  7. Headphone Connection
  8. Senso Head
  9. Headphone (Option)

Initiation

  • Turn the ecom-LSG-CO in CO free air on by pressing the button <l/O>. The display shows the version number and the sensor is set to 0.

Leak Detection

  • NOTE The sensor reacts cross-sensitive to hydrogen (100 ppm H2 appears as 40 ppm CO)!
  • Move the sensor head slowly along the components to be tested. As soon as the instrument approaches a leak, the measured value display reacts with increasing values (when CO is in the flue gas).
  • By pressing the key, the highest measured value since switching on the instrument is displayed (the value flashes – back to the actual measured value by pressing the key again).
  • If a concentration of 1600 ppm CO is exceeded, the instrument warns with the LED warning light and an audible signal (can be disabled). Optionally, if required (strong ambient noise) headphones (in the ear) are connectable to the com-LSG-CO (headphone jack). Please use only the headphones supplied by com.
  • CAUTION Damage to the device Never connect other components than the ecom headphones – the device can be damaged!

Adjustments

  • If the <ON/OFF> key is pressed when the instrument is in use, the lighting can be switched on and off with the key (LI 0 = off / LI | = on).
  • After the <ON/OFF> key is pressed again the acoustic signal can be switched on and off with the key (SO 0 = off / SO | = on).
  • After adjustment switch back to the measurement with < ON/OFF> key.

Reset Zero Point

  • Set the zero point only in clean air again! For this purpose, the key must be pressed until the measured value is 0.

Switch-off

  • Keep the <ON/OFF> key pressed until the value in the display is gone.

Power Supply

  • The ecom-LSG-CO is delivered with two batteries 1,5 V AAA (Micro).
  • Alternatively, the battery type 1,2 V AAA NiMh (Nickel-Metall-Hydride) can be used.
  • Low batteries are indicated by „bAtt” in the display (capacity for approx. 1 h).
  • If the voltage drops further, “bAtt” appears more than once in the display and the ecom-LSG-CO switches off automatically.

NOTE

  • Remove batteries if not in use!

Change Batteries

  • Open the battery compartment located on the back of the instrument and exchange the batteries (respect polarity / do not short-circuit).

FAQ

The following error messages may occur:ecom-LSG-CO-Leakage-Detection-
fig-2

Technical Data

ecom-LSG-CO-Leakage-Detection-fig-3

  • NOTE Subject to technical changes! (Status 01.2023)

Maintenance

  • To ensure the accuracy of your measuring device, we recommend an annual inspection by an authorized ecom partner.
  • In case of heavy use, shorter inspection intervals should be chosen – please contact your com partner.

Disposal

  • Dispose of used batteries at the designated collection points.
  • Dispose of packaging material in an environmentally friendly manner.
  • Old devices must be disposed of in an environmentally friendly manner by an authorized center.

NOTE

  • On request, we take back old appliances and dispose of them in an environmentally friendly way.

EC Declaration of Conformityecom-LSG-CO-Leakage-Detection-
fig-4

Declaration of Conformity

ecom-LSG-CO-Leakage-Detection-fig-5

INTELLIGENT MESSEN! MEASURE WITH INTELLIGENCE!

Documents / Resources

| ecom LSG-CO Leakage Detection [pdf] Instruction Manual
LSG-CO Leakage Detection, LSG-CO, Leakage Detection, Detection
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ECOM User Manuals

Related Manuals