Product Specifications

Legend

PROS-00-Hunter-Spray-Body-1

  1. HUNTER SPRAY BODY (PROS-00)Nozzle and cap per plan.
  2. FIELD BUILT SWING ARM Per installing contractor.
  3. FINISHED GRADE
  4. ADJACENT LANDSCAPE
  5. LATERAL FITTING PER PLAN
  6. HUNTER CHECK VALVE (HCV) Per plan.
  7. HUNTER STAKING KIT
  8. 1/2″ [13MM] REBAR

Minimum 18″ [45CM] unless noted otherwise (U.N.O.).

Description of Diagram

The diagram illustrates the installation of a shrub adapter (PROS-00) at grade level, which includes a swivel riser, a check valve, and an on-grade lateral. It is a schematic representation using symbols and lines to depict the components and their placement relative to the finished grade and adjacent landscape. A Hunter spray body with a nozzle and cap is indicated at the top of the setup, followed by a field-built swing arm, a lateral fitting according to the plan, and a Hunter check valve. The setup is secured with a Hunter staking kit and supported by a 1/2″ [13MM] rebar with a minimum length of 18″ [45CM] unless otherwise noted. The diagram is not to scale (N.T.S.).

Specifications

Component Description Notes
Hunter Spray Body (PROS-00) Nozzle and cap assembly As per design plan
Field Built Swing Arm Custom swing arm Installed by the contractor
Finished Grade Surface level of the ground
Adjacent Landscape Surrounding vegetation or ground cover
Lateral Fitting Pipeline connection As per design plan
Hunter Check Valve (HCV) Valve to prevent backflow As per design plan
Hunter Staking Kit Support and stability for the system
1/2″ [13MM] Rebar Steel reinforcing bar Minimum length of 18″ [45CM] U.N.O.

For additional resources and information, please visit Hunter Irrigation Sprinkler Systems | Hunter Industries.

  • 1. Hunter Spray Body (PROS-00): Nozzle and Cap per plan
  • 2. Field Built Swing Arm (Per Installing Contractor)
  • 3. Finished Grade
  • 4. Adjacent Landscape
  • 5. Lateral Fitting per plan: Refer to plan min. 12″ [30cm] U.N.O.
  • 6. Hunter Check Valve (HCV per plan)
  • 7. Hunter Staking Kit
  • 8. 1/2″ [13mm] Rebar min. 18″ [45cm] U.N.O.

Product Usage Instructions

  1. Hunter Spray Body Installation: Install the spray body with the provided nozzle and cap according to the plan.
  2. Field Built Swing Arm: Assemble the swing arm as directed by the installing contractor.
  3. Lateral Fitting Placement: Ensure lateral fittings are positioned according to the plan, with a minimum distance of 12″ [30cm] from other components.
  4. Hunter Check Valve Installation: Install the check valve as per the plan specifications.
  5. Staking Kit Usage: Utilize the staking kit to secure components in place.
  6. Rebar Installation: Place the 1/2″ [13mm] rebar at a minimum depth of 18″ [45cm] U.N.O. for stability.

RUB ADAPTER (PROS-00) AT GRADE WITH SWIVEL RISER, CHECK VALVE, AND ON-GRADE LATERAL

Frequently Asked Questions (FAQ)

Q: Where can I find more detailed installation instructions?
A: For detailed installation instructions, please refer to the user manual provided with the product or visit our website at www.hunterindustries.com.

Where can I find more information about Hunter Irrigation Sprinkler Systems?
More information about Hunter Irrigation Sprinkler Systems can be found on their official website at www.hunterindustries.com.

What is the purpose of the Hunter Staking Kit?

The Hunter Staking Kit is used to provide support and stability to the sprinkler system components above the ground.

What does 'U.N.O.' stand for in the context of the diagram?

'U.N.O.' stands for 'Unless Noted Otherwise' and is used to indicate that the length of the rebar should be a minimum of 18

Is the diagram to scale?

No, the diagram is not to scale N.T.S., which means it is a symbolic representation and not an exact depiction of the component sizes or distances between them.

Can I use the product without the swing arm?

The swing arm is an essential component for proper functioning. It is recommended to install it as per the instructions provided.

www.hunterindustries.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals