HARVIA PC70XE Electric Sauna Heater Instruction Manual
- May 15, 2024
- HARVIA
Table of Contents
PC70XE Electric Sauna Heater
Instruction Manual PC70XE, PC70XW
PC90XE, PC90XW
PC70XE Electric Sauna Heater
Instructions for Installation and Use of Electric Sauna Heater
|
---|---
https://mediabank.harvia.com/catalog/Harvia/r/284
|
<https://mediabank.harvia.com/catalog/Harvia/r/2778>
These instructions for installation and use are intended for the owner or the
person in charge of the sauna, as well as for the electrician in charge of the
electrical installation of the heater. After completing the installation, the
person in charge of the installation should give these instructions to the
owner of the sauna or to the person in charge of its operation. Please read
the instructions for use carefully before using the heater.
The heater is designed for the heating of a sauna room to bathing temperature.
It is not to be used for any other purpose.
Congratulations on your choice!
Guarantee:
- The guarantee period for heaters and control equipment used in saunas by families is two (2) years.
- The guarantee period for heaters and control equipment used in saunas by building residents is one (1) year.
- The guarantee does not cover any faults resulting from failure to comply with installation, use or maintenance instructions.
- The guarantee does not cover any faults resulting from the use of stones not recommended by the heater manufacturer.
INSTRUCTIONS FOR USE
1.1. Piling of the Sauna Stones
The piling of the sauna stones has a great effect on both the safety and the
heating capability of the heater.
Sauna heater stones are significant in terms of the unit’s safety. In order
for the warranty to remain valid, the user is responsible for proper
maintenance of the stone space in accordance with the specifications and
instructions.
Important information on suitable sauna stones:
- Suitable sauna stone materials are peridotite, olivine diabase, olivine and vulcanite.
- Only use cleavage surface and/or rounded stones for your sauna heater.
- If the heating elements of an electric sauna heater are in contact with the stones, rounded stones may only be used in the outer layers of the stone space, so that they do not come into contact with the heating elements.
- Ceramic stones and decorative stones may only be used if they have been approved by the manufacturer and are used according to the their instructions.
- Note that decorative stones are only suitable on the top layer of the stone space. Decorative stones must be placed loosely to ensure sufficient air circulation. Place any decorative stones so that they do not touch the heating elements of an electric sauna heater. If you have a woodburning stove, make sure the stones do not touch the stove’s hot inner frame.
- The warranty does not cover any defects that have been caused by the use of decorative stones or by sauna stones not recommended by the manufacturer.
- The stones should be 5–10 cm in diameter.
- Wash off dust from the stones before piling them into the heater.
Please note when placing the stones:
- The aim is to pile a dense layer of stones against the steel grid and pile the rest of the stones loosely. The dense layer prevents the direct heat radiation from overheating materials around the heater. Be especially careful with the corners where the heating elements are near the grid. The loose piling of stones in the middle lets the air flow through the heater, resulting in good heating of sauna and sauna stones.
- Do not drop stones into the heater.
- Do not wedge stones between the heating elements.
- Pile the stones so that they support each other instead of lying their weight on the heating elements.
- Support the heating elements with stones so that the elements stay vertically straight.
- Do not form a high pile of stones on top of the heater.
- No such objects or devices should be placed inside the heater stone space or near the heater that could change the amount or direction of the air flowing through the heater.
A bare heating element can endanger combustible materials even outside the
safety distances. Check that no heating elements can be seen behind the
stones.
1.1.1. Maintenance
Due to large variation in temperature, the sauna stones disintegrate in use.
Rearrange the stones at least once a year or even more often if the sauna is
in frequent use. At the same time, remove any pieces of stones from the bottom
of the heater and replace any disintegrated stones with new ones. By doing
this, the heating capability of the heater stays optimal and the risk of
overheating is avoided.
Pay attention especially to the gradual settling of the stones. Be sure that
the heating elements do not appear with time. The stones settle most rapidly
within two months of piling.
1.2. Heating of the Sauna
When operating the heater for the first time, both the heater and the stones
emit smell. To remove the smell, the sauna room needs to be efficiently
ventilated. If the heater output is suitable for the sauna room, it will take
about an hour for a properly insulated sauna to reach the required bathing
temperature ( 2.3.). The sauna stones normally reach the bathing temperature
at the same time as the sauna room. A suitable temperature for the sauna room
is about 60–75 °C.
1.3. Using the Heater
When the heater is connected to the power supply and the main switch (see
figure 1) is switched on, the heater is in standby mode and ready for use. I/O
button’s background light glows on the control panel.
WARNING! Before switching the heater on always check that there isn’t anything on top of the heater or inside the given safety distance.
1.3.1. Heater On
Start the heater by pressing the heater I/O button on the control panel.
When the heater starts, the top row of the display will show the set
temperature and the bottom row will show the set on time for five seconds.
When the desired temperature has been reached in the sauna room, the heating
elements are automatically turned off. To maintain the desired temperature,
the heater will automatically turn the heating elements on and off in periods.
If the heater efficiency is suitable and the sauna has been built correctly,
the sauna takes no more than an hour to warm up.
1.3.2. Heater Off
The heater turns off and switches to standby-mode when
• the I/O button is pressed
• the on-time runs out or
• an error occurs.
NOTE! It is essential to check that the heater has turned off after the
on-time has elapsed or the heater has been switched off manually.
1.4. Changing the Settings
The settings menu structure and changing the settings is shown in figures 3a
and 3b.
The programmed temperature value and all values of additional settings are
stored in memory and will also apply when the device is switched on next time.
1.5. Using Accessories
Lighting can be started and shut down separately from other functions. Figure
7.
1.5.1. Lighting
The lighting of the sauna room can be wired so that it can be controlled from
the control panel. (Max 100 W.)
Switch the lights on/off by pressing the control panel button.
1.5.2. Safety and door switch
Safety switch refers to e.g. Harvia SFE, a safety device installed above or
integrated to the heater, preventing the heater from heating should any object
(e.g. towel, piece of clothing) drop or be placed on top of the heater and
cause a fire hazard. Door switch refers to a magnetic switch installed in the
sauna room door frame, opening its circuit when the sauna room door is opened.
The switches are connected to the heater according to their manuals. See also
figure 7 in this manual.
1.5.3. Remote switch
To remotely control the heater’s power input, the heater can be equipped with
an on/off remote switch (e.g. building automation). For more information, see
section 1.7.
1.6. Control panel lock
| Press and hold the heater and light buttons for three seconds.
---|---
| -CL- is shown on the display. Panel lock can be activated only in standby
mode.
Panel lock also prevents remote start.
1.7. Remote control
According to the product standard IEC/EN 60335 -2-53 regulating electrical
sauna heaters, a control panel can be used to remotely control the heater once
the heater or sauna room door is equipped with a secure switch (a safety or a
door switch).
Using with a safety switch : the heater can be turned on remotely, if the
safety switch circuit is closed. If the circuit is open, “SAFE” is displayed
and the heater will not start.
Using with a door switch: remote use mode must be activated by pressing
the heater button for three seconds. If the door switch circuit is open, “door
OPEn” is displayed and the heater returns into standby mode. If the circuit is
closed, the remote use mode is activated and “rc on” is displayed while the
heater button blinks. The heater can now be turned on with a remote switch.
If, during remote use mode, the door is opened, “door OPEn” is displayed and
the heater returns into standby mode.
BASIC SETTINGS
| Basic mode (heater on)
The top row shows the sauna room temperature. The bottom row shows the
remaining on-time. Both indicator lights glow.
---|---
| Press the MENU button to open the settings menu.
| Sauna room temperature
The display shows the sauna room temperature setting. Temperature indicator
light blinks.
• Change the setting to the desired temperature with the – and + buttons. The
range is 40–110 ºC.
| Press the MENU button to access the next setting.
| Remaining on-time
Press the + and – buttons to adjust the remaining on-time.
Example: the heater will be on for 3 hours and 40 minutes.
| Remaining on-time
Press the + and – buttons to adjust the remaining on-time.
Example: the heater will be on for 3 hours and 40 minutes.
| Press the MENU button to exit.
| Basic mode (pre-setting time running, heater off)
The decrease of remaining pre-setting time is shown until zero appears, after
which the heater is switched on.
Figure 3a. Settings menu structure, basic settings
ADDITIONAL SETTINGS
| Heater standby
I/O button’s background light glows on the control panel.
---|---
| The buttons do not glow when the heater is in standby mode.
Open the settings menu by simultaneously pressing the locations of the buttons
–, MENU and + (see figure 2). Press for 5 seconds.
| Setting the remote use
The remote use setting can be changed with the — and + buttons. The options
are “OFF” (remote control disabled), “SAFE” (safety switch) and “door” (door
switch).
See section 2.3.3. for further information.
Confirm the selection with the MENU button.
Setting pause time. Enable or disable the pause time feature with buttons
- and -. Pause time must be enabled, if the heater
is remotely started by an automated schedule (e.g. a weekly timer).
| Press the MENU button to access the next setting.
| Maximum on-time
The maximum on-time can be changed with the – and + buttons. The range is 1–12 hours (6 hours*)).
Example: the heater will be on for 6 hours from the start. (Remaining on-time can be changed, see figure 3a.)
| Press the MENU button to access the next setting.
| Sensor reading adjustment
The reading can be corrected by +/- 10 units. The adjustment does not affect the measured temperature value directly, but changes the measuring curve.
| Press the MENU button to access the next setting.
- Factory setting
| Memory for power failures
The memory for power failures can be turned ON or OFF ).
• When turned on, the system will start again after a break in electricity.
• When turned off, the break will shut the system down. I/O button must be
pressed to restart.
• The safety regulations for memory usage vary from region to region. )
Factory setting
---|---
| Press the MENU button. The heater switches to standby-mode.
Figure 3b. Settings menu structure, additional settings
Pause time: These features are limited by a pause time that prevents the
heater from turning on if it has been less than 6 hours since the heater was
last turned off. Trying to remotely turn the heater on during the pause time
period (6 hours), text ”rESt” is displayed. The heater can be remotely
started after the pause time has elapsed and ”rc” is displayed.
Memory for power failures: the heater resumes operation, if the remote
switch has remained in ON position.
Preset time: if the heater is on preset delay time, it cannot be
controlled with a remote switch. After the preset delay has passed and the
heater is turned on, it can be turned off with a remote switch.
1.8. Power saving mode
If no buttons are pressed in 30 minutes, power saving mode is activated. Only
the heater button (and “rc on”, if remote use mode is active) is lit.
Water properties | Effect Wirkung | Recommendation Empfehlung |
---|---|---|
Humus concentration | Colour, taste, precipitates | <12 mg/l |
Iron concentration Eisengehalt | Colour, odour, taste, precipitates | <0,2 mg/l |
Manganese (Mn) concentration | Colour, odour, taste, precipitates | <0,10 mg/l |
Hardness: most important substances are magnesium (Mg) and lime, i.e. calcium
(Ca)| Precipitates| Mg: <100 mg/l
Ca: <100 mg/l
Chloride-containing water| Corrosion Korrosion| Cl: <100 mg/l
Chlorinated water| Health risk| Forbidden to use
Seawater| Rapid corrosion| Forbidden to use
Arsenic and radon concentration| Health risk| Forbidden to use
Table 1. Water quality requirements
1.9. Throwing Water on Heated Stones
The air in the sauna room becomes dry when warmed up. Therefore, it is
necessary to throw water on the heated stones to reach a suitable level of
humidity in the sauna. The effect of heat and steam on people varies – by
experimenting, you can find the levels of temperature and humidity that suit
you best. You can adjust the nature of the heat from soft to sharp by throwing
water either to the front of the heater or straight on top of the stones.
The maximum volume of the ladle is 0.2 litres.
If an excessive amount of water is poured on the stones, only part of it will
evaporate and the rest may splash as boiling hot water on the bathers. Never
throw water on the stones when there are people near the heater, because hot
steam may burn their skin. The water to be thrown on the heated stones should
meet the requirements of clean household water (table 1). Only special aromas
designed for sauna water may be used. Follow the instructions given on the
package.
1.10. Instructions for Bathing
- Begin by washing yourself.
- Stay in the sauna for as long as you feel comfortable.
- Forget all your troubles and relax.
- According to established sauna conventions, you must not disturb other bathers by speaking in a loud voice.
- Do not force other bathers from the sauna by throwing excessive amounts of water on the stones.
- Cool your skin down as necessary. If you are in good health, you can have a swim if a swimming place or pool is available.
- Wash yourself after bathing.
- Rest for a while and let your pulse go back to normal. Have a drink of fresh water or a soft drink to bring your fluid balance back to normal.
1.11. Warnings
- Staying in the hot sauna for long periods of time makes the body temperature rise, which may be dangerous.
- Keep away from the heater when it is hot. The stones and outer surface of the heater may burn your skin.
- Keep children away from the heater.
- Do not let young, handicapped or ill people bathe in the sauna on their own.
- Consult your doctor about any health-related limitations to bathing.
- Consult your child welfare clinic about taking little babies to the sauna.
- Be very careful when moving in the sauna, as the platform and floors may be slippery.
- Never go to a hot sauna if you have taken alcohol, strong medicines or narcotics.
- Never sleep in a hot sauna.
- Sea air and a humid climate may corrode the metal surfaces of the heater.
- Do not hang clothes to dry in the sauna, as this may cause a risk of fire. Excessive moisture content may also cause damage to the electrical equipment.
| Description| Remedy
---|---|---
E1| Temperature sensor’s measuring circuit broken.| Check the red and yellow
wires to the temperature sensor and their
connections for faults.
E2| Temperature sensor’s measuring circuit short-circuited.| Check the red and
yellow wires to the temperature sensor and their
connections for faults.
E3| Overheat protector’s measuring
circuit broken.| Press the overheat protector’s reset button ( 3.5.).
Check the blue and white wires to the temperature sensor and their
connections for faults.
E9| Connection failure in the system.| Switch the power off from the main
switch. Check the data cable,
sensor cable/s and their connections. Switch the power on.
STATUS MESSAGES
door open | Door switch circuit is open | Close the sauna room door |
---|---|---|
SAFE | Safety switch circuit is open | Remove the object from atop the safety |
switch
rESt| Pause time active| –
rc on| Remote control activated| –
1.11.1. Symbols descriptions
Read operators manual.
Do not cover.
1.12. Troubleshooting
All service operations must be done by professional maintenance personnel.
The heater does not heat.
- Check that the fuses to the heater are in good condition.
- Check that the connection cable is connected (▷ 3.4.).
- Check that the control panel shows a higher figure than the temperature of the sauna.
- Check that the overheat protector has not gone off. (▷ 3.5.)
The sauna room heats slowly. The water thrown on the sauna stones cools down the stones quickly.
- Check that the fuses to the heater are in good condition.
- Check that all heating elements glow when the heater is on.
- Turn the temperature to a higher setting.
- Check that the heater output is sufficient (▷ 2.3.).
- Check the sauna stones (▷ 1.1.). Too tightly piled stones, the settling of stones with time or wrong stone type can hinder the air flow through the heater, which results in reduced heating efficiency.
- Check that the sauna room ventilation has been arranged correctly (▷ 2.2.).
The sauna room heats quickly, but the temperature of the stones remain insufficient. Water thrown on the stones runs through.
- Check that the heater output is not too high (▷ 2.3.).
- Check that the sauna room ventilation has been arranged correctly ( ▷ 2.2.).
Panel or other material near the heater blackens quickly.
- Check that the requirements for safety distances are fulfilled (▷ 3.2.).
- Check the sauna stones ( ▷1.1.). Too tightly piled stones, the settling of stones with time or wrong stone type can hinder the air flow through the heater, which may result in overheating of surrounding materials.
- Check that no heating elements can be seen behind the stones. If heating elements can be seen, rearrange the stones so that the heating elements are covered completely (▷ 1.1.).
- Also see section 2.1.1.
The heater emits smell.
- See section 1.2.
- The hot heater may emphasize odours mixed in the air that are not, however, caused by the sauna or the heater. Examples: paint, glue, oil, seasoning.
SAUNA ROOM
2.1. Sauna Room Structure
A. Insulation wool, thickness 50–100 mm. The sauna room must be insulated
carefully so that the heater output can be kept moderately low.
B. Moisture protection, e.g. aluminium paper. Place the glossy side of the
paper towards the sauna. Tape the seams with aluminium tape.
C. Vent gap of about 10 mm between the moisture protection and panel
(recommendation).
D. Low mass 12–16 mm thick panel board. Before starting the panelling, check
the electric wiring and the reinforcements in the walls required by the heater
and benches.
E. Vent gap of about 3 mm between the wall and ceiling panel.
F. The height of the sauna is usually 2100–2300 mm.
The minimum height depends on the heater (see table 2). The space between the
upper bench and ceiling should not exceed 1200 mm.
G. Use floor coverings made of ceramic materials and dark joint grouts.
Particles disintegrating from the sauna stones and impurities in the sauna
water may stain and/or damage sensitive floor coverings.
NOTE! Check from the fire authorities which parts of the firewall can be
insulated. Flues which are in use must not be insulated.
NOTE! Light protective covers which are installed directly to the wall or
ceiling may be a fire risk.
2.1.1. Blackening of the Sauna Walls
It is perfectly normal for the wooden surfaces of the sauna room to blacken in
time. The blackening may be accelerated by
- sunlight
- heat from the heater
- protective agents on the walls (protective agents have a poor heat resistance level)
- fine particles disintegrating from the sauna stones which rise with the air flow.
2.2. Sauna Room Ventilation
The air in the sauna room should change six times per hour. Figure 5
illustrates different sauna room ventilation options.
A. Supply air vent location. If mechanical exhaust ventilation is used, place
the supply air vent above the heater. If gravity exhaust ventilation is used,
place the supply air vent below or next to the heater. The diameter of the
supply air pipe must be 50–100 mm. Do not place the supply air vent so that
the air flow cools the temperature sensor (▷ 3.3.2.)!
B. Exhaust air vent. Place the exhaust air vent near the floor, as far away
from the heater as possible. The diameter of the exhaust air pipe should be
twice the diameter of the supply air pipe.
C. Optional vent for drying (closed during heating and bathing). The sauna can
also be dried by leaving the door open after bathing.
D. If the exhaust air vent is in the washroom, the gap underneath the sauna
door must be at least 100 mm. Mechanical exhaust ventilation is mandatory.
2.3. Heater Output
When the walls and ceiling are covered with panels and insulation behind the
panels is adequate, the heater output is defined according to the volume of
the sauna. Non-insulated walls (brick, glass block, glass, concrete, tile,
etc.) increase the need for heater output. Add 1,2 m³ to the volume of the
sauna for each non-insulated wall square meter. For example, a 10 m³ sauna
room with a glass door equals the output requirement of about a 12 m³ sauna
room. If the sauna room has log walls, multiply the sauna’s volume by 1,5.
Choose the correct heater output from Table 2.
2.4. Sauna Room Hygiene
Bench towels should be used during bathing to prevent sweat from getting onto
the benches.
The benches, walls and floor of the sauna should be washed thoroughly at least
every six months.
Use a scrubbing brush and sauna detergent.
Wipe dust and dirt from the heater with a damp cloth. Remove lime stains from
the heater using a 10% citric acid solution and rinse.
INSTRUCTIONS FOR INSTALLATION
3.1. Before Installation
Before installing the heater, study the instructions for installation. Check
the following points:
- Is the output and type of the heater suitable for the sauna room? The cubic volumes given in table 2 should be followed.
- Is the supply voltage suitable for the heater?
- The location is suitable for the heater (▷3.2.).
Note! Only one electrical heater may be installed in the sauna room.
Heater | Output | Dimensions | Stones | Sauna room |
---|---|---|---|---|
Width/Depth/Height | Weight | Cubic vol. | Height | |
kW | mm | kg | max. kg | 2.3.! |
min. m³ | max. m³ | |||
PC70XE | 6,8 | 320/320/930 | 10 | 90 |
PC70XW | 6,8 | 320/320/930 | 10 | 90 |
PC90XE | 9,0 | 320/320/930 | 10 | 90 |
PC90XW | 9,0 | 320/320/930 | 10 | 90 |
Table 2. Installation details of the heater
3.2. Place and Safety Distances
The minimum safety distances are described in figure 6.
- It is absolutely necessary to install the heater according to these values. Neglecting them causes a risk of fire.
- Hot pieces of stone can damage floor coverings and cause a risk of fire. The floor coverings of the installation place should be heat-resistant.
- If the heater is to be embedded into bench using the embedding flange, see installation instructions of the flange before making a hole in the bench.
3.3. Electrical Connections
The heater may only be connected to the electrical network in accordance with
the current regulations by an authorised, professional electrician.
-
The heater is semi-stationarily connected to the junction box (figure 7: A) on the sauna wall. The junction box must be splash-proof, and its maximum height from the floor must not exceed 500 mm.
-
Always check condition of the junction box connectors when installing the heater. We recommend screw connectors. Avoid spring-loaded connectors!
-
The connecting cable (figure 7: B) must be of rubber cable type H07RN-F or its equivalent.
NOTE! Due to thermal embrittlement, the use of PVC-insulated wire as the connecting cable of the heater is forbidden. -
If the connecting and installation cables are higher than 1 000 mm from the floor in the sauna or inside the sauna room walls, they must be able to endure a minimum temperature of 170 °C when loaded (for example, SSJ). Electrical equipment installed higher than 1 000 mm from the sauna floor must be approved for use in a temperature of 125 °C (marking T125).
-
In addition to supply connectors, the heaters are equipped with a connector (P), which makes the control of the electric heating possible (figure 7).Voltage control is transmitted from the heater when it is switched on. The control cable for electrical heating is brought directly into the junction box of the heater, and from there to the terminal block of the heater along a rubber cable with the same cross-section area as that of the connecting cable.
3.3.1. Electric Heater Insulation Resistance
When performing the final inspection of the electrical installations, a
“leakage” may be detected when measuring the heater’s insulation resistance.
The reason for this is that the insulating material of the heating elements
has absorbed moisture from the air (storage, transport). After operating the
heater for a few times, the moisture will be removed from the heating
elements.
Do not connect the power feed for the heater through the RCD (residual current
device)!
3.3.2. Installing the Temperature Sensor
Install the sensor as shown in figure 8. If the heater is installed further
than 100 mm from wall, the sensor must be installed on the ceiling.
The supply air vent of the sauna room must not be located near the temperature
sensor.
The air flow near an air vent cools down the sensor, which gives inaccurate
temperature readings to the control unit. As a result, the heater might
overheat. The air vent’s minimum distance from the sensor (figure 5):
• omnidirectional air vent: 1000 mm
• air vent directed away from the sensor: 500 mm
The sensor must be installed to the place defined in these instructions
(figure 8). If the minimum distance is not fulfilled, ventilation must be
changed.
3.3.3. Installation of the Control Panel
The control panel is splashproof and has a small operating voltage. The panel
can be installed in the washing or dressing room, or in the living quarters.
If the panel is installed in the sauna room, it must be at the minimum safety
distance from the heater and at a maximum height of one metre from the floor.
Figure 9.
Conductor tubing (ø 30 mm) inside the wall structure allows you to thread the
data cable hidden within the wall – otherwise the installation will have to be
on the wall surface. We recommend you to install the control panel embedded in
to the wall and far away from possible splashes.
3.4. Installing the Heater
See figure 10.
- Connect cables to the heater (▷ 3.3.).
- Place the heater and adjust the heater vertically straight using the adjustable legs.
- Use fixing kits (2 pcs) to fix the heater to sauna’s structures.
3.5. Resetting the Overheat Protector
The sensor box contains a temperature sensor and an overheat protector. If the
temperature in the sensor’s environment rises too high, the overheat protector
cuts off the heater power. Resetting the overheat protector is shown in figure
11.
The reason for the going off must be determined before the button is
pressed.
SPARE PARTS
We recommend to use only the manufacturer’s spare parts.
GLOBAL: P.O.Box 12 | Teollisuustie 1-7 | 40951 Muurame | FINLAND |
+358 207 464 000 | harvia@harvia.fi |
www.harvia.com
CENTRAL EUROPE: Sentiotec GmbH | Division of Harvia Group |
Wartenburger Straße 31, A-4840 Vöcklabruck
T +43 (0) 7672/22 900-50 | F -80 |
info@sentiotec.com |
www.sentiotec.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>