Product Description

The DMDinline S is an actuator designed for intelligent system protection and software-dependent functions. It comes with various interfaces for motor and flange side connections, ensuring versatile usage in different applications.

Intended Use
The DMDinline S actuator is intended for use by assembly personnel to ensure safe operation and functionality within a specified system. It should be assembled according to the provided instructions to prevent hazards and damage.

Delivery Scope
The delivery scope includes the DMDinline S actuator, necessary cables for connections, and any additional accessories required for assembly.

Unpacking
When unpacking the product, ensure all components are present and undamaged. Check for any signs of external damage before proceeding with assembly.

Assembly

General Assembly
Follow the provided instructions for assembling the DMDinline S actuator. Pay attention to actuator dimensions, installation options, tolerances, and default settings.

Motor Side Interface
Connect the actuator to the motor side interface following the specified guidelines to ensure proper functionality.

Flange Side Interface
Securely attach the actuator to the flange side interface as outlined in the manual to maintain stability during operation.

Cable Connection
Properly connect the cables according to the instructions provided to establish necessary electrical connections.

Software-Dependent Functions
Activate and configure any software-dependent functions as required for your specific application. Refer to the software manual for detailed instructions.

Intelligent System Protection (ISP)
The ISP feature ensures system protection against potential damages or malfunctions. Configure the ISP settings according to your system requirements for optimal performance.

Maintenance
Regular maintenance of the DMDinline S actuator is essential to ensure long- term functionality. Follow the maintenance schedule provided in the manual to prevent issues.

Troubleshooting
Refer to the troubleshooting section in the manual in case of any operational issues or malfunctions. Follow the recommended steps to identify and resolve problems effectively.

FAQ

Q: What should I do if the actuator fails to operate?
A: Check the power supply, connections, and settings to ensure proper functionality. If issues persist, refer to the troubleshooting section for further assistance.

DMDinline S Operating Manual
Document Version 1.0 / Oktober 2023
This document was originally published in English.
LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria

Phone: +43 (0) 3462 51 98 0
Fax: +43 (0) 3462 51 98 1030
Internet: www.logicdata.net
Email: office.at@logicdata.net

INTRODUCTION

The product documentation consists of this manual and a datasheet.
This document is intended to enable the assembly personnel to work safely with the DMDinline S actuator. The assembly personnel must therefore always have the complete documentation available. The document must be complete and in a perfectly legible condition. Follow the instructions in this document to avoid hazards and to prevent damage to the DMDinline S.
The information in this document has been compiled with great care. We strive to ensure the accuracy and completeness of the content by revising it and updating it regularly, however, no guarantee can be given for its accuracy and completeness.

COPYRIGHT
© September 2023 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for those listed in Chapter 1.2 Royalty-free use of images and text on page 5.

ROYALTY-FREE USE OF IMAGES AND TEXT
After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used free of charge by the customer. They should be used to prepare end user documentation for Height-Adjustable Table Systems. The license does not include logos, designs, and page layout elements belonging to LOGICDATA. The transfer of this license to third parties without permission from LOGICDATA is exclu-ded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind.

TRADEMARKS
Documentation may include the representation of registered trademarks of goods or services, as well as information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

SYMBOLS AND SIGNAL WORDS USED
Safety Notices contain both symbols and signal words. The signal word indicates the severity of the hazard.

WARNING| Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
---|---
CAUTION| Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE| The label NOTICE indicates a situation that will not lead to personal injury, but could lead to damage to the product or the environment.
NOTICE| Damage due to electrostatic discharge (ESD)
---|---

SAFETY

GENERAL SAFETY REGULATIONS AND OBLIGATIONS
In general, the following safety regulations and obligations apply when handling the product:

  • The DMDinline S actuator may only be operated in a clean and perfect condition.
  • Do not remove, change, bridge or bypass any protection, safety or monitoring equipment.
  • Do not convert or modify the DMDinline S actuator without written approval from LOGICDATA.
  • In the event of malfunction or damage, the DMDinline S actuator must be replaced immediately.
  • Do not attempt to repair the acuator yourself.
  • Hardware replacement is only allowed in a de-energized state.
  • For the operation of the system, the national worker protection conditions and the national safety and accident prevention regulations apply.

WARNING Hazard from electric shock

The LOGICleg is designed as IEC Class III equipment. Unauthorised use of voltages higher than those specified than will result in death or serious injury from electric shock, fire or other malfunctions. See Nameplate or Datasheet for detailed information.

  • Use only within the rated voltage range
  • Use only with the manufacturer‘s original parts

UALIFIED PERSONS
The DMDinline S may only be installed and commissioned by qualified persons who are authorized for instal-lation planning, installation, commissioning or maintenance/servicing and who have read and understood the DMDinline S documentation. Qualified persons have the necessary expertise to test, assess and manage electrical and mechatronic products and systems in accordance with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing through their education, work experience and recent professional activity. They know and adhere to the basic regulations on occupational safety and accident prevention and the basic norms and specialist standards applicable to the specific application.

LIABILITY
The products comply with the applicable state of the art health and safety regulations. Nevertheless, dan-gers can result from incorrect operation or misuse.

LOGICDATA is not liable for damages caused by:

  • Improper use of the products
  • Disregard of the documentation
  • Unauthorized changes to the products
  • Improper work on and with the DMDinline S
  • Operating a damaged product
  • Wear parts
  • Improperly performed repairs
  • Unauthorized, improper change of operating parameters
  • Disasters, external influence and force majeure

Responsible for the LOGICDATA products in the specific application and compliance with the relevant di-rectives, standards and laws is the manufacturer of the height-adjustable tables in which the LOGICDATA products are installed. LOGICDATA shall not be held liable for any damage that is directly or indirectly at-tributable to the delivery, performance or use of this document. Each reseller must take into account the relevant safety standards and guidelines for his product in which the DMDinline S is installed.

PRODUCT

DESCRIPTION
The DMDinline S is an actuator for electrically height-adjustable tables. It is installed by the customer in a column for electrically height-adjustable tables. It is controlled by a control unit from LOGICDATA, to which different hand switches can be connected. Several drives can be operated synchronously on one control unit.

LOGICDATA-DMDinline-S-Height-Adjustable-Desks-Components-FIG-
\(3\)

1 Attachment point on motor end (screws and rubber discs provided)
2 Motor
3 Flange attachment point

INTENDED USE
The DMDinline S actuator may only be installed in telescopic tubes to adjust electrically height-adjustable tables and used for this purpose exclusively. The intended use is to adjust the table height electrically. Only power supply units from LOGICDATA, which are parameterized for the DMDinline S, may be used for this purpose. The actuators must be assembled, commissioned and functionally checked by qualified personnel. Any other use that does not conform to the intended use will result in the loss of warranty and warranty claims.

The basic function is the upward and downward movement (of a table top). This function can be executed with suitable hand switches from LOGICDATA.

NOTICE
Permissible drive loads and speeds always refer to the product DMDinline S and not to the additional load on the table system. The reseller must take additional loads such as e.g. friction forces, the deadweight of the table components and torque loads into consideration. The newly determined permissible load must be specified in the parent documentation of the final product.

DELIVERY SCOPE

The standard scope of delivery for the DMDinline S actuator consists of the following components:

LOGICDATA-DMDinline-S-Height-Adjustable-Desks-Components-FIG-
\(4\)

Standard delivery scope

1 DMDinline S actuator
2 Two mounting screws incl. rubber disks (LOG-PRT-SD-MOUNTINGSCREW)

UNPACKING

The DMDinline S actuator is packaged in a carton.

NOTICE
Ensure proper ESD handling during unpacking. Errors that can be attributed to electrostatic discharge will void warranty claims

To unpack, proceed as follows:

  1. Remove the packaging material from the drive components.
  2. Check the contents of the package for completeness and damage.
  3. Provide the operating manual to the operating personnel.
  4. Dispose of the packaging material.

NOTICE
Dispose of the packaging material in an environmentally friendly manner (separate the plastic parts and the cardboard by type).

ASSEMBLY

GENERAL ASSEMBLY

NOTICE

  • Before assembly and operation, the DMDinline S must be acclimatised to the ambient conditions.
  • Ensure proper ESD handling throughout the installation. Failures that can be attributed to electrostatic discharge will void warranty claims.
  • Safety shoes and gloves must be worn during the assembly of the actuator.

ACTUATOR DIMENSIONS
Figure 3 shows the dimensions of the DMDinline S actuator in the retracted and extended state.

LOGICDATA-DMDinline-S-Height-Adjustable-Desks-Components-FIG-
\(5\)

INSTALLATION OPTIONS
Depending on the type of height-adjustable column design, different installation options are possible. In this document, the installation variants are characterized as follows, depending on the types of height-ad-justable columns:

  • “Thick end up”: In this variant, the tube with the largest diameter is at the top (table top).
  • “Thick end down”: In this variant, the tube with the largest diameter is at the bottom (floor).

The DMDinline S actuator can be used for both variants.

LOGICDATA-DMDinline-S-Height-Adjustable-Desks-Components-FIG-
\(6\)

NOTICE

  • Regardless of the installation variant, the inner diameter of the inner tube must be selected so that a surrounding air gap of min 3 mm between the inner wall of the tube and the DMDinline S is guaranteed.
  • As shown in Figure 5, height-adjustable columns must be designed so that the motor end of the DMDinline S is always up
INSTALLATION TOLERANCES

NOTICE
In order to ensure proper functioning, height-adjustable columns must comply with the tolerances specified by LOGICDATA. Otherwise, the warranty claims are void. These tolerances are published by LOGICDATA on request.

DEFAULT SETTINGS

  • Failure to follow the instructions below may result in damage!
  • LOGICDATA recommends measuring the dimensions of the DMDinline S before assembly with a gauge or other suitable measuring equipment.
  • In order to utilize the complete stroke of the drive, a corresponding design of the height-adjustable column is necessary. It is important that the drive reaches the final position before the tube.
  • Deviating flange settings may only be implemented in consultation with LOGICDATA.

Recommended assembly procedure:

NOTICE

  • The assembly procedure shown is based on a height-adjustable column design in which the top plate can be removed (i.e., it is not permanently connected to the thick end). For instructions on mounting with other height-adjustable column constructions, please contact LOGICDATA.
  • LOGICDATA recommends measuring the gliding properties of the height-adjustable column without the installed drive after this step.
  • For suitable production aids, joining forces and joining speeds or detailed information on the assembly process, please contact LOGICDATA. Failure to perform the joining process properly may result in damage to the DMDinline S.
MOTOR SIDE INTERFACE

NOTICE

  • The design specifications for the top plate are available from LOGICDATA only on request. These includes dimensions and tolerances as well as notes on material selection and assembly.
  • The screws and rubber disks are supplied together with the drive. The mounting screws must be tightened to the recommended tightening torque of 2.5 – 3 Nm.
  • The DMDinline S can only be mounted once with the supplied screws, otherwise correct tightening of the mounting screws can not be guaranteed.
  • Mounting without rubber disks is not permitted.

CAUTION

  • Danger due to insecure connection
    To ensure a secure connection, the top plate must be designed exactly to the specifications of LOGICDATA. Otherwise, the warranty claims are void.

FLANGE SIDE INTERFACE
The figure below provides an overview of the components required to assemble the drive on the flange end.

1 Mounting screw (adapted by the customer to bottom plate)
2 Bottom plate (developed by the customer, design specifications of

LOGICDATA)
3| Flange adjustment point

NOTICE
The design specifications for the bottom plate are available from LOGICDATA only on request. These includes dimensions and tolerances as well as notes on material selection and assembly.

CAUTION
Danger due to insecure connection
To ensure a secure connection, the top plate must be designed exactly to the specifications of LOGICDATA. Otherwise, the warranty claims are void.

CABLE CONNECTION
After the DMDinline D is installed in the height-adjustable column, connect the motor cable to the actuator. Be careful not to damage the cable when installing the finished column.

SOFTWARE-DEPENDENT FUNCTIONS

The description of the software-dependent functions can be found in the Dynamic Motion System manual.

INTELLIGENT SYSTEM PROTECTION (ISP)

ISP (Intelligent System Protection) reduces the risk of pinching when a moving table hits an obstacle. It is important that all actuators of a table are either with or without ISP sensors. For more information concer-ning ISP, refer to the Dynamic Motion System Manual.

DISASSEMBLY
For disassembly, disconnect the DMDinline S from the power supply and proceed in reverse order to assembly.

MAINTENANCE

WARNING

  • Hazards from the use of incorrect accessory parts
    Only use original accessory parts. These may only be installed by expert service personnel. Otherwise your warranty claims will be void.

  • Hazard from inappropriate repairs
    Contact your customer service immediately in the event of a malfunction. Only original spare parts are approved for the repair of the drives. These may only be replaced by expert service personnel. Otherwise your warranty claims will be void.

TROUBLESHOOTING

Please refer to the Dynamic Motion Manual for troubleshooting DMDinline actuators. For technical problems, please contract our support at:

Phone: +43 (0) 3462 51 98 0
Fax: +43 (0) 3462 51 98 1030
Email: office.at@logicdata.net

Always provide the product name and the revision status according to the type plate with any support request.
In case of a defect, replace the DMDinline S as a whole.

ADDITIONAL INFORMATION

TECHNICAL SPECIFICATIONS
You can find the technical data of your actuator in the corresponding data sheet.

OPTIONAL PRODUCTS
NOTICE You can find information about available optional products in the current product catalog and at www.logicdata.net

DISPOSAL
Dispose of all components separately from household waste. Use designated collection points or disposal companies authorized for this purpose.

LOGICDATA
Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria

Phone: +43 (0)3462 5198 0
Fax: +43 (0)3462 5198 1030
E-mail: office.at@logicdata.net
Internet: http://www.logicdata.net

LOGICDATA North America, Inc.
13617 Woodlawn Hills Dr.
Cedar Springs, MI 49319
USA
Phone: +1 (616) 328 8841
E-mail: office.na@logicdata.net

www.logicdata.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals