LOGICDATA DMIclassic C Dynamic Motion System User Manual

June 4, 2024
LOGICDATA

LOGICDATA DMIclassic C Dynamic Motion System

LOGICDATA-DMIclassic-C-Dynamic-Motion-System-
PRODUCT

GENERAL INFORMATION

Documentation for the DMUI-HSU consists of this Operating Manual and several other documents (Other applicable documents, page 5). Assembly personnel must read all documentation before starting assembly. Keep all documentation for as long as the product is in your possession. Ensure that all documentation is provided to subsequent owners. Go to www.logicdata.net for more information and support. This Manual may change without notice. The most recent version is available on our website.

OTHER APPLICABLE DOCUMENTS

This Operating Manual is part of the documentation required to safely assemble and operate the DYNAMIC MOTION SYSTEM (DM System). Other applicable documents include:

  • DYNAMIC MOTION System Manual
  • Datasheet and Operating Manual for the installed DYNAMIC MOTION Actuator
  • Datasheet for the installed Power Unit

COPYRIGHT

© February 2022 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for those listed in Chapter 1.3 Royalty-free use of images and text on page 5.

ROYALTY-FREE USE OF IMAGES AND TEXT

After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used free of charge by the customer for 10 years after delivery. They should be used to prepare end-user documentation for Height- Adjustable Table Systems. The license does not include logos, designs, and page layout elements belonging to LOGIC DATA. The Reseller may make any necessary changes to the text and images to adapt them for the purpose of end- user documentation. Texts and images may not be sold in their current state and may not be published or sublicensed digitally. The transfer of this license to third parties without permission from LOGIC DATA is excluded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind. Contact LOGIC DATA to obtain text or images in an editable format (documentation@logicdata.net).

TRADEMARKS

Documentation may include the representation of registered trademarks of goods or services, as well as information about copyright or other proprietary expertise of LOGIC DATA or third parties. In all cases, all rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of LOGIC DATA Electronic & Software GmbH in the USA, the European Union, and other countries.

SAFETY

TARGET AUDIENCE

This Operating Manual is intended for Skilled Persons only. Refer to Chapter 2.8 Skilled Persons on page 9 to ensure that personnel meets all requirements.

GENERAL SAFETY REGULATIONS

In general, the following safety regulations and obligations apply when handling the product:

  • Do not operate the product unless it is in a clean and perfect condition
  • Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment
  • Do not convert or modify any components without written approval from LOGICDATA
  • In the event of malfunction or damage, faulty components must be replaced immediately
  • Unauthorized repairs are prohibited
  • Do not attempt to replace hardware unless the product is in a de-energized state
  • Only Skilled Persons are allowed to work with DMUI-HSU Handsets
  • Ensure that national worker protection conditions and national safety and accident prevention regulations are observed during the operation of the system

INTENDED USE

The DMUI-HSU is a Handset for electrically Height-Adjustable Tables. It is installed by Resellers into Height- Adjustable Table systems. It controls Height-Adjustable Table systems via an integrated Control Unit in the connected DYNAMIC MOTION Actuator. It is intended for indoor use only. It may only be installed in compatible Height-Adjustable Tables and with LOGIC DATA- approved accessories. Contact LOGIC DATA for further details. Use beyond or outside the intended use will void the product’s warranty.

REASONABLY FORESEEABLE MISUSE

Usage outside of the intended use for each product may lead to a minor injury, serious injury, or even death. Reasonably foreseeable misuse of DMUI-HSU Handsets includes, but does not extend to:

  • Connecting unauthorized parts to the product. If you are unsure as to whether a part can be used with a DMUI-HSU Handset, contact LOGIC DATA for further information.

EXPLANATION OF SYMBOLS AND SIGNAL WORDS

Safety Notices contain both symbols and signal words. The signal word indicates the severity of the hazard.

  • DANGER: Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
  • WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
  • CAUTION: Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
  • NOTICE: Indicates a situation that, if not avoided, could result in damage to the product through electrostatic discharge (ESD).
    • Indicates a situation that will not lead to personal injury, but could lead to damage to the device or the environment.
  • INFO: Indicates the protection class of the device: Protection Class III. Protection Class III devices may only be connected to SELV or PELV power sources.
    • Indicates important tips for handling the product.

LIABILITY

LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by:

  • Improper product use
  • Disregard of the documentation
  • Unauthorized product alterations
  • Improper work on and with the product
  • Operation of damaged products
  • Wear parts
  • Improperly performed repairs
  • Unauthorized changes to the operating parameters
  • Disasters, external influence, and force majeure

The information in this Operating Manual describes the characteristics of the product without assurances. Resellers assume responsibility for the LOGIC DATA products installed in their applications. They must ensure their product complies with all relevant directives, standards, and laws. LOGICDATA shall not be held liable for any damage that is directly or indirectly caused by the delivery or use of this document. Resellers must observe the relevant safety standards and guidelines for each product in the Table System.

RESIDUAL RISKS

Residual risks are the risks that remain after all relevant safety standards have been complied with. These have been evaluated in the form of a risk assessment. Residual risks associated with assembly and installation of DMUI- HSU Handsets are listed here and throughout this Operating Manual. The risks associated with the system as a whole are listed in the System Manual. See also Chapter 1.1 Other Applicable Documents on page 5. The symbols and signal words used in this Operating Manual are listed in Chapter 2.5 Explanation of Symbols and Signal Words on page 7.

WARNING: Risk of death or serious injury through electric shocks

The DMUI-HSU is an electrical device. Although you will not have to connect any products to the Power Unit during assembly, basic safety precautions must be taken at all times. Failure to observe electrical safety precautions may lead to death or serious injury through electric shocks.

  • Never open a DMUI-HSU Handset
  • Ensure that the product is not connected to the Power Unit during assembly
  • Do not convert or modify the DMUI-HSU Handset in any way
  • Do not immerse the DMUI-HSU Handset or its components in liquid. Clean only with a dry or slightly damp cloth
  • Do not place the Cable of the DMUI-HSU Handset on heated surfaces
  • Check the housing and cables of the DMUI-HSU Handset for visible damage. Do not install or operate damaged products

Risk of death or serious injury in explosive atmospheres

Operating the Handset in potentially explosive atmospheres may lead to death or serious injury through explosions.

  • Read the relevant directives to determine if an atmosphere is potentially explosive
  • Do not operate the Handset in potentially explosive atmospheres

CAUTION: Risk of minor or moderate injury through tripping

During the assembly process, you may have to step over Cables. Tripping over Cables may lead to minor or moderate injury.

  • Ensure that the assembly area is kept clear of unnecessary obstructions
  • Be careful not to trip over Cables

Risk of minor or moderate injury through crushing

If any Handset Key becomes stuck while the system is in motion, the system may not stop properly. This may lead to minor or moderate injury through crushing.

  • Disconnect the system immediately if any Handset Key becomes stuck
SKILLED PERSONS

CAUTION: Risk of injury through incorrect assembly Only Skilled Persons have the expertise to complete the assembly process safely. Assembly by Unskilled Persons may lead to minor or moderate injury.

  • Ensure that only Skilled Persons are allowed to complete assembly
  • Ensure that persons with limited ability to react to danger do not take part in the assembly process

DMUI-HSU Handsets may only be installed by Skilled Persons. A Skilled Person is defined as someone who

  • Is authorized for installation planning, installation, commissioning, or servicing of the product
  • Has read and understood all documentation relevant to the DYNAMIC MOTION system
  • Has the technical education, training, and/or experience to perceive risks and avoid hazards
  • Has knowledge of the specialist standards applicable to the product
  • Has the expertise to test, assess, and manage electrical and mechatronic products and systems in accordance with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing
NOTES FOR RESELLERS

Resellers are companies that purchase LOGIC DATA products for installation in their own products.

INFO

  • For reasons of EU conformity and product safety, Resellers should provide end users with an Operating Manual in their native EU official language.
  • Operating Manuals must include all the safety instructions that end users require to handle the product safely. They must also include an instruction to always keep the Operating Manual in the immediate vicinity of the product.
  • No unauthorized persons (young children, persons under the influence of medications, etc.) should be allowed to handle the product.
  • Resellers must perform a risk assessment on their product that covers residual hazards.
  • It must include measures to mitigate risk, or reference the product’s, Operating Manual.

The Charter of the French Language (La Charte de la langue française) or Bill 101 (Loi 101) guarantees the right of the population of Quebec to conduct business and commercial activities in French. The bill applies to all products sold and used in Quebec. For table systems that will be sold or used in Quebec, Resellers must provide all productrelevant texts in French. These include, but are not limited to:

  • Operating Manuals
  • All other product documentation, including datasheets
  • Inscriptions on the product (such as labels), including those on product packaging
  • Warranty certificates

The French inscription may be accompanied with a translation or translations, but no inscription in another language may be given greater prominence than that in French.

SCOPE OF DELIVERY

The standard scope of delivery for the DMUI-HSU consists of the Handset, its pre-attached cable, and 3 Mounting Screws. All other components necessary for installing the Handset must be supplied separately by the reseller.

UNPACKAGING

NOTICE: Ensure proper ESD handling during un-packaging. Damage that can be attributed to electrostatic discharge will void warranty claims.

To unpackage the product

  1. Remove all components from the packaging
  2. Check the contents of the package for completeness and damage
  3. Provide the Operating Manual to the operating personnel
  4. Dispose of the packaging material

NOTICE: Dispose of the packaging material in an environmentally friendly manner. Remember to separate plastic parts from the cardboard packaging.

PRODUCT

Fig.1 shows a standard model of the DMUI-HSU Handset. The exact variant is denoted by the product’s order code. Consult the accompanying datasheet to ensure that you have received the correct variant.

KEY PRODUCT FEATURES

LOGICDATA-DMIclassic-C-Dynamic-Motion-System-fig-1

1 Memory Position Keys
2 Mounting Points
3 UP / DOWN Keys
4 SAVE Key
5 Display
6 Mounting Plate (for sliding mechanism)

ABOUT THE SLIDING MECHANISM

The Sliding Mechanism is a feature of the DMUI-HSU Handset that allows the handset to be stowed under the table, during transportation or when it is not being used. To move the retracted position: Push the handset inwards toward the tabletop until it clicks into place. To move the extended position: Push the handset to release it, then move gently outwards.

DIMENSIONS

LOGICDATA-DMIclassic-C-Dynamic-Motion-System-fig-2

Length| 69.5 mm | 2.736 “
---|---
Width| 137.2 mm | 5.404 “
Height (to the underside of Table Top)| 24.7 mm | 0.974 “

DRILLING TEMPLATE

When placing the drilling holes, it must be ensured that the Handset does not protrude from the front edge of the Table Top while in the retracted position. To ensure the correct position:

LOGICDATA-DMIclassic-C-Dynamic-Motion-System-fig-3

  • The two drilling holes at the front of the plate must be 31.5 mm from the front edge of the table.
  • The two drilling holes must be placed in a line parallel to the front edge of the table and 46 mm apart.
  • The single drilling hole at the back of the plate must be 45.5 mm from the front edge of the table.
  • The center of the single drilling hole must be 23 mm from the width of each of the two front holes.

The Side Edge of the DMUI-HSU does not have to be flush with the Table’s Side Edge. To avoid protrusion over the side edge, leave a gap of at least 70 mm from the central hole to the side edge of the table.

ASSEMBLY

This chapter describes the process of installing the DMUI-HSU Handset into the DYNAMIC MOTION System.

SAFETY DURING ASSEMBLY

WARNING: Risk of death or serious injury through electric shocks

DMUI-HSU Handsets are electrical devices. Basic safety precautions must be taken at all times. Failure to observe electrical safety precautions may lead to death or serious injury through electric shocks.

  • Never open the Handset
  • Ensure that the Handset is not connected to the Power Unit during assembly
  • Do not convert or modify the Handset in any way
  • Check the housing and cables of the Handset for visible damage. Do not install or operate damaged products.

CAUTION: Risk of minor or moderate injury through improper handling

Improper handling of the product during assembly may lead to minor or moderate injury through cutting, pinching, and crushing.

  • Avoid contact with sharp edges
  • Be careful while handling tools that may cause personal injury
  • Ensure assembly complies with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing
  • Read all instructions and safety advice carefully

Risk of minor or moderate injury through tripping

During assembly and operation, poorly routed Cables may become a trip hazard. Tripping over Cables may lead to minor or moderate injury.

  • Ensure that Cables are routed properly to avoid trip hazards
  • Be careful not to trip over Cables when installing the Handset

NOTICE

  • Ensure proper ESD handling during assembly. Damage that can be attributed to electrostatic discharge will void warranty claims.
  • To avoid damage to the product, measure the dimensions of the Handset before assembly.
  • Before assembly, all parts must be acclimatized to the ambient conditions.
  • Do not lift the Handset by its cable. This will cause irreparable damage to the product.

INFO: Perform a product risk assessment so that you can respond to potential residual hazards. Assembly instructions must be included in your end-user Operating Manual.

REQUIRED COMPONENTS
1 x DMUI-HSU Hansdet
3 x Mounting Screws
Tool Drill or Drilling Machine
Tool Screwdriver

INFO: Screw specifications

The Mounting Screws are provided by LOGIC DATA with the Handset. These are 16 mm in length, with a 3 mm thread and 8 mm head diameter.

PROCESS
  1. Place the Handset into the rails of the sliding plate.
  2. Position the Handset in the desired position under the table top and mark the position of the Mounting Points. Ensure the Handset is in the retracted position and does not protrude from the edge of the Table Top.
  3. Drill the holes for the Mounting Screws into the Table Top at the marked points.
  4. Use the screwdriver and 3 Mounting Screws to attach the Handset to the Table Top at the drilled holes.

NOTICE: The required tightening torque depends on the material of the Table Top. Do not exceed 2 Nm.

COMPLETING ASSEMBLY

After the DMUI-HSU is attached to the Table Top, you must connect the Cable to the Power Hub. Refer to the manual for your chosen Power Hub for instructions.

SYSTEM INFORMATION

When a DMUI-HSU-Handset is installed alongside the DYNAMIC MOTION system, error messages are displayed on the digital display panel. These are as follows:

Signal

|

Message

|

Required Actions

---|---|---

The display shows “Hot”.

| Overheating protection has been activated.| Wait for the overheated components to cool.

The display shows “ISP”.

| The system has recognized a collision.| Release all Keys and wait for the Drive Back function to be completed.

The display shows “Con”, then “Err”.

| The system has recognized a connection error.| Release all Keys and wait for 5 seconds. Then, try again.

Disconnect the Power Unit from the Mains. Then, disconnect System from the Power Unit. Reconnect the system again, then operate the DM System as normal.

The display shows “Err”, then an error number.

| An internal error has occurred.| Read the table below to find the correct response to the error code shown.

Code

|

Message

|

Required Actions

---|---|---
1| Firmware Error| Disconnect the Power Unit from the Mains. Then, dis- connect System from the Power Unit. Reconnect the system again, then operate the DM System as normal.
2| Motor Over Current| Release all Keys and wait for 5 seconds. Then, try again.
3| DC Over Voltage| Release all Keys and wait for 5 seconds. Then, try again.
8| Impulse Detection Timeout| Perform a Position Reset Procedure (see System Manual)
11| Speed cannot be achieved| Release all Keys and wait for 5 seconds. Then, try again.
12| Power Stage Overcurrent| Release all Keys and wait for 5 seconds. Then, try again.
---|---|---
13| DC Under Voltage| Release all Keys and wait for 5 seconds. Then, try again.
14| Critical DC Over Voltage| Release all Keys and wait for 5 seconds. Then, try again.
15| Strain Gauge is defective| Release all Keys and wait for 5 seconds. Then, try again.

Contact LOGICDATA if the problem persists. Do not operate the DM System if components are broken.

17| Error during pairing sequence| Disconnect the Power Unit from the Mains. Then, dis- connect System from the Power Unit. Reconnect the system again, then operate the DM System as normal.

If this fails, perform a factory reset (see DM System Manual).

18| Parameterization or firmware of different Actuators in the Table System are incompatible.| Re-paramaterize the Actuators. Contact LOGICDATA for further information.
19| Too many / too few Actuators connected| Connect the correct number of Actuators (as specified in setup).
20| Motor short circuit and/or open load| Contact LOGICDATA.
21| Firmware Error| Disconnect the Power Unit from the Mains. Then, dis- connect System from the Power Unit. Reconnect the system again, then operate the DM System as normal.
22| Power Unit overload| Release all Keys and wait for 5 seconds. Then, try again.
23| Motor Under Voltage| Release all Keys and wait for 5 seconds. Then, try again.

NOTICE: Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA for further information.

OPERATION

Instructions for operating the system can be found in the DYNAMIC MOTION System Manual. A list of core features can be found below. Handset Keys are represented as follows for further description:

|

UP Key

---|---
| DOWN Key
| SAVE Key
  1| Memory Position Key 1
  2| Memory Position Key 2
  3| Memory Position Key 3
  4| Memory Position Key 4

ADJUSTING THE TABLE TOP HEIGHT

CAUTION: Risk of minor or moderate injury through crushing

Your fingers may be crushed when you attempt to change the height of the table

  • Keep fingers away from moving parts
  • Ensure that no persons or objects are in the table’s range of motion

INFO: The Table Top will move up or down until the UP or DOWN Key is released, or if a pre-defined stopping point has been reached.

To move the Table Top UP
  • Press and hold the UP Key until the desired height has been reached

To move the Table Top DOWN

  • Press and hold the DOWN Key until the desired height has been reached

SAVING A MEMORY POSITION

This function saves a set Table Top position. One Memory Position can be saved per Memory Position Key.

| 1. Move the table to the desired height ( Chapter 5.1.1, Adjusting the Table Top height )
---|---
7   3| ▸  The display shows the Table Top height (e.g. 73 cm)
| 2. Press the SAVE Key.
  2|

3. Press the Memory Position Key (e.g. 2)

S   2| ▸  The display shows S 2
7   3| ▸  After about two seconds, the Table Top height is displayed again

ADJUSTING THE TABLE TO A MEMORY POSITION

Version A (without double-click function)

2 1.  Press and hold the required Memory Position Key (e.g. 2).
  ▸ The Table Top will move until the saved Table Top height has been

reached. If you release the Key before the Memory Position is reached, the table will stop.
  2| ****

2. Release the Memory Position Key

7   3| ****

▸  The display shows the Table Top height (e.g. 73 cm)

Version B (Auto-Movement with double-click function):

INFO

  • The double-click function is available only for DM Systems sold in US markets.
  • If you press any Key while the table moves to a Memory Position, the Table Top will stop moving immediately. To continue, you must select the Memory Position again.

CAUTION: Risk of minor or moderate injury through unauthorized modifications

The firmware is delivered with a deactivated double-click function. If you activate this function, the grading of the safety functions according to EN ISO 13849-1 PL b, Category B, are no longer valid, as the legal requirements in the standard are no longer met.

  • If you activate the function, perform a new risk new assessment to meet the higher safety requirements (EN 60335-1). These cannot be met by the DM System
  • LOGICDATA is not liable for injuries or damage caused by activating the double-click function

  2| ****

Double-click the required Memory Position Key (e.g. 2)

---|---
 | ▸  The table will move to the Memory Position. You do not have to hold the Key
7   3| ****

▸  The display shows the Table Top height (e.g. 73 cm)

CHANGING THE HEIGHT DISPLAY (CM/INCH)

DMUI-HSU Handsets can display the height of the Table Top in both centimeters and inches. To change the displayed unit of measurement:

|

1. Press and hold Memory Position Keys 1 and 2, alongside the UP Key

---|---
 | |

|

The display shows S and a number , e.g.

|

S 7.

| |  | 2. Press the UP Key or DOWN Key until the display shows S 5.
|

|

The display shows S 5.

| 3. Press the SAVE Key

▸ If the display was previously set to cm, it is now set to inches.

▸ If the display was previously set to inches, it is now set to cm.

ADDITIONAL INFORMATION

DISASSEMBLY

  • To disassemble the DMUI-HSU Handset, ensure that it has been disconnected from the Power Unit. Then, follow the assembly instructions for your chosen product in reverse order.

MAINTENANCE

  • The DMUI-HSU is maintenance-free for its entire service life time.

WARNING: Risk of death or serious injury through electric shocks and other hazards

Using a DMUI-HSU Handset alongside unauthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards.

  • Only use accessory parts produced or approved by LOGICDATA
  • Only use replacement parts produced or approved by LOGICDATA
  • Only allow Skilled Persons to perform repairs or install accessory parts
  • Contact customer services immediately if the system malfunctions

The use of unauthorized spare or accessory parts may cause system damage. Warranty claims are void in this scenario.

CLEANING

  1. Disconnect the system from the Power Unit
  2. Wait 30 seconds for residual voltage to dissipate.
  3. Wipe the surface of the Handset with a dry or slightly damp soft cloth. Never immerse the Handset into liquid
  4. Wait for the Handset to dry completely
  5. Reconnect the Power Unit

TROUBLESHOOTING

A list of common problems and their solutions can be found in the DYNAMIC MOTION System Manual. Most errors with DMUI-HSU Handsets occur when the Control Panel is touched during calibration. Such errors can be avoided by waiting for 10 seconds to use the Control Panel after start-up. If your DMUI- HSU Handset is not functioning, a reset may be required. To reset, proceed as follows:

  1. Unplug the DMUI-HSU Handset from the Power Unit.
  2. Wait for 10 seconds.
  3. Plug the DMUI-HSU Handset back to the motor Power Unit
  4. Wait for 10 seconds.
    •  The DMUI-HSU Handset is ready for operation.

DISPOSAL

  • All products in the DM System are subject to the WEEE Directive 2012/19/EU.
  • Dispose of all components separately from household waste. Use designated collection points or disposal companies authorized for this purpose.

LOGICDATA

Electronic & Software Entwicklungs GmbH

LOGICDATA North America, Inc

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals