LOGICDATA DMDinline D Height Adjustable Desks Components Instruction Manual
- June 17, 2024
- LOGICDATA
Table of Contents
- DMDinline D Height Adjustable Desks Components
- INTRODUCTION
- SAFETY
- PRODUCT
- DELIVERY SCOPE
- UNPACKING
- ASSEMBLY
- SOFTWARE-DEPENDENT FUNCTIONS
- INTELLIGENT SYSTEM PROTECTION (ISP)
- DISASSEMBLY
- MAINTENANCE
- TROUBLESHOOTING
- ADDITIONAL INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DOCUMENT VERSION 1.0
OKTOBER 2023
DMDinline D Manual
DMDinline D Height Adjustable Desks Components
DMDinline D Operating Manual
Document Version 1.0 / Oktober 2023
This document was originally published in English.
LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: | +43 (0) 3462 51 98 0 |
---|---|
Fax: | +43 (0) 3462 51 98 1030 |
Internet: | www.logicdata.net |
Email:” | office.at@logicdata.net |
INTRODUCTION
The product documentation consists of this manual and a datasheet.
This document is intended to enable the assembly personnel to work safely with
the DMDinline D actuator.
The assembly personnel must therefore always have the complete documentation
available. The document must be complete and in a perfectly legible condition.
Follow the instructions in this document to avoid hazards and to prevent
damage to the DMDinline D.
The information in this document has been compiled with great care. We strive
to ensure the accuracy and completeness of the content by revising it and
updating it regularly, however, no guarantee can be given for its accuracy and
completeness.
1.1 COPYRIGHT
© September 2023 by LOGICDATA Electronic und Software Entwicklungs GmbH. All
rights reserved, except for those listed in Chapter 1.2 Royalty-free use of
images and text on page 5.
1.2 ROYALTY-FREE USE OF IMAGES AND TEXT
After purchase and full payment of the product, all text and images in Chapter
2 “Safety”, may be used free of charge by the customer. They should be used to
prepare end user documentation for HeightAdjustable Table Systems.
The license does not include logos, designs, and page layout elements
belonging to LOGICDATA. The transfer of this license to third parties without
permission from LOGICDATA is excluded. Full ownership and copyright of the
text and graphics remain with LOGICDATA. Texts and graphics are offered in
their current state without warranty or promise of any kind.
1.3 TRADEMARKS
Documentation may include the representation of registered trademarks of goods
or services, as well as information about copyright or other proprietary
expertise of LOGICDATA or third parties. In all cases, all rights remain
exclusively with the respective copyright holder. LOGICDATA® is a registered
trademark of LOGICDATA Electronic & Software GmbH in the USA, the European
Union, and other countries.
1.4 SYMBOLS AND SIGNAL WORDS USED
Safety Notices contain both symbols and signal words. The signal word
indicates the severity of the hazard.
WARNING| Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
---|---
CAUTION| Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE| The label NOTICE indicates a situation that will not lead to personal
injury, but could lead to damage to the product or the environment.
NOTICE| Damage due to electrostatic discharge (ESD)
SAFETY
2.1 GENERAL SAFETY REGULATIONS AND OBLIGATIONS
In general, the following safety regulations and obligations apply when
handling the product:
- The DMDinline D actuator may only be operated in a clean and perfect condition.
- Do not remove, change, bridge or bypass any protection, safety or monitoring equipment.
- Do not convert or modify the DMDinline D actuator without written approval from LOGICDATA.
- In the event of malfunction or damage, the DMDinline D actuator must be replaced immediately.
- Do not attempt to repair the acuator yourself.
- Hardware replacement is only allowed in a de-energized state.
- For the operation of the system, the national worker protection conditions and the national safety and accident prevention regulations apply.
WARNING Hazard from electric shock
The LOGICleg is designed as IEC Class III equipment. Unauthorised use of
voltages higher than those specified than will result in death or serious
injury from electric shock, fire or other malfunctions. See Nameplate or
Datasheet for detailed information.
- Use only within the rated voltage range
- Use only with the manufacturer‘s original parts
2.2 QUALIFIED PERSONS
The DMDinline D may only be installed and commissioned by qualified persons
who are authorized for installation planning, installation, commissioning or
maintenance/servicing and who have read and understood the DMDinline D
documentation. Qualified persons have the necessary expertise to test, assess
and manage electrical and mechatronic products and systems in accordance with
the generally accepted standards and guidelines of electrical engineering and
furniture manufacturing through their education, work experience and recent
professional activity.
They know and adhere to the basic regulations on occupational safety and
accident prevention and the basic norms and specialist standards applicable to
the specific application.
2.3 LIABILITY
The products comply with the applicable state of the art health and safety
regulations. Nevertheless, dangers can result from incorrect operation or
misuse.
LOGICDATA is not liable for damages caused by:
- Improper use of the products
- Disregard of the documentation
- Unauthorized changes to the products
- Improper work on and with the DMDinline D
- Operating a damaged product
- Wear parts
- Improperly performed repairs
- Unauthorized, improper change of operating parameters
- Disasters, external influence and force majeure
Responsible for the LOGICDATA products in the specific application and compliance with the relevant directives, standards and laws is the manufacturer of the height-adjustable tables in which the LOGICDATA products are installed. LOGICDATA shall not be held liable for any damage that is directly or indirectly attributable to the delivery, performance or use of this document. Each reseller must take into account the relevant safety standards and guidelines for his product in which the DMDinline D is installed.
PRODUCT
3.1 DESCRIPTION
The DMDinline D is an actuator for electrically height-adjustable tables. It
is installed by the customer in a column for electrically height-adjustable
tables. It is controlled by a control unit from LOGICDATA, to which different
hand switches can be connected. Several drives can be operated synchronously
on one control unit.![LOGICDATA DMDinline D Height Adjustable Desks Components
- DESCRIPTION](https://manuals.plus/wp-content/uploads/2024/02/LOGICDATA- DMDinline-D-Height-Adjustable-Desks-Components-DESCRIPTION.png)Fig. 1: DMDinline D
1 | Attachment point on motor end (screws and rubber discs provided) |
---|---|
2 | Connection cable |
3 | Motor |
4 | Attachment point middle tube with installation variant – thick end up |
5 | Attachment point middle tube with installation variant – thick end down |
6 | Flange attachment point |
3.2 INTENDED USE
The DMDinline D actuator may only be installed in telescopic tubes to adjust
electrically height-adjustable tables and used for this purpose exclusively.
The intended use is to adjust the table height electrically. Only power supply
units from LOGICDATA, which are parameterized for the DMDinline D, may be used
for this purpose. The actuators must be assembled, commissioned and
functionally checked by qualified personnel. Any other use that does not
conform to the intended use will result in the loss of warranty and warranty
claims. The basic function is the upward and downward movement (of a table
top). This function can be executed with suitable hand switches from
LOGICDATA.
NOTICE Permissible drive loads and speeds always refer to the product
DMDinline D and not to the additional load on the table system. The reseller
must take additional loads such as e.g. friction forces, the deadweight of the
table components and torque loads into consideration. The newly determined
permissible load must be specified in the parent documentation of the final
product.
DELIVERY SCOPE
The standard scope of delivery for the DMDinline D actuator consists of the following components: Standard delivery scope
1 | DMDinline D actuator |
---|---|
2 | Two mounting screws incl. rubber disks (LOG-PRT-SD-MOUNTINGSCREW) |
UNPACKING
The DMDinline D actuator is packaged in a carton.
NOTICE
Ensure proper ESD handling during unpacking. Errors that can be attributed
to electrostatic discharge will void warranty claims
To unpack, proceed as follows:
- Remove the packaging material from the drive components.
- Check the contents of the package for completeness and damage.
- Provide the operating manual to the operating personnel.
- Dispose of the packaging material.
NOTICE Dispose of the packaging material in an environmentally friendly manner (separate the plastic parts and the cardboard by type).
ASSEMBLY
6.1 GENERAL ASSEMBLY
NOTICE| Before assembly and operation, the DMDinline D must be acclimatised to
the ambient conditions.
---|---
NOTICE| Ensure proper ESD handling throughout the installation. Failures that
can be attributed to electrostatic discharge will void warranty claims.
CAUTION| Safety shoes and gloves must be worn during the assembly of the
actuator.
6.1.1 ACTUATOR DIMENSIONS
Figure 3 shows the dimensions of the DMDinline D actuator in the retracted and
extended state. Fig. 3: a retracted length, b installation length, c extended
length
6.1.2 INSTALLATION OPTIONS
The DMDinline D is designed for synchronous movement of the middle tube. Fig.
4: Synchronous movement of the middle tube results in the distances x being
the same at all times independently from the current height (middle tube
removed for easier demonstration).
For this it is necessary to connect the drive with the middle tube of the
height-adjustable column. Depending on the type of height-adjustable column
design, different installation requirements must be taken into consideration.
In this document, the installation variants are characterized as follows,
depending on the types of height-adjustable columns:
- “Thick end up”: In this variant, the tube with the largest diameter is at the top (table top).
- “Thick end down”: In this variant, the tube with the largest diameter is at the bottom (floor).
The DMDinline D actuator can be used for both variants.Fig. 5: “Thick end up” (left) and “Thick end down” (right) in retracted position
NOTICE| Regardless of the installation variant, the inner diameter of the
inner tube must be selected so that a surrounding air gap of min 3 mm between
the inner wall of the tube and the DMDinline D is guaranteed.
---|---
NOTICE| As shown in Figure 5, height-adjustable columns must be designed so
that the motor end of the DMDinline D is always up
6.1.3 INSTALLATION TOLERANCES
NOTICE
In order to ensure proper functioning, height-adjustable columns must comply
with the tolerances specified by LOGICDATA. Otherwise, the warranty claims are
void.
These tolerances are published by LOGICDATA on request.
6.1.4 DEFAULT SETTINGS
NOTICE | Failure to follow the instructions below may result in damage! |
---|---|
NOTICE | LOGICDATA recommends measuring the dimensions of the DMDinline D |
before assembly with a gauge or other suitable measuring equipment.
NOTICE| In order to utilize the complete stroke of the drive, a corresponding
design of the height-adjustable column is necessary. It is important that the
drive reaches the final position before the tube.
NOTICE| Deviating flange settings may only be implemented in consultation with
LOGICDATA.
6.2 ASSEMBLY “THICK END UP” VARIANT
This chapter explains the installation with installation option “thick end up”
in more detail. If you are using the installation of the “thick end down”
column, skip this chapter and continue with 6.3.
6.2.1 ATTACHING THE MIDDLE TUBE
The tube adapter is intended to connect the drive with the middle tube of the
height-adjustable column via a special counterpiece (see Figure 6: Symbolic
image of the counterpiece for the tube adapter).
NOTICE| The design specifications for the customer-provided counterpiece
are available from LOGICDATA only on request. These includes dimensions and
tolerances as well as notes on material selection and assembly.
---|---
CAUTION| Danger due to insecure connection
To ensure a secure connection, the counterpiece must be designed exactly to
the specifications of LOGICDATA. Otherwise, the warranty claims are void.
Fig. 6: Symbolic image of the counterpiece for the tube adapter
Recommended assembly procedure:
NOTICE| The assembly procedure shown is based on a height-adjustable column
design in which the top plate can be removed (i.e., it is not permanently
connected to the thick end). For instructions on mounting with other height-
adjustable column constructions, please contact LOGICDATA.
---|---
NOTICE| We recommend measuring the friction of the tube pairs before
installing the drive! The combination of control unit and drive is not a
suitable means for measuring the friction!
Proceed with the following steps for the assembly with the installation variant “thick end up”:
-
Assemble the counterpiece for the tube adapter (see Figure 6: Symbolic image of the counterpiece for the tube adapter) in the middle tube.
-
Insert the three tubes into each other.
NOTICE
LOGICDATA recommends measuring the gliding properties of the height- adjustable column without the installed drive after this step.
NOTICE
The maximum force on the tube adapter counterpart must not exceed 150N! This is due to a difference in frictional forces be tween the tube pairs. -
Mount the drive in the preassembled height-adjustable column (see Figure 7: Example of actuator installation in a round height-adjustable column by rotationg it 1/8 turn clockwise when seen from top).
-
Then make the attachment on the motor end and flange end according to Chapter 6.4 and Chapter 6.5.
Fig. 7: Example of actuator installation in a round height-adjustable
column
6.3 ASSEMBLY “THICK END DOWN” VARIANT
The middle tube adapter is produced by the customer and is fixed in the middle
tube. It is connected to the drive in the installation variant “thick end
down”.
NOTICE| The design specifications for the middle tube adapter are available
from LOGICDATA only on request. These includes dimensions and tolerances as
well as notes on material selection and assembly.
---|---
** CAUTION| Danger due to insecure connection**
To ensure a secure connection, the middle tube adapter must be designed
exactly to the specifications of LOGICDATA. Otherwise, the warranty claims are
void.
Recommended assembly procedure:
NOTICE| The assembly procedure shown is based on a height-adjustable column
design in which the top plate can be removed (i.e., it is not permanently
connected to the inner tube). For instructions on mounting with other height-
adjustable column constructions, please contact LOGICDATA.
---|---
NOTICE| We recommend measuring the friction of the tube pairs before
installing the drive! The combination of control unit and drive is not a
suitable means for measuring the friction!
Proceed with the following steps for the assembly with the installation variant “thick end down”:
-
Assemble the middle tube adapter (see Figure 8: Symbolic image of the middle tube adapter) in the middle tube.
-
Insert the three tubes into each other.
NOTICE
For suitable production aids, joining forces and joining speeds or detailed information on the assembly process, please contact LOGICDATA. Failure to perform the joining process properly may result in damage to the DMDinline D. Fig. 9: Assembling the middle tube -
Insert the actuator into the column. With the middle tube attachment point fitted in the middle tube adapter, turn it 90 degrees in any direction.
-
Attach at the motor end and flange end according to Chapter 6.4 and Chapter 6.5.
6.4 MOTOR SIDE INTERFA CE
NOTICE| The design specifications for the top plate are available from
LOGICDATA only on request. These includes dimensions and tolerances as well as
notes on material selection and assembly.
---|---
NOTICE| The screws and rubber disks are supplied together with the drive. The
mounting screws must be tightened to the recommended tightening torque of 2.5
– 3 Nm.
NOTICE| The DMDinline D can only be mounted once with the supplied screws,
otherwise correct tightening of the mounting screws can not be guaranteed.
NOTICE| Mounting without rubber disks is not permitted.
CAUTION| Danger due to insecure connection
To ensure a secure connection, the top plate must be designed exactly to the
specifications of LOGICDATA. Otherwise, the warranty claims are void.
6.5 FLANGE SIDE INTERFACE
The figure below provides an overview of the components required to assemble
the drive on the flange end. Fig. 10: Overview of the flange end
1 | Mounting screw (adapted by the customer to bottom plate) |
---|---|
2 | Bottom plate (developed by the customer, design specifications of |
LOGICDATA)
3| Flange adjustment point
NOTICE
The design specifications for the bottom plate are available from LOGICDATA
only on request. These includes dimensions and tolerances as well as notes on
material selection and assembly.
CAUTION
Danger due to insecure connection
To ensure a secure connection, the top plate must be designed exactly to the
specifications of LOGICDATA. Otherwise, the warranty claims are void.
6.6 CABLE CONNECTION
After the DMDinline D is installed in the height-adjustable column, connect
the motor cable to the actuator.
Be careful not to damage the cable when installing the finished column.
SOFTWARE-DEPENDENT FUNCTIONS
The description of the software-dependent functions can be found in the Dynamic Motion System manual.
INTELLIGENT SYSTEM PROTECTION (ISP)
ISP (Intelligent System Protection) reduces the risk of pinching when a moving
table hits an obstacle. It is important that all actuators of a table are
either with or without ISP sensors. For more information concerning ISP, refer
to the Dynamic Motion System
Manual.
DISASSEMBLY
For disassembly, disconnect the DMDinline D from the power supply and proceed in reverse order to assembly.
MAINTENANCE
WARNING| Hazards from the use of incorrect accessory parts
Only use original accessory parts. These may only be installed by expert
service personnel. Otherwise your warranty claims will be void.
---|---
WARNING| Hazard from inappropriate repairs
Contact your customer service immediately in the event of a malfunction. Only
original spare parts are approved for the repair of the drives. These may only
be replaced by expert service personnel. Otherwise your warranty claims will
be void.
TROUBLESHOOTING
Please refer to the Dynamic Motion Manual for troubleshooting DMDinline
actuators.
For technical problems, please contract our support at:
Phone: | +43 (0) 3462 51 98 0 |
---|---|
Fax: | +43 (0) 3462 51 98 1030 |
Email: | office.at@logicdata.net |
Always provide the product name and the revision status according to the type
plate with any support request.
In case of a defect, replace the DMDinline D as a whole.
ADDITIONAL INFORMATION
12.1 TECHNICAL SPECIFICATIONS
You can find the technical data of your actuator in the corresponding data
sheet.
12.2 OPTIONAL PRODUCTS
NOTICE You can find information about available optional products in the
current product catalog and at www.logicdata.net
12.3 DISPOSAL
**** Dispose of all components separately from household waste. Use
designated collection points or disposal companies authorized for this
purpose.
LOGICDATA
Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: +43 (0)3462 5198 0
Fax: +43 (0)3462 5198 1030
E-mail: office.at@logicdata.net
Internet: http://www.logicdata.net
LOGICDATA North America, Inc.
13617 Woodlawn Hills Dr.
Cedar Springs, MI 49319 USA
Phone: +1 (616) 328 8841
E-mail: office.na@logicdata.net
www.logicdata.net
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>