Clinton Electronics CE-CPUJB Universal Junction Box for Telescoping Camera Poles Installation Guide
- May 15, 2024
- Clinton Electronics
Table of Contents
CE-CPUJB(B) Install Guide
CE-CPUJB Universal Junction Box for Telescoping Camera Poles
Included Items:
• Junction Box
• 3/8″-16 Carriage Bolt x1
• 3/8″-16 Lock Nut x1
• 2″ Fender Washer x1| • 5mm Allen Wrench x1
• 3mm Allen Wrench x1
• 36″ Safety Cable x1
• Instructions
---|---
Required Items:
- Camera Pole
- 3/4″ Conduit & Fittings
- 9/16″ Wrench
- Phillips Head Screwdriver
CAUTION!
USE ONLY AS DESIGNED. This product is designed to serve as a mounting
apparatus between a camera pole mount and the ceiling structure (steel support
truss or channel strut). It is not designed to mount to a wooden or drywall
surface. Refer to the camera pole installation guide for details on installing
the camera pole. It is intended for use only with the maximum weight
indicated. Use with products heavier than the maximum weights indicated may
result in instability causing possible injury.
Maximum Load Capacity: 15 lbs/ 6.8 kgs
INSERT TOP BOLT
Insert the included carriage bolt into the square center hole of the CE-CPUJB junction box housing.
SECURE TO CEILING STRUCTURE
Guide the carriage bolt between the gap n the ceiling truss or channel strut. Place the fender washer and lock nut onto the bolt and tighten with a 9/16″ wrench.
CONNECT CONDUIT
Choose the desired wire/conduit hole ocation(s), then connect conduit and conduit adapters/fittings (not ncluded).
CHOOSE SWIVEL OPTION
No Swivel: Fully tighten the four Phillips head screws to the retaining
plate.
Then fully tighten the external set screw with the included 3mm Allen wrench.
Swivel: Leave the four Phillips head screws only partially
tightened, and do not tighten the external set screw- this will allow the
swivel ball to move freely. The ooser the screws, the more freely the swivel
ball will move.
ATTACH COVER PLATE
Feed wiring/cabling from conduit and junction box through the top of the ball and cover plate assembly. Place the cover plate assembly onto the junction box and securely tighten the 4 Allen-head screws with the ncluded Smm Allen wrench.
CONNECT CAMERA POLE
Feed cabling through the top of the camera pole and out through the bottom of the camera pole. The top of the camera pole is the end with the larger diameter tubing, the bottom of the camera pole has the smaller diameter tubing with the flared end. Attach the camera pole and 36″ safety cable to the swivel ball using the hardware from the camera pole. The stepped swivel ball receiver s compatible with all Clinton Telescoping Camera poles. Ensure the safety cable is looped around a secure section of the ceiling structure. Refer to the separate camera pole manual for final assembly of camera pole.
*6701 Clinton Road Loves Park, L 61111
800.549.6393 (Support)
www.clintonelectronics.com
v.11.07.23
Information in this document is subject to change without notice**
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>