Clinton Electronics CE-VX180X2QHD Dual Camera Installation Guide
- June 9, 2024
- Clinton Electronics
Table of Contents
- Clinton Electronics CE-VX180X2QHD Dual Camera Installation Guide
- CE-VX180X2QHD(B) Install Guide
- Required Items:
- Optional Items:
- la. DISASSEMBLE
- lb. DISASSEMBLE
- 2. MOUNT OUTER CASE
- 3. CONNECT CABLES
- 4a. ATTACH CAMERA
- 4b. ATTACH CAMERA
- 5. TEST MONITOR/ OSO CONTROL
- Ba. CAMERA ANGLE ADJUSTMENT
- 6b. CAMERA ANGLE ADJUSTMENT
- 7. REPLACE DOME COVER
- B. REASSEMBLE
- 9. PERIODIC DOME CLEANING
- COMMON INSTALLATIONS
- AVOID INSIDE CORNERS
- AVOID DIRECT SUNLIGHT
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Clinton Electronics CE-VX180X2QHD Dual Camera Installation Guide
CE-VX180X2QHD(B) Install Guide
- Included Items:
- Dual 18D’ VX Dome Camera x 1 • Mounting Screws x 4
- Torx Wrench (T20 Security) x 1 • Drywall Anchors x 4
- Instructions x 1
- Test Monitor BNC Lead x 1
Required Items:
- Phillips Head Screwdriver or Drill with Phillips Head Bit
- DC12V or AC24V Power Supply
Optional Items:
- CE-REMOTE (OSD Remote Control)
la. DISASSEMBLE
Use the supplied Torx wrench to loosen the 3 Torx screws that hold the dome
assembly onto the base.
Remove the top dome cover from the camera base.
lb. DISASSEMBLE
Remove the four Phillips head screws that hold the inner case onto the camera base, then remove the inner camera assembly from the camera base. Keep these 4 screws for final assembly.
2. MOUNT OUTER CASE
If mounting to a solid surface, use the four Phillips head mounting screws
and, if necessary, drywall anchors.
If mounting to a conduit box, choose the best mounting hole pattern for your
style of box and use the appropriate screws. There are numerous mounting hole
patterns available to accommodate various box types. To connect 3/4″ EMT
conduit to the outer case, a 3/4″ EMT conduit adapter can also be used (not
included). Thread the adapter into the bottom/center hole of the case or the
hole on the side
3. CONNECT CABLES
Make video connections to the appropriate BNC cables and connect to power. Each camera will have two video outputs. The cables with the SILVER sleeve are for the camera with the SILVER thumb screw. The BLACK and GOLD BNC connectors are for 4MP EX-SDI output, while the GREEN and SILVER BNC connectors are for HD Analog / Analog output.
Feed any cable slack into the mounting surface. A Power LED (on the circuit board) will illuminate GREEN when the camera is receiving correct power. If the LED indicator is blinking or solid red, refer to the table above and make the necessary power adjustments.
4a. ATTACH CAMERA
Reassemble the inner camera assembly into the mounting base as shown below.
Align the key on the lip of the inner camera assembly with the slot on the
camera base when reassembling. If these are not aligned properly the weather
resistant seal will be compromised, allowing water to leak into the camera.
ATTENTION If the key & slot are not aligned properly, the weather resistant seal will be compromised, allowing water to leak into the camera.
4b. ATTACH CAMERA
Reinstall the four Phillips head screws that were removed in step lb which
hold the inner case to the camera base.
The four holes are marked with arrowheads
5. TEST MONITOR/ OSO CONTROL
To test the camera with a test monitor use either the supplied Test Monitor
BNC Lead or optional CE-REMOTE. The
Test Monitor BNC Lead plugs into the small, 2-Pin Connector (marked CN2) next
to the wide, 8 wire connection on the circuit board. The CE-REMOTE plugs into
the DIN Port.
To change from Camera 1 to Camera 2 for test monitor viewing: locate the blue
dip-switch next to the DIN Port, then slide left or right to change cameras.
OSD adjustments can be made by using the OSD Joystick or the optional CE-
REMOTE. Refer to OSD Manual for detailed instructions on adjusting camera
settings.
The image from the camera can be digitally zoomed in before entering the camera’s OSD menu by pushing the ‘UP’ button on the CE-REMOTE (pressing ‘DOWN’ will zoom out the image). When the camera is set to 4MP the maximum zoom level is xl4, and when the camera is set to 2MP the maximum zoom level is x8.
NOTICE The test monitor connection on the CE-REMOTE and the 2-pin connector on
the camera board will match the Analog output type from the camera. If the
camera is set to an HD
Analog option, ensure the test monitor will support that signal type.
Ba. CAMERA ANGLE ADJUSTMENT
Adjust the angle of the camera as necessary.
NOTICE The center thumb screws should not be loosened. They don’t allow any additional tilt adjustment.
6b. CAMERA ANGLE ADJUSTMENT
Depending on the desired angle of view or how the camera is installed (ceiling or wall mount), the camera modules may need to be rotated 90 degrees. To rotate the camera module, first loosen the two thumb screws on the face of the camera, then rotate as necessary and tighten the thumb screws to secure. The thumb screws should be aligned “vertically” for correct image. If the image needs to be rotated 180 degrees, go to the camera’s OSD menu and select Main Menu > Special > Rotate.
7. REPLACE DOME COVER
Remove any protective film from the outer and/or inner dome. Carefully install the dome cover onto the camera base. Rotate the dome mask as needed if the cut-outs in the dome mask do not align with the camera lenses.
B. REASSEMBLE
Using the supplied Torx wrench, tighten the 3 Torx screws that hold the dome cover onto the base. Make sure each screw is tight to ensure superior weather resistance.
9. PERIODIC DOME CLEANING
Over time, dome cameras will collect dirt and dust on the outside of the
polycarbonate dome bubble- often resulting in blurry/out of focus images. We
recommend periodically cleaning the dome to ensure optimal day and night image
quality.
To clean the outside of the dome: first use compressed air to blow off any
significant amounts of dirt/dust – then use warm, soapy water and a damp
micro-fiber cloth towel to clean. Dry with a separate, clean micro-fiber cloth
towel.
Glass cleaner, Ammonia, alcohol and/or other solvents should never be used to
clean the dome. These products contain harsh chemicals that can cause
corrosion and reduce optical clarity. Paper towels, shop-rags, or other rough
fabric should also never be used to dry the dome as they can scratch the dome.
COMMON INSTALLATIONS
For an optimal unobstructed field-of-view, install the CE-VX180X2QHD camera in the center of a wall or ceiling. Outside corners can also provide wide, open views. Use the CE-UCB-CRNR (sold separately) to mount the camera to an outer corner.
AVOID INSIDE CORNERS
If installing on an inside corner, it’s best to move the camera away from the corner a few feet to avoid the corner walls from taking up the majority of the scene and to lessen the heavy fisheye distortion effect.
AVOID DIRECT SUNLIGHT
Inside Corner
The convex design of the 180′ makes the camera prone to lens flares caused by
direct sunlight. Lens flares can occur even if the lens does not directly
point at the bright light source. The result is an over-exposed portion of the
image. To reduce lens flare, angle the camera down and away from the bright
light source or install it higher up to increase the downward angle.