clinton electronics VX Series Vandal X Outdoor Dome Camera Installation Guide
- June 9, 2024
- Clinton Electronics
Table of Contents
- clinton electronics VX Series Vandal X Outdoor Dome Camera Installation
- VX Series Install Guide
- DISASSEMBLE
- MOUNT OUTER CASE
- CONNECT CABLES
- TEST MONITOR/ OSO CONTROL
- CAMERA ANGLE ADJUSTMENT
- REASSEMBLE
- PERIODIC DOME CLEANING
- HD ANALOG Install Tips
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
clinton electronics VX Series Vandal X Outdoor Dome Camera Installation
VX Series Install Guide
For HD Analog (Non-lR LED) Vandal X Outdoor Dome Cameras
Included Items
- Vandal X Series Dome Camera x 1
- Torx Wrench (T20 Security) x 1
- Instructions x 1
- Focusing Tool (CE-VX60 only) x 1
- Test Monitor BNC Lead x 1
- Mounting Screws x 4
- Drywall Anchors x 4
Required Items:
- Phillips Head Screwdriver or Drill with Phillips Head Bit
- DC12V or AC24V Power Supply
Optional Items:
- CE-REMOTE (OSD Remote Control)
DISASSEMBLE
- la. Use the supplied Torx wrench to loosen the 3 Torx screws that hold the dome assembly onto the base. Remove the top dome cover from the camera base.
- lb.Remove the four Phillips head screws that hold the inner case onto the camera base, then remove the inner camera assembly from the camera base. Keep these 4 screws for final assembly.
MOUNT OUTER CASE
If mounting to solid surface, use the four Phillips head mounting screws &
drywall anchors if necessary.
If mounting to a conduit box, choose the mounting hole pattern that best suits
your application and use the appropriate screws. Multiple mounting hole
patterns are provided.
CONNECT CABLES
Make connections to the BNC cable and the power connection. Feed any cable slack into the mounting surface. A Power LED (on the circuit board) will illuminate GREEN when the camera is receiving correct power. To ensure quality operation, verify proper BNC and power termination, along with proper voltage at camera.
ATTACH CAMERA
-
Replace the inner camera assembly into the mounting base as shown below.
Align the key on the lip of the inner camera assembly with the slot on the camera base when reassembling. If these are not aligned properly the weather resistant seal will be compromised, allowing water to leak into the camera. ATTENTION: IF THE KEY & SLOT ARE NOT ALIGNED PROPERLY, THE WEATHER RESISTANT SEAL WILL BE COMPROMISED, ALLOWING WATER TO LEAK INTO THE CAMERA. -
Replace the four Phillips head screws that hold the inner case to the camera base. The four holes are marked with arrowheads.
TEST MONITOR/ OSO CONTROL
To test the camera with a test monitor use either the supplied Test Monitor BNC Lead or optional CE-REMOTE. The Test Monitor BNC Lead plugs into the small, 2 PIN connector (marked CN2) next to the wide 12 wire connection on the circuit board. The CE-REMOTE plugs into the DIN Port. OSD Adjustment can be made by using the OSD Joystick or the optional CE-REMOTE. Refer to OSD Manual for detailed instructions on adjusting camera settings.
NOTE
The test monitor connection on the CE-REMOTE and the 2-pin connector on the
camera board will match the output from the main Analog connector. If the
camera is set to an HD Analog option, ensure the test monitor will support
that signal type.
CAMERA ANGLE ADJUSTMENT
Adjust the angle of the camera as necessary.*If the camera image is upside-dawn and needs tu be flipped/rutated, it may be easier tu ffip/rutate the image via the asa Menu: (Main Menu/Special/Butate). Refer tu asa manual fur mare infurmatiun.
ZDDM / FOCUS ADJUSTMENT: Camera models w/ 2.8-12mm Lens
Loosen the appropriate adjustment lever by turning counter-clockwise. To widen
the viewing angle (zoom the image out), rotate the ZOOM lever to the RIGHT
(Counter-clockwise). To narrow the viewing angle (zoom the image in). rotate
the ZOOM lever to the LEFT (Clockwise). Adjust the focus near or far as needed
by moving the FOCUS lever Left or Right to focus the lens.
After zoom I focus adjustments have been made, tighten the adjustment levers
to lock the adjustments.
*Lens shown and adjustments may vary depending on camera model.
FOCUS ADJUSTMENT: CE-VX6D(B) w/ 6-5□mm lens
With a test monitor attached, place the supplied focus adjustment tool
approximately 1/2″ in front of the lens (concave side in), to simulate the
dome being attached. Adjust the lens as needed to achieve proper focus. If the
focus tool is not used, the image will be blurry/out of focus when the dome
cover is attached.
REASSEMBLE
Carefully install the dome cover onto the camera base. If the cut-out in the
dome mask does not align with the lens of the camera, rotate the dome mask
using the finger tab located directly under the cut-out. Using the
supplied Torx wrench, tighten the 3 Torx screws that hold the dome cover onto
the base. Make sure each screw is tight to ensure superior weather resistance.
ATTENTION
IF TORX SCREWS AREN’T FULLY TIGHTENED THE WEATHER RESISTANT SEAL WILL BE
COMPROMISED, ALLOWING WATER TO LEAK INTO THE CAMERA.
PERIODIC DOME CLEANING
- Over time, dome cameras will collect dirt and dust on the outside of the polycarbonate dome bubble- often resulting in blurry/out of focus images. We recommend periodically cleaning the dome to ensure optimal day and night image quality.
- To clean the outside of the dome: first use compressed air to blow off any significant amounts of dirt/dust – then use warm, soapy water and a damp micro-fiber cloth towel to clean. Dry with a separate, clean micro-fiber cloth towel.
- Glass cleaner, Ammonia, alcohol and/or other solvents should never be used to clean the dome. These products contain harsh chemicals that can cause corrosion and reduce optical clarity. Paper towels, shop-rags, or other rough fabric should also never be used to dry the dome as they can scratch the dome.
HD ANALOG Install Tips
This camera’s default Analog video output is set to: CVBS
HD Analog Compatibility
While Analog (CVBS) and HD Analog (T VI, C VI, A_HD) share the same type of
connectors, they’re different signal types that are not compatible with each
other.
Because there are signal tuning variations between each HD Analog DVR
manufacturer- we can not guarantee that the HD Analog output from the camera
will display correctly with off-brand equipment
HD Analog Output Through the OSD Menu
Before changing the HD Analog output of the camera, check the compatibility of
the DVR to ensure that it can accept the desired camera output Selecting an
incorrect HD Analog output from the camera can result in poor video quality or
no video on the DVR
To change the HD Analog Output: Enter the OSD Menu of the camera, then access
the SYSTEM Menu. Select the desired HD Analog Output using left or right
(CVBS, A_HD, T_VI, or C_VI).
Changing the HD Analog Output here also affects the analog test monitor
outputs on the CE-REMOTE and the 2-pin test monitor connec- tion located on
the camera board.
HD Analog Output Using the Joystick
Move and Hold the OSD Joystick in the desired direction (Up, Down, Left, Right) for 3 seconds to change the output signal type.
- Up: A_HD
- Down: CVBS (default)
- Left: C_VI
- Right: T_VI
HD Analog Distance
HD Analog signals degrade with long runs of cable. The image can appear washed
out and lacking color saturation (black & white).
If you need further help call Clinton Electronics Technical Support at
B00-549-6393.
*Information in this document is subject to change without notice
Read User Manual Online (PDF format)