Clinton Electronics VX IR Series Vandal X Outdoor Dome Camera Installation Guide
- June 9, 2024
- Clinton Electronics
Table of Contents
V X I R Series Install Guide
For I R Equipped Analog & H D Analog Vandal X Outdoor Dome Cameras
Installation Guide
VX IR Series Vandal X Outdoor Dome Camera
Included Items
- Vandal X Series Dome Camera x1»
- Torx Wrench (T20 Security) x1
- Instructionsx 1
- Test Monitor BNC Lead x 1
- Mounting Screws x 4
- Drywall Anchors x 4
Required Items:
- Phillips Head Screwdriver or Drill with Phillips Head Bit
- DCI2V or AC24V Power Supply
Optional Items:
- CE-REMOTE ( OSD Remote Control)
la. DISASSEMBLE
Use the supplied Torx wrench t o loosen the 3 Torx screws that hold the dome
assembly onto the base. Remove the top dome cover from the camera base.
1b. DISASSEMBLE
Remove the four Phillios head screws that hold the inner case onto the camera
base, then remove the inner camera assembly from the camera base. Keep these 4
screws for final assembly.
MOUNT OUTER CASE
If mounting to solid surface, use the four Phillips head mounting screws &
drywall anchors if necessary.
If mounting to a conduit box, choose the mounting hole pattern that best suits
your application and use the appropriate screws. Multiple mounting hole
patterns are provided.
3/4” EMT conduit can also be attached to the outer case using a threaded 3/4”
EMT conduit adapter (not included).
Connect either to the hole in the bottom/center of the case or the hole on the
side.
CONNECT CABLES
Make connections to the BNC cable and the power connection. Feed any cable slack in to the mounting surface. A Power LED (on the circuit board) will illuminate GREEN when the camera is receiving correct power. To ensure quality operation, verify proper BNC and power termination, along with proper voltage at camera.
Default Analog output: CVBS
Analog Output Selectable: ( CVBS / A _ HD / C_VI/T_VI)
Refer to included “HD ANALOG ” page for information on changing signal
type.
*CE-VX0(B): Analog is Yellow & Silver Connector. H D Analog not available.
RVM – Rated Voltage Monitoring
LED COLOR | STATUS |
---|---|
GREEN | Safe Power |
RED-SOLID | Over 29 Volts (AC24V) |
RED -BLINK | Under 10 Volts (DCI2V) |
4a. ATTACH CAMERA
Replace the inner camera assembly into the mounting base as shown below.
Align the key on the lip of the inner camera assembly with the slot on the
camera base when reassembling. If these are not aligned properly the weather
resistant seal will be compromised, allowing water to leak into the camera.
ATTENTION If the key & slot are not aligned properly, the weather
resistant seal will be compromised, allowing water to leak into the camera.
4b. ATTACH CAMERA
Replace the four Phillips head screws that hold the inner case to the camera
base. The four holes are marked with arrowheads.
TEST MONITOR / OSD CONTROL
To test the camera with a test monitor use either the supplied Test Monitor BNC Lead or optional CE-REMOTE. The Test Monitor BNC Lead plugs into the small, 2 PIN connector (marked CN2) next to the wide 12 wire connection on the circuit board. The CE-REMOTE plugs into the DIN Port. OSD Adjustment can be made by using the OSD Joystick or the optional CE-REMOTE. Refer to OSD Manual for detailed instructions on adjusting camera settings.
NOTICE The test monitor connection on the CE-REMOTE and the 2-pin connector on the camera board will match the output from the main Analog connector. If the camera is set to an HD Analog option, ensure the test monitor will support that signal type.
CAMERA ANGLE ADJUSTMENT
Adjust the angle of the camera as necessary.
A . Lens Rotation: Rotate the notched area on the camera assembly.
B. Lens Angle: Loosen thumb screws on each side to adjust the tilt of the
lens.
C. Camera Plate Rotation: Pinch the gimbal U-Bracket and rotate the camera
assembly on the base.
“if the camera image is upside-down and needs to beflipped/ rotated, it may be
easier to flip/rotate the image via the OSD Menu; (Main Menu/Special/Rotate).
Refer to OSD manual for more information.
7a. ZOOM / FOCUS ADJUSTMENT
The Zoom & Focus levers are located behind the IR cover plate. To access
the levers, press the 2 tabs on either side of the cover. Lift the cover
carefully away from the camera, taking care not to disconnect or damage the
wires for the IR LEDs and I R Sensor.
7b. ZOOM / FOCUS ADJUSTMENT
Loosen the appropriate adjustment lever by turning counter-clockwise. To widen
or narrow the viewing angle rotate the ZOOM lever to the Left or Right. Rotate
the Focus lever Left or Right to focus the lens.
After zoom / focus adjustments have been made, tighten the adjustment levers to lock the adjustments. “Lens shown and adjustments may vary depending on camera model.
IR LED ADJUSTMENT
To adjust the intensity of the IR LEDs, access the camera’s OSD menu with the CE-REMOTE by pressing ‘SETUP’ Scroll down to the DAY&NIGHT option, press ‘SETUP’ to enter the sub-menu.
Refer to OSD Manual for detailed instructions on adjusting camera settings.
ANTISAT: Increase of decrease the overall amount of IR LED saturation.
LED LEVEL: Increase or decrease the intensity/brightness of the IR LEDs.
When set to 0 the IR LEDs are Off.
D >N THRES: Day to Night (Color to B&W) change level. The lower the
number, the lower the lux level. To set
the IR LEDs to turn on later i n the evening (when darker), decrease the
number.
N >D THRES: Night to Day (B&W to Color) change level. The lower the
number, the lower the lux level. To set the camera to change back to color
mode earlier in the morning, decrease the number.
DELAY: Sets a delay time before the switch is made from day to
night/night to day.
NOTICE The DAY&NIGHT setting should be set to EXTERN for normal switching
of day/night modes. If set to AUTO intermittent changing of day/night modes
can occur.
REASSEMBLE
Replace the dome cover onto the camera base. Align the IR S hieldtracks with
the guides on the camera assembly by turning the dome bubble. The cover must
be loose, with no pressure applied, to turn the bubble. cit may be easier to
turn the bubble with the cover removed).
Using the supplied Torx wrench, tighten the 3 Torx screws that hold the dome
cover onto the base. Make sure each screw is tight to ensure superior weather
resistance.
ATTENTION ftorx screws aren’t fully tightened the weather resistant seal will be compromised, allowing water to leak into the camera.
PERIODIC DOME CLEANING
Over time, dome cameras will collect dirt and dust on the outside of the
polycarbonate dome bubble— often resulting in blurry/out of focus images. We
recommend periodically cleaning the dome to ensure optimal day and night image
quality.
To clean the outside of the dome: first use compressed air to blow off any
significant amounts of dirt/dust – then use warm, soapy water and a damp
micro-fiber cloth towel to clean. Dry with a separate, clean micro-fiber cloth
towel.
Glass cleaner, Ammonia, alcohol and/or other solvents should never be used to
clean the dome. These products contain harsh chemicals that can cause
corrosion and reduce optical clarity. Paper towels, shop-rags, or other rough
fabric should also never be used to dry the dome as they can scratch the dome.
“information in this document is subject to change without notice
6701 Clinton Road Loves Park, IL 61111
800.549.6393 (Support)
www.clintonelectronics.com
Documents / Resources
|
Clinton Electronics VX IR Series Vandal X Outdoor Dome
Camera
[pdf] Installation Guide
VX IR Series Vandal X Outdoor Dome Camera, VX IR Series, Vandal X Outdoor Dome
Camera, Outdoor Dome Camera, Dome Camera, Camera
---|---