SAVI Controls QSO-01 Smart Outlet User Guide
- May 15, 2024
- SAVi Controls
Table of Contents
SAVI Controls QSO-01 Smart Outlet
Important Information
WARNING: SHOCK HAZARD Turn OFF the power to the branch circuit for the
outlet at the service panel. All wiring connections must be made with the
POWER OFF to avoid personal injury and/or damage to the outlet. This device is
intended for installation in accordance with the National Electric Code and
local regulations in the United States and the Canadian Electrical Code and
local regulations in Canada.
If you are unsure or uncomfortable about performing the installation, consult
a qualified electrician.
Smart Outlet Wiring/Installation Instructions
-
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT: Verify power is OFF to switch box before continuing. -
Remove wall plate.
-
Remove the switch mounting screws.
-
Carefully remove the outlet from the outlet box.
-
Disconnect the wires from the existing outlet.
-
Label wires according to the previous terminal connection.
-
There are three screw terminals on the outlet, these are marked:
- GROUND – green/bare
- LINE – black (connected to power)
- NEUTRAL – white (the neutral wire is often tied to other neutral wires and may require a jumper cable (not included) to connect with the device.)
-
Match these screw terminals to the wires connected to the existing outlet.
Wire Gauge Requirements
Use 14AWG or larger wires suitable for at least 80ºC for supplying line (hot), neutral, ground, and connections.
- Insert outlet into the box being careful not to pinch or crush wires.
- Secure the outlet to the box using the supplied screws.
- Mount the wall plate.
- Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected device can be turned ON/OFF in two ways.
- Manually from the front SAVI button
- Remote On/Off control
Manual LED Invert Method
- The device needs to be paired with a wireless controller.
- Quickly press the ON/OFF button 10 times
Note: The light will invert if done correctly.
Observe Important Wiring Information
Always follow the recommended wire strip length (5/8in or 16mm) and wiring
combination when making wiring connections.
Consult an electrician with questions or for professional installation. UL
specifies the tightening torque for the screws is 14 Kgf-cm (12 lb.-in).
IMPORTANT: The screw terminals in this receptacle are intended to only be used with copper wire. Consult a qualified electrician if you have aluminum wiring. Insert wires into holes, do not wrap wires around screws. Do not remove screws.
LEGAL
Resistive/Incandescent/Halogen: 15A (1800W) Motor: 1/2 HP
Operating Ambient Temperature: 0-40C
FOR INDOOR USE ONLY
FCC
Supplier’s Declaration of Conformity 47 CFR 2.1077 Compliance Information
Model: QSO-01
Responsible Party – US Contact Information 2520 Marsh Lane, Carrollton, TX
75006-2401 214-785-6510
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications or changes to this
equipment. Such modifications or changes could void the user’s authority to
operate the equipment.
Please visit savicontrols.com to find the full
FCC/IC statements.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of
20cm between the radiator and any part of your body.
IC
This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with ISED RSS-102 radiation exposure limits set forth
for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of
20cm between the radiator and any part of your body.
Le présent appareil est conforme aux CNR d’ Industry Canada applicables aux appareils radio exempts de licence. L ‘exploitation est autorisée aux deux conditions suivantes:
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la normed NMB-003 du
Canada
Customer Support
hellosavi.com
©2023 SAVI Controls Rev 10/27/23
References
- SAVI I Hello Simplicity I Commercial AV Designer and Manufacturer
- SAVI I Hello Simplicity I Commercial AV Designer and Manufacturer
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>